Brand:

Rosemount 02120-7000-0001 2120 Direct Load Cassette

Description

Rosemount 02120-7000-0001 direct load switching cassette: what it is

Rosemount 02120-7000-0001 is the replacement electronics cassette for the Rosemount 2120 vibrating fork level switch in its direct load switching, two-wire form. The manufacturer colour-codes it red and assigns it electronic type code T in the 2120 ordering table. It is a plug-in module, so the fork, process connection and housing stay in the tank while only the switching brain is exchanged. The datasheet states that this cassette family fits 2120 units shipped since June 2013, which is the first thing to confirm against the nameplate before an order is placed.

In practical terms the cassette lets the level switch interrupt a mains or DC load directly, without a separate relay or PLC input card. That is why it is popular for pump contactors, small solenoid valves, horns and beacons on tanks where only two conductors are available.

Electrical behaviour of the red two-wire module

  • Supply range printed in the ordering table: 20 to 264 Vac at 50 or 60 Hz, or 20 to 60 Vdc, on the same cassette.
  • Wiring uses terminals 1 to 3, with the external load (marked R in the datasheet figure) wired in series; the load must be fitted or the module will report a load-missing condition.
  • A 2 A time-lag fuse (shown as F in the wiring figure) protects the circuit, and an optional external DPST switch can serve as local disconnect.
  • Protections listed for this electronics type: polarity insensitive, over-current, short-circuit, load-missing and surge protection to IEC 61326.
  • Heartbeat LED: flashes when the output is off and stays lit when it is on, so an engineer can read the switch state without opening a meter.

Because the module is polarity insensitive, a technician cannot damage it by reversing the two supply leads, a small but real advantage during a night-time breakdown repair.

Fork and process data that still apply when 02120-7000-0001 is fitted

Parameter Value
Part number 02120-7000-0001
Electronic type code T, direct load switching (mains 2-wire)
Label colour Red
Supply 20 to 264 Vac 50/60 Hz or 20 to 60 Vdc
Switching delay (user selectable) 0.3, 1, 3, 10 or 30 s, both dry-to-wet and wet-to-dry
Switching mode Dry = on or Wet = on, user selectable
Process temperature minus 40 to 302 deg F (minus 40 to 150 deg C)
Hysteresis in water 0.1 in (2.5 mm)
Switching point in water 0.5 in (13 mm) from fork tip when vertical
Minimum liquid density 600 kg/m3 (37.5 lb/ft3)
Viscosity range up to 10000 cP
Terminal wire size 26 to 14 AWG (0.13 to 2.5 mm2)
Safety option note QS and QT safety options are not offered with electronic type T

How 02120-7000-0001 differs from other 2120 cassettes

The five other plug-in cassettes in the same family serve different control philosophies. Where 02120-7000-0001 switches mains or up to 60 Vdc straight through the fork, 02120-7000-0002 is a three-wire PNP output for 20 to 60 Vdc into a PLC input, 02120-7000-0003 is a NAMUR current signature for an intrinsically safe amplifier, 02120-7000-0004 and 02120-7000-0007 are double-pole changeover relays (the latter for a 9 to 30 Vdc supply), and 02120-7000-0005 is an 8/16 mA loop output. Only 02120-7000-0001 and the DPCO relay in 02120-7000-0004 accept the full 20 to 264 Vac mains window.

Certification freedom also differs: electronic type T can be combined with the no-approval, E-series explosion-proof and G-series ordinary-location choices, but it cannot carry the intrinsically safe I-codes, which are reserved for the NAMUR and 8/16 mA cassettes.

Where it earns its place: Gulf plant duty

Overfill and run-dry protection are the textbook uses. In an Omani fuel depot a 2120 can be set for wet-on high-level alarm duty, and the direct-load cassette can drop the contactor of a transfer pump the moment product reaches the fork, with no interposing relay. In water booster stations across the GCC the same hardware, set low-level, protects pumps from running dry. The datasheet also lists batch tanks with agitators; with the delay set to 10 or 30 seconds, splashing does not chatter the output.

Choosing this cassette: a short compatibility checklist

  • Read the existing label colour: red means the installed module is already type T and this is a like-for-like swap.
  • Check the hazardous-area marking. Intrinsically safe cassettes may only be replaced by the same type of IS cassette, so a red module is only appropriate on explosion-proof or ordinary-location 2120 units.
  • Confirm the load: the output is a switched supply to the load, not a dry contact, so the load voltage must come from the same 20 to 264 Vac or 20 to 60 Vdc source.
  • Confirm the 2120 build date is June 2013 or later, as stated by the manufacturer for these replacement cassettes.
  • If the relabelled unit will be used in safety service, remember that FMEDA and IEC 61508 options are not available with type T.

Fitting and commissioning steps

Isolate the supply and confirm the fuse rating, then remove the housing cover; leaving 1.2 in (30 mm) of clearance to turn the cover off. Withdraw the old cassette, seat 02120-7000-0001 in the same position, tighten terminals within the 26 to 14 AWG range and transfer the original part-number marking onto the new label as the manufacturer instructs. After power-up, confirm the heartbeat LED flashes with the fork dry in wet-on mode, then wet the fork and check that it turns steady. Finally hold a magnet to the side test point: the output must change state, proving the switch and the load circuit together.

Care, testing and spares planning

The fork has no moving parts or crevices that need routine service, so the cassette is the only electronic wear item. Use the magnetic test point during plant shutdowns to prove the switch end to end; the manufacturer sells a telescopic test magnet under 02100-1030-0001 for this. Keep one spare of each cassette colour used in the plant. A single red module on the shelf shortens an outage to minutes instead of waiting for factory lead time.

Documents and quotation

The datasheet for the Rosemount 2120 family, which lists 02120-7000-0001 in its spare-parts section, is attached to this page. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To obtain a quotation, send the RFQ with part number 02120-7000-0001, the quantity, the 2120 model code from the nameplate and your delivery destination in Oman or the wider GCC.

Other Models in the Rosemount 2120 Spares Range

Seven Star LLC supplies models from the Rosemount 2120 Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 02120-7000-0007 2120 Relay 9-30 Vdc CassetteLevel SwitchesView details
Rosemount 02120-7000-0001 2120 Direct Load CassetteLevel SwitchesYou are viewing this model
Rosemount 02120-7000-0005 2120 8/16 mA CassetteLevel SwitchesView details
Rosemount 02100-1060-0001 2120 Quick Release KitLevel SwitchesView details
Rosemount 02120-7000-0003 2120 NAMUR CassetteLevel SwitchesView details
Rosemount 02100-1010-0001 Adaptor Boss 1-in. BSPP Tri ClampLevel SwitchesView details
Datasheets & Documents
  • PDF Datasheet Rosemount 02120-7000-0001 2120 Direct Load Cassette Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 02120-7000-0001 2120 Direct Load Cassette

Answers from our engineering team on installation, compatibility and integration.

01What is Rosemount 02120-7000-0001 used for?
It is the replacement direct load switching (2-wire, red label) electronics cassette for the Rosemount 2120 vibrating fork level switch, electronic type code T.
02What supply voltage does Rosemount 02120-7000-0001 accept?
The ordering table states 20 to 264 Vac at 50/60 Hz or 20 to 60 Vdc, with the load wired in series and protected by a 2 A time-lag fuse.
03Can 02120-7000-0001 replace an intrinsically safe cassette?
No. The manufacturer says IS-approved cassettes may only be replaced with the same type of IS cassette; type T is for ordinary or explosion-proof builds.
04Does it protect against reversed wiring or a missing load?
Yes. The datasheet lists polarity insensitivity, over-current, short-circuit, load-missing and surge protection for the direct load electronics.
05Which 2120 units does this cassette fit?
The datasheet states the replacement cassettes are for 2120 versions shipped since June 2013, so check the build date on the nameplate first.