Brand:

Rosemount 08712-0060-0001 Coil Drive Cable 14 AWG

Description

What 08712-0060-0001 does in a magmeter loop

A magnetic flowmeter creates its measurement by passing current through coils that generate a magnetic field across the pipe. Rosemount 08712-0060-0001 is the cable that carries that coil current from a remote transmitter to the sensor. The datasheet identifies it as Coil Drive Cable, 14 AWG, equivalent to Belden 8720 or Alpha 2442, sold by the foot. The metric-length twin is 08712-0060-2003. Because the coil drive conductor carries far more current than the signal pair, it is a heavier gauge than the 20 AWG electrode cable.

Think of the pair as power and signal: this cable supplies the field, and the electrode cable brings back the voltage that the field induces in the moving liquid.

Cable and system data

Parameter Value
Part number 08712-0060-0001
Description Coil Drive Cable (14 AWG), per foot
Cable equivalent Belden 8720, Alpha 2442
Metric twin 08712-0060-2003
Conductor size 14 AWG
Length range 5 to 1000 ft (1.5 to 300 m) per cable
Matching cable Electrode cable 08712-0061-0001, same length
Sensor coil resistance (8707 High-Signal system) 12 ohms maximum
Transmitter coil drive current (8707 High-Signal system) 5 A
High-signal cable limit not recommended beyond 100 ft (30 m)
Combination alternative 08732-0753-1003

The high-signal figures come from the 8712H and 8707 section of the datasheet and apply to that system specifically; the standard 8705 and 8711 systems use their own coil drive levels.

Differences from 08712-0060-0001’s siblings

Compared with electrode cable 08712-0061-0001, 08712-0060-0001 is the heavy-gauge half of the pair and should never be substituted by the signal cable. Compared with combination cable 08732-0753-1003, which bundles a 20 AWG electrode pair with an 18 AWG coil drive in one jacket, it is thicker (14 AWG against 18 AWG), has no signal conductors, and is the correct selection for high-signal installations where the combination cable is expressly not recommended.

Where it is used

Remote 8712 transmitters mounted on a wall or panel in a control room, at a distance from the sensor on a pipeline, are the typical use. In desalination plants and water transmission lines in the Gulf, sensors are often buried or in chambers, with the transmitter in a dry kiosk; the coil drive cable runs between the two. In pulp, slurry and mining applications the 8712H/8707 high-signal system uses pulsed DC at high current, where the 14 AWG conductor matters.

Compared with a typical signal cable, a coil drive run must not exceed the voltage drop budget of the transmitter. The datasheet gives the transmitter coil drive current of 5 A and the sensor coil resistance maximum of 12 ohms for the high-signal pair, which explains why the heavier 14 AWG conductor is specified. Power consumption for that transmitter is 300 watts maximum on 120 V AC at 50 to 60 Hz, and operating ambient is minus 20 to 130 deg F (minus 29 to 54 deg C), so the transmitter must be installed in a suitable shelter in hot Gulf climates.

Installation practice

  • Order 08712-0060-0001 with the same length as the electrode cable.
  • Pull the cables in the conduit sized for both, keeping power wiring separate where the manual requires.
  • Terminate coil drive and electrode wires at the correct terminals of the transmitter and the sensor junction box.
  • Seal the sensor junction box conduit entries with IP68-approved glands if the chamber may flood.
  • Keep the cable run as short as practical: the datasheet advises that long cables degrade high-signal systems.

Where a magmeter system sits beside a motor control centre, give particular attention to separation. The coil drive carries pulsed current, and the datasheet recommends in other sections that signal wiring should not share a cable tray with AC power wiring. This is consistent with good practice for 14 AWG coil drive cable as well: keep its tray or conduit separate from power conductors where possible and cross them at right angles when they must meet.

Testing the cable

A meter check of loop resistance between the two ends and an insulation test to ground confirm integrity. If a magmeter reads a coil fault, the coil drive cable and its terminals are the first suspects. The 8714D magnetic flowmeter simulator listed in the datasheet attaches to the sensor connections of an 8712 or 8732 transmitter to verify the electronics with traceability to NIST standards.

On the standard 8732 and 8712 transmitters the basic diagnostics include coil fault and transmitter faults, and these appear on the local operator interface, over HART or in AMS. A coil fault alarm commonly means the coil drive cable is open or shorted, or a junction box terminal has loosened. Check the resistance at the transmitter end against the sensor coil resistance for the model, and compare the reading with the commissioning record. Replace damaged cable lengths in full, because a spliced coil drive cable adds resistance and a possible moisture path.

Storage and ordering

Cable is supplied by length. State the required length on the RFQ for 08712-0060-0001 and the type of installation (conduit, tray, buried). Spare drums are useful for remote pumping stations that are many kilometres from the workshop.

The lead time of cut cable is short compared with that of electronic spares, yet many plants forget to stock it. For maintenance of remote magmeters in Oman, keep one drum length per cable type in the central store, with the part numbers on the drum labels, and record every cut length so that the next requisition can confirm the remaining quantity.

Documents and quotation

The 8700 Series datasheet with the cable requirements table for 08712-0060-0001 is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send your RFQ for 08712-0060-0001 with the length, the transmitter and sensor type, and the delivery place in Oman or the GCC.

Other Models in the Rosemount 8700 Remote Cables Range

Seven Star LLC supplies models from the Rosemount 8700 Remote Cables range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 08732-0753-1003 Combination Cable 20/18 AWGAutomation AccessoriesView details
Rosemount 08712-0060-0001 Coil Drive Cable 14 AWGAutomation AccessoriesYou are viewing this model
Rosemount 08712-0061-0001 Electrode Cable 20 AWGAutomation AccessoriesView details
Datasheets & Documents
  • PDF Datasheet Rosemount 08712-0060-0001 Coil Drive Cable 14 AWG Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 08712-0060-0001 Coil Drive Cable 14 AWG

Answers from our engineering team on installation, compatibility and integration.

01What is Rosemount 08712-0060-0001?
It is the 14 AWG coil drive cable, equivalent to Belden 8720 or Alpha 2442, supplied by the foot for remote 8700 Series magnetic flowmeters.
02What is its metric part number?
08712-0060-2003 is the metric length version of the same coil drive cable.
03Can I use the electrode cable for the coil drive?
No. The coil drive is a heavier 14 AWG cable; the electrode cable 08712-0061-0001 is 20 AWG and carries the signal.
04Is the combination cable a substitute?
08732-0753-1003 combines both but is not recommended for high-signal magmeter systems and should be limited to 330 ft (100 m).
05What coil drive current does the 8712H/8707 system use?
The datasheet gives a transmitter coil drive current of 5 A and a sensor coil resistance of 12 ohms maximum for that high-signal system.