Brand:

AUMA SAREx 14.6 Explosion-Proof Modulating Actuator

Description

Overview

AUMA SAREx 14.6, the fifth SAREx frame, offers 250 to 500 Nm tripping torque (S4-25 %) and up to 200 / 100 Nm modulating torque (S4-25 % / S4-50 %) on the same F14 flange as the 14.2.

Seven Star LLC supplies the SAREx 14.6 as trusted AUMA supplier for Oman and the GCC and supports quotation, delivery and start-up. Larger control valves in classified areas around Sohar are typical destinations. See also the SAREx modulating Ex actuators, the SAEx range and the AUMA SDL/SDG variable-speed actuator.

Operating Principle of the AUMA SAREx 14.6

On the SAREx 14.6, the motor and gear drive a stroke that is positioned by pulses from an AMExC or ACExC positioner, with a pulse of at least 70 ms. Modulating torque is 200 / 100 Nm up to 22 rpm and falls to 120 / 60 Nm at 63 to 90 rpm. Self-locking is documented for the SAREx series.

Engineering Design of the SAREx 14.6

On the SAREx 14.6, the combination of 200 Nm modulating torque up to 22 rpm and 120 Nm at 63 to 90 rpm makes speed selection a torque decision as well as a loop-speed decision. The minimum pulse is 70 ms, and with 50 to 56 kg the actuator needs lifting equipment. A 400 mm handwheel allows manual positioning for loop checks.

Connection is by Ex plug/socket connector (KT) and spring-clamp control terminals, with IP68 sealing and a 12.5 W heater option.

Key Features of the AUMA SAREx 14.6

Headline data of the AUMA SAREx 14.6, as documented by AUMA:

  • Tripping torque of 250 to 500 Nm (S4-25 %) and 360 Nm at S4-50 %.
  • Continuous positioning torque of 200 / 100 Nm at S4-25 % / S4-50 %.
  • Output speeds of 4–90 rpm at 50 Hz, with starts graded by speed band.
  • A 400 mm handwheel; weight 50 kg (4–11 rpm), 56 kg (16–90 rpm).
  • Motor power of 0.20–3.00 kW at 400 V; pulse timing 70 ms (same direction); on reversal 280 ms at 4 rpm down to 80 ms at 90 rpm.

Selecting the AUMA SAREx 14.6 for Your Valve

The SAREx 14.6 is the heavy-duty modulating version on the F14 flange, with 250 to 500 Nm tripping torque and modulating torque up to 200 Nm (S4-25%). As the speed rises, the allowed modulating torque steps down: 200 Nm up to 22 rpm, 150 Nm at 32 and 45 rpm, and 120 Nm at 63 to 90 rpm. The starts per hour are 900, 600, 300 and 200 for the same speed bands.

The SAREx 14.6 shares its F14 flange and 58 mm stem with the 14.2 but doubles the trip ceiling to 500 Nm, with a 400 mm handwheel and 50 to 56 kg. Above 500 Nm, the SAREx 16.2 on F16 takes loops up to 1,000 Nm.

AUMA SAREx 14.6 Modulating Torque and Starts by Speed

These are the modulating limits of the AUMA SAREx 14.6 by output speed, valid at nominal voltage and +40 °C. Tripping torque is adjustable up to 500 Nm (S4-25 %) or 360 Nm (S4-50 %). Illustrative calculation, not AUMA data: a control valve with 14 turns per stroke needs 76 s at 11 rpm, 26 s at 32 rpm and 13 s at 63 rpm for a full stroke.

rpm (50 Hz) Modulating torque S4-25 / S4-50 %, Nm Max. starts per hour
4–11 200 / 100 900
16–22 200 / 100 600
32–45 150 / 75 300
63–90 120 / 60 200

Loop-tuning note: with a 70 ms minimum pulse and reversal pulses between 280 ms (4 rpm) and 80 ms (90 rpm), the SAREx 14.6 has the same pulse data as the 14.2 but works at higher torque. Modulating torque drops from 200 Nm to 120 Nm across the speed range while permitted starts fall from 900 to 200 per hour, so the slower bands combine the highest torque with the most frequent corrections.

Worked Sizing Example for the SAREx 14.6 (Illustrative Calculation)

A large anti-surge control valve shows a friction torque of 170 Nm. The SAREx 14.6 provides 200 Nm modulating torque at S4-25 % up to 22 rpm, so the 4 to 22 rpm bands are suitable, whereas 150 Nm at 32 to 45 rpm and 120 Nm at 63 to 90 rpm are not. With 900 starts per hour at 4 to 11 rpm and 600 at 16 to 22 rpm, the loop can still react quickly. This is an illustrative calculation, not AUMA data.

Motor and Electrical Data of the AUMA SAREx 14.6

4 speed points from AUMA’s separate electrical data sheet (S4-25 %, 400 V / 50 Hz), 0.20 to 3.00 kW; approximate values that are not part of the technical datasheet attached here.

Speed, rpm Motor Power, kW Nominal current, A Max. current, A Starting current, A Power factor
4 VDXR090-4-0,20 0.20 0.9 1.5 5.2 0.54
22 VDXR090-2-0,80 0.80 3.6 5.5 18 0.51
45 ADXR090-4-1,60 1.60 5.3 9.0 38 0.57
90 ADXR090-2-3,00 3.00 9.0 16 68 0.60

Explosion Protection and Installation Notes for the AUMA SAREx 14.6

Standard ATEX markings of the SAREx 14.6 per AUMA: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db. Certificate: DEKRA 11ATEX0008 X. Confirm temperature class and zone on the nameplate.

Metric cable threads are standard, with Pg, NPT or G threads as options. Corrosion protection class KS suits high salinity and near-permanent condensation.

Industrial Applications

The AUMA SAREx 14.6 is aimed at heavy control valves requiring up to 200 Nm of modulating torque, for example large throttling valves, anti-surge valves and big level-control valves on high-differential-pressure services in hazardous areas.

Gas-compression stations, large separators and pipeline control stations in Oman use this size where regulation precision and torque reserve are needed together. Seven Star LLC supplies the SAREx 14.6 with datasheet documentation and regional support.

Technical Specifications

Core data of the AUMA SAREx 14.6 as published by AUMA; the official data sheet remains binding.

Parameter Specification
Model AUMA SAREx 14.6
Torque range S4-25 % 250–500 Nm
Output speeds 4–90 rpm
Flange / stem F14 / 58 mm
Handwheel / weight 400 mm / 50 kg (4–11 rpm), 56 kg (16–90 rpm)
Gas group IIC
ATEX certificate DEKRA 11ATEX0008 X
Enclosure IP68
Modulating torque 200 / 100 Nm

Neighbouring sizes and counterparts: AUMA SAREx 14.2 explosion-proof modulating actuator, AUMA SAREx 16.2 explosion-proof modulating actuator, AUMA SAEx 14.6 explosion-proof actuator and AUMA SAR 14.6 modulating actuator.

Request a Quote for AUMA SAREx 14.6

For a quotation on the AUMA SAREx 14.6, contact Seven Star LLC with the control-valve data. The datasheet is downloadable on this page, and lead time is confirmed at quotation.

Datasheets & Documents
  • PDF Datasheet AUMA SAREx 07.2 - SAREx 16.2 Technical Data Sheet (modulating duty, 3-phase AC) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SAREx 14.6 Explosion-Proof Modulating Actuator

Answers from our engineering team on installation, compatibility and integration.

01What torque and modulating torque does the AUMA SAREx 14.6 offer?
The AUMA SAREx 14.6 has a tripping torque range of 250 to 500 Nm at S4-25 % duty and up to 360 Nm at S4-50 %. The maximum modulating torque is 200 / 100 Nm (S4-25 % / S4-50 %), and on some frames it is reduced at higher output speeds.
02Which flange, stem size and handwheel does the AUMA SAREx 14.6 use?
The AUMA SAREx 14.6 uses an EN ISO 5210 F14 flange (DIN 3210 option G1/2), accepts rising stems up to 58 mm and has a 400 mm handwheel as stated in the data sheet. Approximate weight is 50 kg (4–11 rpm), 56 kg (16–90 rpm).
03What explosion protection does the AUMA SAREx 14.6 carry?
AUMA documents these standard ATEX markings for the AUMA SAREx 14.6: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db, with certificate DEKRA 11ATEX0008 X. This covers gas group IIC; confirm temperature class T4 or T3 and the zone on the supplied nameplate and certificate.
04How often can the AUMA SAREx 14.6 start and what pulse times apply?
The data sheet gives the maximum starts per hour by speed band (4–11 rpm: 900; 16–22 rpm: 600; 32–45 rpm: 300; 63–90 rpm: 200) and the pulse timing as: 70 ms (same direction); on reversal 280 ms at 4 rpm down to 80 ms at 90 rpm. An AMExC or ACExC control is needed to drive the actuator.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so the AUMA SAREx 14.6 is supplied as genuine AUMA product with documentation and regional technical support.