Brand:

ifm LMT100 Capacitive Point Level Sensor, G 1/2, IO-Link

Description

ifm LMT100 Capacitive Point Level Sensor, G 1/2, IO-Link

The ifm LMT100 is a capacitive point level sensor for tanks, vessels and pipes, preset at the factory for hydrous media. It detects liquid, viscous media and powders with a PEEK probe that is 11 mm long, and it is designed for hygienic duty with a surface roughness of Ra below 0.8 micrometres on the wetted side. Pressure rating in the tank is -1 to 40 bar, and the medium may be as hot as 100 degrees Celsius (150 degrees Celsius for up to one hour), so it survives cleaning cycles.

The housing is stainless steel with IP68 and IP69K protection. Seven Star LLC supplies the LMT100 in Oman and the GCC as an independent supplier in Muscat; quote LMT100 when you ask for an offer.

LMT100 technical specifications

The table lists the values published by the manufacturer for the LMT100. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.

Parameter Specification
Manufacturer / part number ifm electronic / LMT100
Process connection threaded connection G 1/2 sealing cone
Dimensions [mm] Ø 30 / L = 113
Probe length [mm] 11
Media liquid and viscous media; powder
Medium temperature [°C] -40 to 100
Tank pressure -1 to 40 bar / -0.1 to 4 MPa
Operating voltage [V] 18 to 30 DC
Current consumption [mA] < 50
Output signal switching signal; IO-Link
Electrical design PNP/NPN
Output function normally open / normally closed (parameterisable)
Permanent current rating of switching output DC [mA] 100
Response time [s] < 0.5
Communication interface IO-Link
Ambient temperature [°C] -40 to 85
Protection IP 68; IP 69K
Weight [g] 169.5
Materials stainless steel (316L/1.4404); PEEK; PEI; FKM
Materials (wetted parts) PEEK surface characteristics: Ra < 0.8 µm / Rz = 4 µm
Connector 1 x M12; coding: A; Contacts: 4, gold-plated
MTTF [years] 223

How the LMT100 works

The LMT100 detects the presence of a medium at the probe tip with a capacitive principle: when liquid, paste or powder reaches the probe, the capacitance of the sensing electrode changes, and the electronics compare it with a stored reference for the selected medium type. The medium type is preset at the factory and can be changed through IO-Link, which tunes the sensing to the product. Because the stainless steel body and PEEK probe have no moving parts, the sensor is not affected by wear, sticking or mechanical float problems.

Where the LMT100 fits and related parts

Among the LM point-level sensors, the LMT100 is the water-based version, while the LMT121 is preset for media with low water content and the LMC510 is preset for oils on a 1/2 inch NPT thread. All three share the capacitive principle and IO-Link, so the difference is mainly the factory medium setting and the process connection. For continuous level rather than a switch point, see the LK1022 and the LR2750.

Selection and ordering checklist for the LMT100

Work through the points below before you confirm the order, so that the LMT100 you receive is the one your machine or plant needs.

  • Confirm the medium is water-based (the factory setting is hydrous media) and note foam or build-up behaviour
  • Check tank pressure (-1 to 40 bar) and medium temperature (-40 to 100 degrees Celsius, short-time 150)
  • Match the G 1/2 sealing cone connection with the weld-in or adapter piece
  • Decide on the output mode: switching or IO-Link
  • Check the M12 cordset needed

The manufacturer lists this article under the type designation Sensor for point level detection, LMACE-A12E/QSKG/0/US. The article number LMT100 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.

Installation, commissioning and maintenance

Install the sensor in a nozzle or tank wall so that the probe tip protrudes by the stated length into the product, keeping it away from internal structures and filling jets. Seal it with the correct cone or thread seal for the process connection and observe the allowed tank pressure and medium temperature. At commissioning, select the medium type, run the tank to the switching level and check the output, and then test with product that clings to the probe to see that the build-up is rejected. Inspect the probe from time to time for heavy deposits and keep the M12 connection tight and dry.

Make sure the probe tip protrudes into the product and is not shadowed by a nozzle neck, since a long neck can hold product and give false signals. Use the correct seal for the sealing cone and tighten the connection as specified. After CIP cleaning, verify that the sensor returns to the empty state when the product drains.

Typical applications in Oman and the GCC

Food and beverage applications rely on the hygienic finish, but in Oman and the GCC the LMT100 is just as often used in water treatment, desalination dosing tanks, cooling water make-up tanks, and chemical day tanks for high and low level protection. The IP69K housing tolerates washdown and heat.

Level sensors in tanks exposed to Gulf summers must tolerate hot product, condensation on cold nozzles and long periods without attention. Plan a periodic proof test of the alarm point, and record the output state at known levels during commissioning.

LMT100 compared with related ifm types

The table places the LMT100 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.

Part number Key characteristics Note
LMT100 Capacitive, hydrous media preset, G 1/2 This page
LMT121 Capacitive, low-water media preset, G 1/2 Related type
LMC510 Capacitive, oil preset, 1/2 NPT, 2 outputs Related type
LK1022 Capacitive, 264 mm probe, 195 mm range Related type
LR2750 Guided wave radar, 150-2000 mm, G 1 Related type

Information to send with an RFQ for the LMT100

To prepare an accurate offer for the LMT100, please include the following with your enquiry:

  • Medium (water-based, oil, powder or paste) and its temperature
  • Tank pressure and cleaning method (CIP or washdown)
  • Process connection type and thread
  • Switching or IO-Link requirement
  • Quantity and delivery location

Documents and quotation

No datasheet is attached to this page. Send us the part number LMT100 and we will confirm which documents are available, such as the datasheet and operating instructions, and for IO-Link devices the device description file.

Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm LMT100 Capacitive Point Level Sensor, G 1/2,

Answers from our engineering team on installation, compatibility and integration.

01What is the factory setting of the ifm LMT100?
The LMT100 is preset for hydrous (water-based) media, and the media type can be changed through parameterisation.
02What process connection does the LMT100 have?
A G 1/2 thread with a sealing cone. This is the value published by the manufacturer for the LMT100; confirm details before ordering.
03What are the pressure and temperature limits of the LMT100?
Tank pressure is -1 to 40 bar and medium temperature is -40 to 100 degrees Celsius, with 150 degrees Celsius for up to one hour.
04What protection rating does the LMT100 have?
IP68 and IP69K. This is the value published by the manufacturer for the LMT100; confirm details before ordering.
05Can the LMT100 detect powders?
Yes, the family is specified for liquid and viscous media and for powders; the medium setting must be suitable for the product.