Brand:

Magnetrol 089-7250-001 Electronic Module with Bracket, Thermatel TD1

Description

Magnetrol 089-7250-001 overview: electronic module with bracket

The Magnetrol 089-7250-001 is the electronic module with bracket of the Thermatel TD1 thermal dispersion switch. It belongs to the Thermatel Model TD1 thermal dispersion switch, and it appears in the replacement parts section of the manufacturer instruction manual 54-610. Maintenance teams search for spare parts by this exact number because the same product family has many variants, and the wrong board, kit or displacer can leave a loop out of service.

The picture on this page shows the Thermatel Model TD1 thermal dispersion switch that the Magnetrol 089-7250-001 fits. It is the manufacturer product image for the family and not a close-up of the electronic module with bracket itself. Every value on this page comes from the manufacturer catalog and manual for that family, and where a value is not published there we have left it out instead of guessing.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list 089-7250-001 so that buyers can quote the number exactly as it appears in the manual, and we confirm availability against your quotation request.

Key features of 089-7250-001

  • Exact manufacturer part number 089-7250-001 for the electronic module with bracket.
  • Function: the electronic module with bracket of the Thermatel TD1 thermal dispersion switch.
  • Host product: Thermatel Model TD1 thermal dispersion switch, described by the manufacturer as a basic thermal dispersion flow, level and interface switch with 24 VDC power and an 8-amp DPDT relay.
  • Listed in manual 54-610, which is the reference for fitting and for the model code digits that select the part.
  • Quoted against the model number and serial number of your instrument so the variant can be checked.

Technical specifications for 089-7250-001

The first table records what the manual states about the part itself. The second table gives the main data of the host instrument from the catalog, which helps confirm that the part suits the installation. No pricing appears on this page.

Part data for 089-7250-001

Item Value
Part number 089-7250-001
Item Electronic module with bracket (item 3 in the TD1 list)
Fits Thermatel Model TD1
Related items O-ring 012-2201-237; aluminum cover 089-6607-XXX (consult factory)

Host instrument data: Thermatel TD1

Item Value
Measurement principle Thermal dispersion (heated sensor, flow or level switching)
Supply voltage (TD1) 19.2 to 28.8 VDC
Power consumption (TD1) 3.5 W at 24 VDC
Output relay (TD1) DPDT, 8 A at 120 VAC and 250 VAC, 8 A at 28.8 VDC
Ambient temperature (electronics) -40 to +70 degrees C
Sensor operating temperature -73 to +204 degrees C; high temperature sensor to +454 degrees C
Set point range (water) 0.01 to 5.0 FPS (0.003 to 1.5 m/s)
Set point range (air) 0.1 to 500 SFPS (0.03 to 150 Nm/s)
Response time 1 to 10 seconds typical
Repeatability Less than 1 percent at constant temperature

Typical applications in oil and gas, utilities, water and manufacturing

The catalog describes the TD1 and TD2 as flow, level and interface switches that detect minimum flow or the presence or absence of flow, with temperature compensation, continuous sensor diagnostics and excellent low flow sensitivity. Typical uses are flow proving on cooling or process lines and point level or interface detection. Set point ranges are listed for both water and air.

In Oman and the GCC, instruments of this kind are found in oil and gas production and processing, petrochemical and refining units, power and desalination plants, water and wastewater works, and general manufacturing. A replacement electronic module with bracket such as 089-7250-001 is normally ordered during a turnaround or after a fault, when the loop must return to service quickly, so having the exact number in hand saves time.

Selection and compatibility notes for 089-7250-001

  • The TD2 uses a different group of modules, 089-7250-002 onward, selected by supply type, so confirm the model is a TD1.
  • The probe is ordered separately by its probe model number.
  • Quote the TD1 model number and serial number.

Please treat the model code and the serial number on the nameplate as the final authority. If your instrument is older than the manual revision we reference, send the nameplate photo and we will tell you whether 089-7250-001 is listed for it before you commit to an order.

Installation and commissioning of 089-7250-001

Follow the installation section of manual 54-610 and its warnings. In particular, do not connect or disconnect energized equipment in a hazardous area unless power has been switched off or the area is known to be non-hazardous, and keep the housing covers and O-rings in good condition so the enclosure rating is kept.

  • Use a probe with heat extension or remote electronics for process temperatures above +120 degrees C, as the catalog footnote states.
  • The cable between the remote electronics and the probe can be up to 150 m (500 feet).
  • Set the switch point on the actual process media, since the set point range differs for water and air.

Maintenance and spares planning

Spare parts for process instruments are best planned from the nameplate data of each installed unit. For this family, the manufacturer lists the parts in groups, so related items are easy to review together with 089-7250-001. Keep a record of the model number, serial number and the digits that selected the part, and store electronic parts in antistatic packing until fitting. After any replacement, check the output against a known reference and record the result in the loop file.

Related products and ordering notes

Other numbers in the same manual section may suit sister variants, for example the alternatives listed in the table above. Ask us about the whole spares list for a unit if you are building a turnaround kit, and send the instrument model with every request so that 089-7250-001 is checked against it. Availability and lead time depend on stock and on the source, and we give them with the quotation.

FAQ summary for 089-7250-001

Buyers most often ask what 089-7250-001 is, which instrument it fits, whether Seven Star LLC can supply it in Oman, whether a manual is available, and what to send with a request. The answers are given in the FAQ list on this page, and in short: 089-7250-001 is the manufacturer number for the electronic module with bracket of the Thermatel TD1, and we need the model number, serial number, quantity and delivery location to quote.

Documents and quotation

The manufacturer manual 54-610 that lists 089-7250-001 is attached to this page as a PDF for reference, so you can check the part drawing and the model code table yourself. To obtain a quotation, send an RFQ with the part number 089-7250-001, the quantity, the instrument model and serial number, and the delivery location. Seven Star LLC replies with availability and lead time.

Datasheets & Documents
  • PDF Manual Magnetrol 089-7250-001 Electronic Module with Bracket, Thermatel TD1 Manual with Parts List Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol 089-7250-001 Electronic Module with

Answers from our engineering team on installation, compatibility and integration.

01What is 089-7250-001?
089-7250-001 is the Magnetrol part number for the electronic module with bracket of the Thermatel Model TD1 thermal dispersion switch. It is listed in the replacement parts section of the manufacturer manual 54-610.
02Which instrument does 089-7250-001 fit?
It is listed for the Thermatel Model TD1 thermal dispersion switch. The model code digits shown on this page select the exact variant, so please confirm the model and serial number with us before ordering.
03Can Seven Star LLC supply 089-7250-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with 089-7250-001, the quantity and the delivery location and we will confirm availability.
04Is a manual available for 089-7250-001?
Yes. The manufacturer manual 54-610 that contains the parts list for 089-7250-001 is provided as a PDF on this page, so you can check the drawing and the model code table.
05What should I send with an RFQ for 089-7250-001?
Send the part number 089-7250-001, the quantity, the instrument model number and serial number, the supply or approval details on the nameplate, and the delivery location so we can prepare an accurate quotation.