- Automation & ControlView all 2,610 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser CA80PH Liquiline System Orthophosphate Analyzer
Description
CA80PH Liquiline System orthophosphate analyzer from Endress+Hauser
The Endress+Hauser CA80PH is a colorimetric wet-chemical analyzer for the almost continuous determination of orthophosphate in liquid media, with blue-method and yellow-method versions and up to two measuring channels. It is a member of the Liquiline System CA80 family: a cabinet analyzer with an integrated controller, a graphic display and optional digital Memosens sensor inputs. Seven Star LLC, an independent supplier in Muscat, supplies the CA80PH in Oman and the GCC, and this page explains what the analyzer measures, how it is configured and what to confirm before ordering.
Typical uses named in the manufacturer documentation: Monitoring and optimization of the treatment efficiency of municipal and industrial wastewater treatment plants, monitoring and optimization of aeration basins, regulation of precipitant dosage and monitoring of cooling water circuits.
CA80PH technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / CA80PH |
| Measured variable | PO4, PO4-P, P2O5 [mg/l, ppm] |
| Measuring range | CA80PH-**E1: 0 to 2.5 mg/l PO4-P (blue); -**E2: 0.05 to 10 mg/l (blue); -**E3: 0.5 to 20 mg/l (yellow); -**E4: 0.5 to 50 mg/l (yellow) |
| Dilution option | E2 with dilution factor 50 reaches 2.5 to 500 mg/l; E4 with factor 20 reaches 10 to 1,000 mg/l |
| Maximum measured error | 2 % of end of measuring range; dilution factor 5 adds 2.0 % (blue) or 3.0 % (yellow) |
| Limit of detection | 0.015 mg/l PO4-P (blue method only) |
| Repeatability | Blue: ±2 % of display value + 0.01 mg/l; yellow: ±2 % of display value + 0.05 mg/l |
| Measuring interval | Blue: continuous (approx. 11 min), adjustable above 11 min; yellow: approx. 8 min, adjustable above 10 min |
| Sample requirement | 22 ml per measurement without dilution module |
| Reagent requirement | Blue: approx. 50 µl per reagent per measurement; yellow: approx. 115 µl per measurement |
| Standard requirement | About 230 ml a month at a 48 h calibration interval |
| Maintenance | Every 3 to 6 months, about 1 hour a quarter; cleaning interval 1 h to 90 days |
| Sample | 4 to 40 °C, turbidity below 50 NTU, aqueous, homogenized |
| Power consumption | 130 VA plus 660 VA per hose heater, max. 1450 VA with cooling system; 24 V version max. 105 W |
| Ambient temperature | +5 to +40 °C; outdoor version −20 to +40 °C |
| Weight | Cabinet 42 kg with cooling module or 39.5 kg without; open version 34 or 31.5 kg; stand 75 or 72.5 kg |
How the CA80PH measures
Phosphorus occurs in natural water and wastewater mainly as phosphate. It enters from leached fertilizer, from biological and industrial waste and from substances dosed for corrosion protection. The CA80PH determines the orthophosphate fraction by a colorimetric reaction: a color reagent is metered into the cuvette, the sample changes color, and a multispectral photometer reads the absorption at defined wavelengths to give a concentration.
Two reaction chemistries are available. The blue method serves low concentrations (codes E1 and E2), and the yellow method serves higher concentrations (codes E3 and E4). A reference measurement is subtracted before each result and the photometer temperature is held constant. The analyzer can optionally be ordered with a reagent cooling module, which the documentation lists as extending reagent life.
Controller, inputs, outputs and communication of the CA80PH
The analyzer is more than a single-parameter box. The controller supports one measuring channel for the analyzer itself plus, optionally, one to four digital Memosens sensor inputs (cable length up to 100 m), two passive 0/4 to 20 mA inputs and binary inputs. Outputs are two active 0/4 to 20 mA outputs as standard (four or six with additional modules), an alarm relay and optional extension relays. Fieldbus and network options are PROFIBUS DP, Modbus RS485, Modbus TCP, EtherNet/IP and PROFINET, and a web server gives browser access to configuration, measured values, diagnostics and logbooks. Alarm current follows NAMUR NE 43 with a factory failure current of 21.5 mA.
Data handling is thorough: ring or stack logbooks for analog values, events, calibration, hardware, versions, operations and diagnostics, with an SD card for software updates, configuration backup and logbook export. Up to six virtual process values can be calculated from the measured values and sent to an output or fieldbus. Configuration is possible from the front display, FieldCare, Field Data Manager software and the web server.
Where the CA80PH sits in the CA80 family
The CA80PH measures orthophosphate only; if total phosphorus is required, the CA80TP is the family member for that parameter. The CA80TN covers total nitrogen and the CA80COD covers COD, so a wastewater plant can build a nutrient and load monitoring set from one controller family.
The CA80PH is the family member where the choice of chemistry matters most: the blue method serves trace levels, the yellow method serves tens of mg/l.
Selection and ordering checklist for the CA80PH
- Concentration band to choose among E1, E2, E3 and E4, and therefore blue or yellow chemistry.
- Whether the dilution module and its demineralized water supply is needed for very high phosphate.
- Reagent cooling module for longer reagent life in warm shelters.
- One or two measuring channels and the number of sampling points.
- Sample filtration upstream if turbidity can exceed 50 NTU.
- Supply voltage, hose heating, outdoor version, outputs and fieldbus.
Installation, commissioning and maintenance of the CA80PH
The housing can be mounted on a wall, on a base (indoors only) or on a post accessory. The documentation asks you to protect the analyzer from additional heating, mechanical vibration and corrosive gases such as hydrogen sulfide, to keep it where air can circulate at the front, and to make sure the waste line drains freely without siphoning. Pay attention to the maximum height difference and distance to the sampling point, and keep the sample line short. Open versions without a door belong only in a closed room or protective cabinet.
After commissioning, calibration interval, cleaning and reagent exchange are set on the display. Reagents are replaced every few months and standard solution use is about 230 ml a month at a 48-hour calibration interval, with weekly visual checks and about an hour of maintenance a quarter. The reagent cooling module, if fitted, should be included in your spare-parts plan. Counters monitor reagent, hoses and dispensers, and a leak sensor inside the housing and photometer temperature monitoring raise diagnostic messages, so keep spare hoses and reagent sets on site before they run out.
Typical CA80PH applications in Oman and the GCC
In the GCC the CA80PH is relevant to municipal sewage treatment works, tertiary treatment of reuse water, industrial effluent from food and chemical plants, and cooling-water circuits where phosphate-based inhibitors are dosed. Warm shelters make the optional reagent cooling module worth considering, and the cabinet upper ambient limit of +40 °C should be respected.
Information to send with your CA80PH RFQ
- The full order code or the exact range and options needed (measuring range, dilution, cabinet or outdoor, hose heater, fieldbus).
- Sample description: temperature, solids, expected concentration and distance from the sampling point.
- Power supply (100 to 120 V AC, 200 to 240 V AC or 24 V DC where offered) and area ambient range.
- Required outputs, relays and fieldbus, plus any Memosens sensors to be connected.
- Reagent, standard and spare-part needs for the first year of operation.
Documents and quotation
The Endress+Hauser Technical Information for the CA80PH is attached on this page as a datasheet. Send the part number and your sample and site details, and we will confirm configuration, reagent supply, lead time and availability for Oman and the GCC.
Other Models in the Eh Liquiline Ca80 Range
Seven Star LLC supplies models from the Eh Liquiline Ca80 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CA80COD Liquiline System COD Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80PH Liquiline System Orthophosphate Analyzer | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser CA80PH Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CA80PH Liquiline System
Answers from our engineering team on installation, compatibility and integration.
01What does the CA80PH measure?
It measures orthophosphate, reported as PO4-P, PO4 or P2O5, using a colorimetric method with either the blue or the yellow chemistry.
02Which ranges does the CA80PH offer?
Code E1 is 0 to 2.5 mg/l and E2 is 0.05 to 10 mg/l (blue method), while E3 is 0.5 to 20 mg/l and E4 is 0.5 to 50 mg/l (yellow method).
03Can the CA80PH have a cooled reagent compartment?
Yes. A reagent cooling module is optional and is listed by the manufacturer to extend reagent lifetime.
04How often does the CA80PH measure?
The blue method cycles about every 11 minutes and the yellow method about every 8 minutes, and longer intervals can be configured.
05Can the CA80PH help control precipitant dosing?
The manufacturer lists regulation of precipitant dosage as an application, using the analyzer value through current outputs, relays or a fieldbus.


















Reviews
There are no reviews yet.