Endress+Hauser Promass 80F Coriolis Mass Flowmeter

Description

Overview

The Endress+Hauser Promass 80F measures mass flow, density and temperature of liquids and gases. The 80 transmitter can be mounted on the sensor or installed remotely where access or process temperature makes a compact installation impractical.

Measurement Principle

The Endress+Hauser Promass 80F operates on the Coriolis measuring principle. Process fluid is directed through a pair of curved measuring tubes driven into oscillation at their natural resonant frequency; as mass flows through the vibrating tubes, the Coriolis force creates a measurable phase shift between the tube legs that is directly proportional to mass flow rate, while the resonant frequency itself shifts in proportion to fluid density.

The 80F requires no upstream or downstream straight pipe run. The measuring tubes still cause pressure loss. Endress+Hauser specifies using its Applicator sizing tool to check that loss at the intended flow rate (technical information TI00101D, page 28).

Engineering Design of the Endress+Hauser Promass 80F

The F sensor covers DN 8 to DN 250. Tube and manifold materials depend on diameter and the ordered version. The process-connection pressure rating and the secondary-containment rating are separate specifications. Check both against the order code and the pressure–temperature limits for the flange material.

The transmitter is available in compact (sensor-mounted) or remote configurations, with a 2-line backlit local display and push-button interface for on-site diagnostics and configuration, fully compliant with IEC/EN/NAMUR standards. This flexibility allows the Promass 80F to be installed where vibration, heat, or access constraints make a sensor-mounted transmitter impractical.

Key Features

The Endress+Hauser Promass 80F is built for demanding process duty where accuracy has to hold under stress, and the Endress+Hauser Promass 80F remains a proven workhorse across upstream and downstream applications:

  • Delivers mass flow accuracy of ±0.15% standard, improving to ±0.1% with the calibration option.
  • Process-connection ratings depend on flange standard and material. Secondary containment is rated up to 40 bar on applicable versions.
  • Measures mass flow, density, temperature, volume flow, corrected volume flow, and reference density from one device.
  • Covers a measuring range from 0 to 2,200,000 kg/h across its DN 8 to DN 250 nominal diameter range.
  • Handles medium temperatures from –50°C to +350°C in the high-temperature variant.
  • Available with compact or remote transmitter mounting to suit site access and vibration constraints.
  • Requires no inlet or outlet straight-run piping, saving space on tightly packed skids.
  • Offered in corrosion-resistant wetted materials including 904L stainless steel and Alloy C22 for aggressive media.

Industrial Applications

The 80F is used for liquid and gas mass-flow measurement in chemical and process plants. Identify the fluid, its density at operating conditions and the normal and maximum flow rates when sizing a new measuring point.

With engineering support in Muscat, Seven Star LLC supplies the Promass 80F to process industries throughout Oman and the GCC, including projects in the Sohar and Salalah economic zones, refining and petrochemical complexes, and district cooling and desalination plants, with technical support and lead time confirmed at quotation.

Technical Specifications

Key technical parameters for the Endress+Hauser Promass 80F are summarized below.

Parameter Specification
Model Endress+Hauser Proline Promass 80F
Measuring Principle Coriolis
Nominal Diameter DN 8 to DN 250 (3/8″ to 10″)
Mass Flow Accuracy (Liquid) ±0.15% standard, ±0.1% option
Mass Flow Accuracy (Gas) ±0.35%
Liquid density accuracy under reference conditions ±0.0005 g/cm³
Process-connection ratings Up to PN 100, Class 600 or 63K according to the selected flange
Medium Temperature –50°C to +200°C standard, up to +350°C high-temperature variant
Wetted Materials 1.4539 (904L), 1.4404 (316/316L), Alloy C22 (2.4602 / UNS N06022)
Measured Variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density

Why Choose Seven Star LLC for Endress+Hauser Coriolis Flowmeters

For an existing measuring point, provide the extended order code, serial number and calibration requirements. These identify the measuring tube, transmitter and process connection for the quotation.

Selecting the temperature version of the 80F

The Promass 80F has a high-temperature version rated up to 350 °C. Check the installed sensor version and process connection before specifying that limit. Provide the nominal diameter, process pressure and the minimum and maximum fluid temperatures for a replacement.

Manufacturer’s technical reference

Request a Quote for Endress+Hauser Promass 80F Coriolis Mass Flowmeter

Send the process data and required documentation to Seven Star LLC for a Promass 80F quotation in Oman or the GCC. Specify any calibration certificate or regulatory approval required for the installation.

Related Products

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Promass 80F and 83F Technical Information (TI00101D) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Promass 80F Coriolis Mass Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01What makes the Endress+Hauser Promass 80F suited to demanding process conditions?
The Promass 80F uses a pressure-rated sensor housing certified to PN 100 / Class 600 / 63K, up to 40 bar, and covers medium temperatures from -50C to +350C in its high-temperature variant, allowing it to hold accuracy through the pressure and temperature swings typical of refinery and petrochemical duty.
02Does the Promass 80F require straight pipe runs for installation?
No. Like all Coriolis meters, the Promass 80F measures mass directly rather than relying on a developed flow profile, so no inlet or outlet straight-run piping is required, which saves installation space on retrofit and revamp projects.
03What line sizes and materials are available for the Promass 80F?
The Promass 80F covers DN 8 to DN 250 (3/8 inch to 10 inch) with wetted parts in 1.4539 (904L), 1.4404 (316/316L), or Alloy C22, and dedicated high-temperature variants are available at DN 25, DN 50, and DN 80.
04Can the Promass 80F replace an older or legacy flow instrument on the same line?
Yes. The transmitter is available in compact or remote mounting and is fully IEC/EN/NAMUR compliant, so it integrates into existing 4-20mA/HART loops and control system architectures without requiring a full instrumentation overhaul.
05Is Seven Star LLC an experienced supply partner for Endress+Hauser products?
Yes. Seven Star LLC supplies Endress+Hauser (E & H) products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.