Endress+Hauser CM72 Liquiline Compact Single-Parameter Transmitter

Description

Endress+Hauser CM72 Liquiline Compact single-parameter transmitter

The Endress+Hauser CM72 is a space-saving two-wire transmitter for Memosens sensors, configured at the factory for one parameter. It handles pH, ORP, contacting conductivity or oxygen sensors with the blue plug-in head and outputs a 4 to 20 mA signal straight to a PLC.

This makes the CM72 a low-cost solution for plants and skid builders that want a ready-to-run measuring point with no commissioning, in line with the datasheet’s note that it can start measuring immediately.

What the CM72 offers

  • Permanent configuration, no commissioning needed
  • Two-wire, loop-powered, fits into an assembly
  • Red/green LED for transmitter and sensor status
  • Selectable measuring range matched to the sensor type
  • Hot plug-and-play with lab-calibrated Memosens sensors
  • Rugged PEEK housing, IP 67/IP 68, NEMA Type 6

CM72 technical table

Parameter Value
Output 4 to 20 mA, galvanically isolated, linear
Supply voltage 12.6 to 30 V DC or 14 to 30 V DC depending on failure current
Sensor types pH, ORP, conductivity, oxygen Memosens
pH range 0 to 14
ORP range Minus 1500 to plus 1500 mV
Conductivity ranges 0 to 20 or 500 microsiemens per cm; 0 to 20 or 500 mS per cm
Oxygen ranges 0 to 200 micrograms per litre; 0 to 20 mg/l
Cable length 3, 7 or 15 m
Protection IP 67, IP 68, NEMA Type 6
Weight About 42 g without cable
Storage temperature Minus 40 to 85 °C

How CM72 differs from CM82

Compared with the CM82, the CM72 has no HART and no Bluetooth interface in its datasheet, cannot be reconfigured and does not accept combined pH/ORP sensors. In exchange, it needs no commissioning and costs less to specify. The two share the same housing material, cable lengths, loop supply and 42 g body.

Applications in the Gulf

Typical uses include dosing-pump interlocks, small RO skids, cooling-water pH monitoring and aeration-basin oxygen sensing, where a PLC analog input is all that is needed. The CM72 suits OEM skids built for the Gulf market that must be commissioned quickly.

Installation

Plug the CM72 onto its Memosens sensor, check the loop supply is within the stated range, and connect to the PLC. Confirm that the 4 and 20 mA points correspond to the ordered range.

Maintenance

If the LED shows a fault, check the sensor and cable first. Calibrate sensors in the lab, and swap the sensor with the CM72 attached or replace the transmitter separately.

Permanent configuration and what it means at the order stage

The CM72 is configured once, at the factory, for a specific sensor type and measuring range, and the datasheet states that the choice cannot be changed later. The available ranges are pH 0 to 14, ORP minus 1500 to plus 1500 mV, conductivity 0 to 20 microsiemens per cm, 0 to 500 microsiemens per cm, 0 to 20 mS per cm or 0 to 500 mS per cm, and oxygen 0 to 200 micrograms per litre or 0 to 20 mg per litre. The option for a turndown of the current output is likewise selected at the order stage. Because there is nothing to set up, a CM72 starts measuring immediately once the sensor is plugged in, and a red/green LED shows the state of the transmitter and the connected sensor.

The price of that simplicity is flexibility: if the sensor or range changes, a different CM72 is required. For plants that expect to change sensor types, the CM82 with its software configuration is the safer choice.

Electrical and mechanical facts

Output is 4 to 20 mA, galvanically isolated from the sensor circuits, linear in both linearization and transmission behavior. The supply is 12.6 to 30 V DC when the failure current is above 20 mA, and 14 to 30 V DC when it is below 4 mA. Cable lengths are 3 m, 7 m or 15 m. Ambient temperature is minus 20 to 85 degrees Celsius, with the process-temperature relationship stated in the datasheet, storage minus 40 to 85 degrees Celsius, and relative humidity 5 to 95 percent. Protection is IP 67 and IP 68 with NEMA Type 6, and the pollution degree is 4 for the complete device. The body is about 124.6 mm long, 18.95 mm in diameter at the narrowest section, and weighs about 42 g plus roughly 48 g per metre of cable.

Memosens benefits in a loop-powered device

The Memosens sensor stores calibration data, so a CM72 can follow a sensor calibrated in the lab. Records such as total operating hours, hours at extreme values, hours at high temperature, number of steam sterilizations and sensor condition support predictive maintenance. Non-contact digital transmission gives good galvanic isolation, avoids contact corrosion and keeps the connection watertight.

Spare strategy and ordering notes for the CM72

Because each CM72 is configured for one sensor type and range, spares must match the installed configuration exactly. Keep a list of the installed units with the sensor type and range printed on the nameplate, then stock one spare for each configuration, rather than a generic spare. Where a site mixes pH, ORP, conductivity and oxygen points, this can become a short list, but it is worth maintaining.

Always mention the cable length (3, 7 or 15 m), the sensor family and the range when requesting a quote. For plants that would rather keep one universal spare, the CM82 offers that flexibility at the cost of a software configuration step. The CM72, with its LED and no menu, is best suited to simple, repeatable measuring points.

Electrical environment

The CM72 is tested to EN 61326-1 and EN 61326-2-3 for electromagnetic compatibility and follows NAMUR NE 21, with electrical safety to EN 61010-1 and operation up to 2000 m above sea level. These points matter when the transmitter is installed near variable-frequency drives and pumps in water plants, where electrical noise can disturb analog signals.

Documents and quotation

The datasheet for the CM72 is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with CM72, the sensor type and range code, cable length and quantity.

Other Models in the Liquiline Compact Range

Seven Star LLC supplies models from the Liquiline Compact range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CM82 Liquiline Compact TransmitterLiquid Analytical SystemsView details
Endress+Hauser CM72 Liquiline Compact Single-Parameter TransmitterLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CM72 Liquiline Compact Single-Parameter Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CM72 Liquiline Compact

Answers from our engineering team on installation, compatibility and integration.

01Can I change the range of the CM72 after delivery?
No, the datasheet says the configuration is chosen at order and cannot be changed later.
02Which parameters can the CM72 measure?
pH, ORP, contacting conductivity and dissolved oxygen, depending on the ordered configuration.
03How does the CM72 show its status?
A red/green LED indicates the state of the transmitter and the connected sensor.
04What output does the CM72 give?
A linear 4 to 20 mA signal, galvanically isolated from the sensor circuits, powered over the same two wires.
05What cable lengths are available for the CM72?
The cable is offered in 3, 7 or 15 m lengths, with about 48 g added per extra metre.