AUMA SA with LE Linear Thrust Unit: Electric Linear Actuator
Description
AUMA SA with LE linear thrust unit: electric linear actuator combination
The AUMA SA with LE combination turns an SA multi-turn actuator and an LE linear thrust unit into an electric linear actuator for globe valves and other sliding-stem valves. The thrust range is 4 kN to 217 kN, strokes run from 50 mm to 500 mm and operating speeds from 20 mm/min to 360 mm/min. If a lever arrangement has to be operated, the LE linear thrust unit can also be mounted onto a base. Seven Star LLC supplies AUMA actuators in Oman and the GCC as an independent supplier in Muscat.
SA with LE technical data
| Parameter | Specification |
|---|---|
| Manufacturer / part number | AUMA / SA with LE (combination with linear thrust unit) |
| Thrust | 4 kN to 217 kN |
| Stroke | 50 mm to 500 mm |
| Operating speed | 20 mm/min to 360 mm/min |
| Enclosure protection | IP67 |
| Corrosion protection | KS |
| Ambient temperature | -25 °C to +70 °C |
| Manual operation | Handwheel |
| Valve attachment | DIN and EN ISO standards |
| Electrical connection | AUMA plug/socket connector (terminals optional); various cable entries |
How the combination works
An SA multi-turn actuator provides a rotating output. The LE unit converts that rotation to a linear thrust through a spindle and nut, so the output moves a valve stem in a straight line. The SA actuator brings its limit and torque (thrust) sensing, handwheel and controls; the LE brings the mechanical conversion and the valve flange for globe valves. Existing site pages cover LE 12.1, LE 50.1, LE 100.1 and LE 200.1 with their individual thrust ratings of 11.5, 37.5, 128 and 217 kN.
LE sizes in the combination
| Thrust unit | Thrust |
|---|---|
| LE 12.1 | 11.5 kN |
| LE 50.1 | 37.5 kN |
| LE 100.1 | 128 kN |
| LE 200.1 | 217 kN |
The 4 kN lower end of the combination range is listed by the manufacturer for the family; the table shows the larger sizes confirmed on the existing pages.
Valve types and uses
Typical valves are globe valves, control valves with sliding stems, steam valves and valves with long stems in power and process plants. The base-mounted version operates lever-driven dampers and similar valves. Since the stroke range reaches 500 mm, the combination also suits large control valves in water systems.
Selection checklist for SA with LE
- Required thrust at closing and opening, including the seating thrust
- Stroke length within 50 to 500 mm
- Operating speed between 20 and 360 mm/min
- Valve flange and stem thread per DIN and EN ISO
- SA actuator size and controls (AM or AC), open-close or modulating
- Supply voltage, frequency and bus interface
- Ambient temperature and enclosure needs
Commissioning and maintenance
Set the end positions through the SA limit switching and verify that the stem thrust limit protects the valve at the seating. Lubricate the spindle according to the maintenance schedule and check the stem coupling for play. The handwheel provides manual operation, and because it works through the same gearing, the hand force is reduced by the LE reduction.
Applications in Oman and the GCC
Globe and control valves with sliding stems are common in power stations, boiler feed lines, steam systems and desalination plants. The listed IP67 protection and KS corrosion class are suited to outdoor installation in heat and dust, and controls with fieldbus permit integration with plant systems.
Understanding thrust, speed and stroke for SA with LE
Three quantities define an SA with LE selection: thrust, stroke and speed. The thrust requirement is the stem force needed to close the valve against the process pressure plus packing friction and seating load; the stroke is the distance from fully open to fully closed; the speed is the stem travel per minute, from which the stroke time follows. A 100 mm stroke at 100 mm/min takes one minute, which may be adequate for a feedwater valve but too slow for an emergency valve. Both limits of the manufacturer ranges, 4 to 217 kN, 50 to 500 mm and 20 to 360 mm/min, should be checked against the LE size actually proposed.
The SA actuator is sized for the input torque needed at the LE spindle, so the actuator size and the LE size must be matched by the supplier from the order data. Controls with thrust or torque switching protect the stem, and in modulating applications the SAR version with the AC controls offers positioning according to an analogue signal.
Spares and service for SA with LE
A combination has two mechanical parts and electrical controls, so spares are typically planned per part: seals and lubricant for the LE spindle, the stem nut, and the plug and socket connector for the actuator. Keep the order number and wiring diagram of the combined unit. When a replacement is required, quote the full nameplate data of both the SA and the LE.
Information to send with an RFQ
- Valve stem thrust, stroke and speed
- Valve flange details
- SA model and controls
- Supply voltage and interface
- Ambient conditions, quantity and delivery location
Site conditions in Oman for the SA with LE
Valves and their accessories in Oman work in demanding conditions: high ambient temperatures, direct sun on outdoor pipe racks, dust, and corrosive coastal air at many oil, gas and water sites. When you specify the SA with LE, confirm the pressure and temperature ratings, body and trim materials and any sour-service or hazardous-area requirements against the actual line data, and check that seals and soft parts suit the process medium and the full temperature range.
For reliable operation, plan access for maintenance, define which spare parts are kept on site, and record the configuration of each installed SA with LE. Sending the complete process data sheet with your RFQ allows the selection to be checked before the order is placed.
Documents and quotation
Send the part number SA with LE, the application and the quantity, and Seven Star LLC will confirm which official documents are available for your configuration. Please do not rely on a general description alone: the order data, wiring diagram number and explosion-protection marking of the delivered unit are what count for engineering and commissioning.
Seven Star LLC is an independent supplier in Muscat serving customers across Oman and the GCC. Quotations are prepared against your enquiry data and are confirmed individually.
Datasheets & Documents
- Datasheet AUMA SA with LE Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SA with LE Linear Thrust Unit: Electric Linear
Answers from our engineering team on installation, compatibility and integration.
01What does the SA with LE combination provide?
An electric linear actuator with thrust from 4 kN to 217 kN, stroke from 50 mm to 500 mm and speeds from 20 to 360 mm/min.
02What enclosure protection does it have?
IP67 and KS corrosion protection, with an ambient range from -25 °C to +70 °C.
03Can it operate lever valves?
Yes, the LE unit can be mounted onto a base for lever arrangements.
04Is manual operation possible?
Yes. A handwheel is fitted for manual operation.
05Which standards apply to the valve attachment?
Valve attachments are to DIN and EN ISO standards.