Brand:

AUMA SAR 07.6 Modulating Multi-Turn Actuator

Description

Overview

AUMA SAR 07.6 is an AUMA NORM multi-turn actuator for modulating duty (class C, ISO 22153) with a tripping-torque window of 30 to 60 Nm and 10 output speeds from 4 to 90 rpm. SAR 07.6 gives AUMA’s compact modulating actuator frame 30 to 60 Nm of tripping torque and 30 Nm of modulating torque at S4-25 percent, twice that of the SAR 07.2 while keeping the same F07 and F10 flange and 160 mm handwheel.

Seven Star LLC supplies AUMA products across Oman and the GCC, and supplies the SAR 07.6 with local technical support from Muscat.

Operating Principle

On the SAR 07.6, the positioner sends short pulses and the actuator holds each position by self-locking. S4 – 25 percent duty, class C, allows 30 Nm modulating torque at 4 to 45 rpm, easing to 20 Nm at 63 to 90 rpm, with a 50 ms minimum pulse.

Engineering Design of the AUMA SAR 07.6

AUMA lists up to 1,500 starts per hour, a minimum pulse of 50 ms and a reversal pulse of 60 to 260 ms depending on speed. The optional S5-25 percent duty requires insulation class H. Always pair the actuator with AUMA MATIC AM or AUMATIC AC controls, since the AUMA NORM version requires external electric controls.

Key Features

Points to weigh when specifying the AUMA SAR 07.6:

  • Modulating multi-turn actuator, doubled torque in the compact housing.
  • Choose any trip value between 30 and 60 Nm; the span from smallest to largest setting is 2.0 to 1.
  • Switching to S4 – 50 percent duty reduces the ceiling to 40 Nm (67 percent of the maximum).
  • Each kilogram of actuator mass corresponds to about 2.9 to 3.0 Nm of maximum torque.
  • An illustrative stroke of 18 turns takes about 49.1 seconds at 22 rpm.
  • Torque class: between the SAR 07.2 (below) and the SAR 10.2 (above).
  • For dimensions and wiring data, refer to AUMA’s dedicated sheets for this size.

Selecting the AUMA SAR 07.6

The AUMA SAR 07.6 is distinguished from the SAR 07.2 by torque only: the weight is quoted at 20 to 21 kg instead of 19 to 20 kg and the interfaces are identical. Its modulating torque steps down from 30 Nm to 20 Nm at 63 and 90 rpm in S4-25 percent duty, and from 20 Nm to 15 Nm in S4-50 percent duty, so fast positioning on a stiff valve reduces the torque available. For most control valves a medium speed of 8 to 22 rpm is the best compromise between response time and torque margin.

Typical partners are small and medium globe control valves, modulating gate valves, rising-stem control valves for steam conditioning and attemperation, and flow-control valves in chemical dosing and mixing lines.

On a small control valve the friction of the packing is a large part of the total running torque. When a PTFE chevron packing is replaced with graphite on a steam valve, the running torque can rise and so can the stick-slip effect that causes a modulating actuator to overshoot. The AUMA SAR 07.6 has 30 Nm of modulating torque at S4-25 percent, so there is room to accept a stiffer packing than the 15 Nm of the SAR 07.2 would allow. Compare the running torque of the valve at 25 percent, 50 percent and 75 percent of stroke, because modulating duty is determined by the worst of these points.

Sizing example for the AUMA SAR 07.6

Take an illustrative control valve that needs 25 Nm running torque and 48 Nm at the seat. The running torque is within the 30 Nm modulating limit for S4-25 percent up to 45 rpm, and the seat torque falls inside the 30 to 60 Nm window. At 63 or 90 rpm the modulating limit falls to 20 Nm (S4-25 percent), so the valve would be outside the permitted range, which makes 22 rpm a better selection. A 15-turn stroke at 22 rpm takes about 41 seconds. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SAR 07.6

The 20 to 21 kg AUMA SAR 07.6 fits the same F07 and F10 valve interfaces as the SAR 07.2, so existing yokes and adapters can be reused. Mount it so that cable glands point down, protect the 160 mm handwheel from being used as a step, and make sure the position transmitter, potentiometer or 0/4 – 20 mA, is specified with the order since it cannot easily be added when the controls are fitted later.

Industrial Applications

Typical Omani applications are condensate and feed-water control on package boilers, cooling-water temperature control valves for compressors and gas turbines, and mixing valves in district-cooling energy centres. Plant engineers in the Sohar and Salalah industrial zones also use the AUMA SAR 07.6 as a replacement for ageing modulating actuators when the valve flange is F07 or F10.

Projects often pair the SAR 07.6 with the AUMA SAR 14.1 multi-turn actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAREx explosion-proof modulating actuator, all available from Seven Star LLC as trusted AUMA supplier.

Neighbouring sizes and counterparts: AUMA SAR 07.2 modulating actuator, AUMA SAR 10.2 modulating actuator, AUMA SA 07.6 multi-turn actuator and AUMA SAREx 07.6 explosion-proof modulating actuator.

Technical Specifications

Data of the AUMA SAR 07.6 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SAR 07.6
Torque window, S4 – 25 percent 30 to 60 Nm
Ceiling, S4 – 50 percent 40 Nm
Torque while modulating 30 Nm (S4-25%) and 20 Nm (S4-50%) up to 45 rpm, reducing to 20 Nm and 15 Nm at 63 and 90 rpm
Permitted starts per hour 1,500 per hour (1,200 per hour at 63 and 90 rpm)
Shortest pulse 50 ms
Reversal delay (maximum) 260 ms at 4 rpm down to 60 ms at 90 rpm
Speed range 4 to 90 rpm at 50 Hz, 4.8 to 108 rpm at 60 Hz, 10 steps
Flange EN ISO 5210 F07 and F10; DIN 3210 G0 (option; not offered with F07)
Stem capacity 26 mm (34 mm with the F10 flange; 30 mm maximum with the PMMA stem protection tube)
Handwheel size 160 mm
Mass 20 to 21 kg
Protection class IP68
Holds position Yes

Setpoint guide for the SAR 07.6 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
24 30
28 35
32 40
36 45
42 53
48 60

Stroking time for 18 turns at the SAR 07.6 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 18 turns at 50 Hz
4 4.8 270
5.6 6.7 193
8 9.6 135
11 13 98
16 19 68
22 26 49
32 38 34
45 54 24
63 75 17
90 108 12

Ordering details for SAR 07.6

The SAR 07.6 technical data lists the valve mounting arrangement as F07 / F10 (ISO 5210), DIN 3210 G0. Identify the modulating duty, starts per hour and output speed at the installation frequency on the enquiry.

Technical reference

Request a Quote for AUMA SAR 07.6

Contact Seven Star LLC to buy the AUMA SAR 07.6 in the 30 to 60 Nm class. Share valve and positioner data, and download the AUMA datasheet from this page.

Datasheets & Documents
  • PDF Datasheet AUMA SAR 07.2 - SAR 16.2 Technical Data Sheet (covers AUMA SAR 07.6) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SAR 07.6 Modulating Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SAR 07.6?
The tripping torque of the AUMA SAR 07.6 is adjustable between 30 and 60 Nm at S4 - 25 percent and up to 40 Nm at S4 - 50 percent.
02What modulating performance does the AUMA SAR 07.6 offer?
The AUMA SAR 07.6 is rated for S4 - 25 percent modulating duty, class C, with a modulating torque of 30 Nm (S4-25%) and 20 Nm (S4-50%) up to 45 rpm, reducing to 20 Nm and 15 Nm at 63 and 90 rpm. It allows 1,500 per hour (1,200 per hour at 63 and 90 rpm), with a minimum pulse of 50 ms and a reversal delay of 260 ms at 4 rpm down to 60 ms at 90 rpm.
03Which valve flange and stem size does the AUMA SAR 07.6 fit?
The AUMA SAR 07.6 fits an EN ISO 5210 F07 or F10 flange, accepts a rising stem up to 26 mm (34 mm on F10) and offers DIN 3210 G0 as an option. It has a 160 mm handwheel and weighs 20 to 21 kg.
04When should I choose the AUMA SAR 07.6 instead of a neighbouring size?
Use the AUMA SAR 07.6 when the maximum valve torque lies between about 30 and 60 Nm and the running torque while modulating does not exceed 30 Nm (S4-25 percent). Lighter valves can use the SAR 07.2, and stiffer valves move to the SAR 10.2 with 60 to 120 Nm.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SAR 07.6 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.