SADP-P SHAW Automatic DewPoint Meter
Overview
The Shaw SADP-P Automatic DewPoint Meter is a portable hygrometer for fast, reliable measurement of trace moisture in process gases and dry compressed air. It is designed for applications where very low dew point measurement is required, with an analogue range covering -100 to 0 C dew point and 0 to 6000 ppm(v) water content.
Based on the world-renowned Shaw moisture measurement technology, the SADP-P is easy to use in the field, with a single on/off switch, an AutoCal potentiometer for quick calibration, and a large, easy-to-read LCD indicator showing readings in C or F dew point.
Engineering & Design
The instrument is designed to operate at atmospheric pressure and provides direct dew point readout, making it suitable for spot-checking dryers, instrument air systems, and process gas streams. The AutoCal potentiometer allows the user to calibrate the instrument against a known reference, maintaining measurement confidence without laboratory support.
Trace moisture measurement at these levels is critical in power generation, semiconductor manufacture, and pharmaceutical applications, where the presence of water vapour can degrade products, processes, or equipment.
Key Features
- Portable automatic dew point measurement
- Analogue range -100 to 0 C DP
- Water content range 0 to 6000 ppm(v)
- Large, easy-to-read LCD indicator
- Readings in C or F dew point
- Single on/off switch operation
- AutoCal potentiometer for field calibration
- Operates at atmospheric pressure
- Proven Shaw moisture measurement technology
Applications
- Dry compressed air quality spot checks
- Instrument air system verification
- Process gas trace moisture measurement
- Power generation applications
- Semiconductor manufacture
- Pharmaceutical process verification
Specifications
| Specification | Value |
|---|---|
| Manufacturer | Shaw Moisture Meters |
| Model | SADP-P |
| Type | Portable automatic dewpoint meter |
| Analogue Range | -100 to 0 C DP |
| Water Content Range | 0 to 6000 ppm(v) |
| Display | Large LCD indicator |
| Units | C or F dew point |
| Calibration | AutoCal potentiometer |
| Operating Pressure | Atmospheric |
Trace moisture measurement protects processes and products, and the Shaw SADP-P Automatic DewPoint Meter is a proven instrument for that duty, which is why Seven Star LLC supplies the Shaw SADP-P dewpoint meter for compressed air and process gas applications.
The Shaw SADP-P automatic dewpoint meter is the portable dew point meter of the Shaw series, and the Shaw SADP-P automatic dewpoint meter provides the automatic measurement of the gas moisture for the site verification.
The SADP-P meter is supplied with the carrying case and the sample hose kit, and the instrument is powered from the rechargeable battery for the field use. The reading is automatically corrected for the temperature and the pressure of the sample, and the dew point is displayed in the selected engineering unit. The monthly verification against the reference instrument keeps the field readings traceable for the quality records of the compressed air system.
The SADP-P is also used for the verification of the desiccant dryers and the membrane dryers, where the outlet dew point is compared against the specification of the drying plant. The instrument is carried on the maintenance rounds of the instrument air network and the records are kept for the plant quality review.
Why Seven Star LLC
Seven Star LLC supplies the Shaw SADP-P Automatic DewPoint Meter for moisture measurement applications across the Gulf, with full documentation and calibration support. Our team assists with instrument selection for your dew point range and application requirements.
We support compressed air quality, process gas, and power generation customers with reliable B2B supply and responsive technical service.
Field Performance
The SADP-P’s wide -100 to 0 C DP analogue range and 0 to 6000 ppm(v) water content indication cover the dryness levels required in instrument air and process gas systems. The single-switch operation and AutoCal potentiometer make it practical for technicians in the field.
The large LCD displays the reading in C or F dew point, giving an immediate result without complex setup, and the instrument’s atmospheric-pressure design suits the spot-checking role for which it is most commonly used.
Request a Quote for SADP-P SHAW Automatic DewPoint Meter
For the Shaw SADP-P dewpoint meter, automatic dew point meter or any related control and instrumentation requirement, contact the Seven Star LLC team. Submit a formal inquiry through our RFQ page with your measurement range, connection and configuration, and our specialists will respond with a detailed commercial proposal and the Shaw product documentation.
Taking a Reliable Spot Measurement
Trace moisture readings depend heavily on sampling technique. Use short, clean, dry sample tubing, preferably stainless steel or PTFE rather than rubber or nylon hose, which can release or absorb moisture. Purge the sample line and connections thoroughly before taking a reading, and allow the indication to settle, since very dry gases take longer to reach equilibrium. Because the meter measures at atmospheric pressure, the sample must be let down to atmospheric pressure in a controlled way, and any conversion to line-pressure dew point should use a recognised conversion method.
Routine Checks and Calibration
- Check the instrument against a known reference, using the AutoCal facility, at an interval that suits the site quality system
- Keep the sensor and sampling accessories capped and dry when not in use
- Record each reading with the date, sample point and conditions so that trends can be compared over time
- Return the instrument for sensor service or recalibration if readings cannot be brought into agreement with the reference
Troubleshooting Common Issues
A reading that falls very slowly is usually caused by moisture held in the sample line or fittings, not by a fault in the meter; longer purging or drier tubing normally solves it. Readings wetter than expected at a dryer outlet may indicate a genuine dryer problem, such as saturated desiccant or a failed regeneration cycle, and should be confirmed with a second measurement before action is taken. Oil contamination can affect the sensor, so a suitable filter is advisable when sampling compressed air downstream of oil-lubricated compressors.
Use in Oman and the GCC
High ambient temperature and humidity in coastal areas of the region put a heavy load on air dryers, which makes regular dew point checks of instrument air and nitrogen systems particularly valuable at refineries, power plants and gas processing sites.
Supply from Seven Star LLC
Seven Star LLC can supply the Shaw SADP-P automatic dewpoint meter and associated sampling accessories. Tell us the gases to be measured and the expected dew point range, and our team will confirm suitability before quotation.
Related Products
- Instruction Manual SHAW Instruments SADP-P SHAW Automatic DewPoint Meter Manual Download
SHAW dewpoint meters and how they are used
The SADP is a portable hygrometer for spot checks. A small sample flow passes over the sensor in the instrument head, which is kept dry between tests, and the reading is taken at the sample point. Typical checks are instrument air after a dryer, nitrogen and other industrial gases, natural gas, and welding or cryogenic gases. SHAW also makes the hand-held SDHmini and the intrinsically safe SDHmini-Ex, the fixed Superdew 3 hygrometer and the AcuDew and SDT-Ex dewpoint transmitters for continuous measurement.Ordering a SHAW dewpoint meter: what we need
A SHAW meter is defined by its sensor range. State the driest and wettest dewpoint you expect, the gas, the line pressure at the sample point and the display units wanted (°C or °F dewpoint, ppm). For a replacement or a spare sensor, send the model and serial number from the instrument label. We supply to the GCC and provide the manufacturer's documents on request.Browse SHAW Instruments products by category: Gas Analyzer Systems.