Endress+Hauser CA80SI Liquiline Silica Analyzer for Boiler Water

Description

CA80SI is the silica analyzer for power-plant water chemistry

Silica carries over with steam and deposits on turbine blades, so boiler and steam cycle operators track it in micrograms per litre. Endress+Hauser CA80SI uses the heteropoly blue method: silicate forms yellow silicomolybdic acid with molybdate, citric acid destroys the phosphate interference and an amino acid reduces the complex to intense blue, which a multispectral photometer reads. The datasheet lists ultrapure water, boiler feedwater, steam and condensate analysis and reverse osmosis as applications.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Technical information TI01315C, edition 07.25-00, supplies the figures.

CA80SI specification

Parameter Value
Variable SiO2 in mg/l, ug/l, ppm or ppb
Ranges AH: 0 to 500 ug/l; AJ: 0 to 5000 ug/l
Channels 1, 2, 4 or 6, up to 4 Memosens inputs optional
Repeatability 0.5 ug/l or plus or minus 1 percent below 500 ug/l; 1 percent from 500 ug/l
Interval About 10 min; adjustable above 10 min; factory 20 min
Sample requirement Over 140 ml per measurement, flow dependent
Sample supply 2 to 6 bar abs, recommended 2.5 to 4 bar; 60 to 250 ml/min, recommended 70 ml/min; 5 to 45 degrees C
Reagent use 200 ul per reagent per measurement; 1000 ml set about 65 days at 20 min; 2500 ml about 100 days at 12 min
Standard About 140 ml per calibration
Supply 100 to 120 / 200 to 240 V AC, 50 or 60 Hz; typical 60 VA, maximum 1250 VA
Ambient 5 to 40 degrees C; humidity 10 to 95 percent
Protection IP55, Type 3R
Weight Cabinet 40 kg; open installation 32 kg; analyzer stand 73 kg

Interference and pH limits

Sodium chloride up to 2000 mg/l, hardness up to 25 degrees dH as CaCl2, and phosphate up to 10 mg/l (measurement error below 4 ug/l) are tolerated, and the sample pH range 4 to 12 is stated for the 0 to 500 ug/l measurement. Phosphate is the classical interferent, which is why the chemistry includes citric acid.

How CA80SI differs from the other CA80 analyzers

CA80SI is the only analyzer in this group that is supplied for a pressurised sample of 2 to 6 bar and with a flow rate window, because power-plant sample lines arrive from conditioned sampling panels. It lists only the 100 to 120 and 200 to 240 V AC supply and a 5 to 40 degrees C ambient range, with no 24 V DC or outdoor variant, and it comes with up to six measuring channels where AL, FE and HA offer one or two. Its ranges, 0 to 500 or 0 to 5000 ug/l, are the lowest and the repeatability of 0.5 ug/l is far tighter than the mg/l-level analyzers.

Installing CA80SI at a power plant

  • Connect a conditioned sample at 2.5 to 4 bar and about 70 ml/min.
  • Keep the sample temperature between 5 and 45 degrees C using a cooler if necessary.
  • Plan 140 ml sample per measurement and the lower reagent interval to match plant chemistry.
  • Use a standard bottle of 2.5 l; at a calibration interval of 96 hours it lasts about 65 days.
  • Add Memosens sensors such as conductivity or pH to the same controller, up to four.

Reagents, standards and operation of CA80SI

Reagent use is 200 ul per reagent per measurement at intervals of 15 minutes or longer. One 1000 ml set lasts about 65 days at a 20 minute interval, while a 2500 ml set lasts about 100 days at 12 minutes, so the supply plan can be built around a quarterly change. A calibration consumes about 140 ml of standard, and a 2.5 litre standard bottle used at a 96 hour calibration interval lasts about 65 days. Typical power draw is about 60 VA for a 230 V device with 80 ml/min sample at 25 degrees C, rising to a maximum of 1250 VA during heating. With a fieldbus connection the supply voltage may not apply, as the datasheet notes.

Fieldbus options include PROFINET, PROFIBUS DP, Modbus TCP, Modbus RS485 and EtherNet/IP with a web server, and tool-free maintenance keeps the reagent changeover quick for plant technicians.

Use in Gulf power and desalination plants

Combined cycle and steam plants in Oman, and thermal desalination with boilers, require low silica in feedwater. A CA80SI at the RO permeate and demineraliser outlet gives early warning of resin exhaustion, and at the steam drum it supports blowdown optimisation.

CA80SI questions answered briefly

What is Endress+Hauser CA80SI designed to measure? Silica as SiO2 in ultrapure water, boiler feedwater, steam and condensate and reverse osmosis permeate, by the heteropoly blue method.

What ranges does CA80SI offer? AH versions measure 0 to 500 ug/l and AJ versions 0 to 5000 ug/l SiO2.

How many channels can CA80SI have? 1, 2, 4 or 6 measuring channels depending on the order version, plus up to 4 optional Memosens sensor inputs.

What sample supply does CA80SI need? Pressurised 2 to 6 bar absolute (2.5 to 4 bar recommended), flow 60 to 250 ml/min (70 recommended), at 5 to 45 degrees C.

How long do the CA80SI reagents last? One 1000 ml set lasts about 65 days at a 20 minute interval and a 2500 ml set about 100 days at a 12 minute interval.

Documents and quotation

The datasheet for CA80SI is attached to this page for checking every range, sample requirement and consumption figure before ordering. Please send an RFQ with CA80SI, the range (AH or AJ), number of channels and quantity, and tell us the sample pressure, flow and temperature available from your sample conditioning panel, together with the reagent set size you prefer.

Delivery to Sites in Oman and the GCC

Delivery of the Endress+Hauser CA80SI is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive liquid analytical systems equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Other Models in the Liquiline Ca80 Range

Seven Star LLC supplies models from the Liquiline Ca80 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CA80FE Liquiline Dissolved Iron AnalyzerLiquid Analytical SystemsView details
Endress+Hauser CA80SI Liquiline Silica Analyzer for Boiler WaterLiquid Analytical SystemsYou are viewing this model
Endress+Hauser CA80HA Liquiline Water Hardness AnalyzerLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CA80SI Liquiline Silica Analyzer for Boiler Water Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CA80SI Liquiline Silica Analyzer for

Answers from our engineering team on installation, compatibility and integration.

01What is Endress+Hauser CA80SI designed to measure?
Silica as SiO2 in ultrapure water, boiler feedwater, steam and condensate and reverse osmosis permeate, by the heteropoly blue method.
02What ranges does CA80SI offer?
AH versions measure 0 to 500 ug/l and AJ versions 0 to 5000 ug/l SiO2.
03How many channels can CA80SI have?
1, 2, 4 or 6 measuring channels depending on the order version, plus up to 4 optional Memosens sensor inputs.
04What sample supply does CA80SI need?
Pressurised 2 to 6 bar absolute (2.5 to 4 bar recommended), flow 60 to 250 ml/min (70 recommended), at 5 to 45 degrees C.
05How long do the CA80SI reagents last?
One 1000 ml set lasts about 65 days at a 20 minute interval and a 2500 ml set about 100 days at a 12 minute interval.