Endress+Hauser PMD75-1QA7H11DADU Deltabar Differential Pressure Transmitter 0-3 bar
Overview
The Endress+Hauser PMD75 Deltabar is a digital differential pressure transmitter built on the proven Cerabar/Deltabar S sensor platform, and this configuration, order code PMD75-1QA7H11DADU, is factory-calibrated to a 0-3 bar differential range. This mid-range span makes the Endress+Hauser PMD75 the workhorse setting for orifice-plate flow measurement, pump discharge/suction differential monitoring, and vessel differential interlocks where the pressure swing is larger than a filter-monitoring application but still requires tight, repeatable accuracy across the full span.
Working closely with plant engineers in the region, Seven Star LLC proudly supplies the PMD75 Deltabar to refineries, utility operators, and industrial manufacturers across the Sultanate of Oman, Muscat, and the wider GCC region. Specifying the PMD75 through Seven Star LLC comes with a formal quotation, the manufacturer datasheet and technical support with selection.
Measurement Principle
The PMD75 measures differential pressure by applying the high-side and low-side process pressures across opposite faces of an internal diaphragm, which deflects in proportion to the pressure difference between the two ports. This deflection changes the capacitance of an internal measuring cell, and the transmitter’s digital electronics convert that capacitance change into a precise electrical signal representing the differential pressure, independent of absolute line pressure fluctuations, an important property in the 0-3 bar range where static line pressure can be significantly higher than the measured differential.
Because the PMD75 measures the differential directly at the sensor rather than deriving it from two separate absolute measurements, it eliminates the subtraction error that would otherwise erode accuracy at the top and bottom of the calibrated span, delivering reference accuracy of up to 0.075% of the calibrated span across the full 0-3 bar range. This direct-measurement approach also gives the PMD75 excellent long-term stability and a fast response time, both essential when the transmitter drives the square-root extraction used in orifice-plate flow computation.
Engineering Design of the Endress+Hauser PMD75
The PMD75 uses a two-chamber transmitter housing, available in aluminum or stainless steel, that physically separates the terminal compartment from the electronics compartment so that field wiring can be serviced without exposure to the measuring circuitry. The process wetted parts and diaphragm seal materials are selected at the point of order to match the process medium, and the instrument supports both direct process connection via a five-way or three-way manifold and remote-seal configurations depending on the installation.
A backlit local display with a four-key operating concept allows field engineers to configure the zero and span, apply damping, and read diagnostic information without a separate handheld communicator, while the HART-based 4-20mA output integrates directly with existing control loops. The PMD75 is designed to IEC 61508 and can be applied in SIL2/SIL3 safety instrumented functions, an important consideration for differential pressure loops tied to pump protection and vessel-level interlocks.
Key Features
The Endress+Hauser PMD75 combines mid-range differential accuracy with rugged industrial construction. Core capabilities include:
- Factory-calibrated 0-3 bar differential pressure range suited to orifice-plate flow and pump differential duties.
- Reference accuracy of up to 0.075% of calibrated span maintained across the full measuring range.
- Direct differential measurement that avoids the subtraction error inherent in dual absolute-pressure setups.
- Two-chamber aluminum or stainless steel housing isolating wiring from sensitive electronics.
- Local backlit display with four-key configuration for on-site zero, span, and damping adjustment.
- SIL2/SIL3-capable design per IEC 61508 for use in pump protection and vessel interlock systems.
- HART-compatible 4-20mA output for seamless integration with existing DCS and PLC platforms.
- Compatible with three-way and five-way manifolds for straightforward impulse line installation.
Industrial Applications
The 0-3 bar span of this Endress+Hauser PMD75 configuration is widely specified for orifice-plate and venturi flow measurement on process water, cooling water, and utility air systems throughout Oman’s industrial and desalination facilities, where the differential signal is extracted to a square-root flow output for custody transfer and process control. Pump manufacturers and skid builders across the GCC also rely on this mid-range Endress+Hauser PMD75 for continuous pump discharge-to-suction differential monitoring, protecting rotating equipment from cavitation and dry-run conditions.
With fast quotation turnaround and technical support, Seven Star LLC distributes the Deltabar PMD75 to EPC contractors and plant operators throughout the Sohar and Salalah economic zones, supporting vessel differential-level interlocks, dP-based flow totalization, and pump protection schemes. Facility engineers across the region rely on Seven Star LLC for both the initial specification of the correct calibrated range and the long-term parts and calibration support that follows commissioning.
Technical Specifications
Full technical parameters for the Endress+Hauser PMD75 differential pressure transmitter, order code PMD75-1QA7H11DADU, are summarized below to help engineers confirm the Endress+Hauser PMD75 matches their process requirements before submitting a purchase order:
| Parameter | Specification |
|---|---|
| Model | Endress+Hauser PMD75 Deltabar |
| Order Code | PMD75-1QA7H11DADU |
| Measuring Principle | Capacitive Differential Pressure |
| Calibrated Range | 0 to 3 bar |
| Accuracy | Up to 0.075% of calibrated span |
| Output Signal | 4-20mA / HART |
| Housing | Two-chamber, aluminum or stainless steel |
| Safety Rating | SIL2/SIL3 capable per IEC 61508 |
| Display | Local backlit display, 4-key operation |
Request a Quote for Endress+Hauser PMD75-1QA7H11DADU Deltabar Differential Pressure Transmitter 0-3 bar
To submit a formal Request for Quote (RFQ), confirm current availability and lead time, or obtain the complete technical datasheet for the Endress+Hauser PMD75-1QA7H11DADU Deltabar differential pressure transmitter, please contact the instrumentation division at Seven Star LLC today. With engineering support in Muscat, our engineers are ready to support specification and sourcing for your differential pressure measurement project.
Related Products
- Honeywell SmartLine STG700 Gauge Pressure Transmitter
- Endress+Hauser PMP71-1QA1W11RDADU Cerabar Pressure Transmitter 0-400 bar
- JUMO dTRANS p30 Pressure Transmitter
- ABB-Hygienic Absolute pressure transmitter PAF100
- Endress+Hauser 5P5B80-BDEBADAAFBLL2BEA Flange-Mount Pressure Transmitter
- Yokogawa EJA110E Differential Pressure Transmitter (DPharp Sensor)
- Instruction Manual Endress+Hauser PMD75-1QA7H11DADU Deltabar Differential Pressure Transmitter 0-3 bar Manual Download

Reviews
There are no reviews yet.