Endress+Hauser Prowirl 72F Vortex Flowmeter

Description

Overview

The Endress+Hauser Prowirl 72F is a robust and safe vortex flowmeter designed for the universal measurement of gases, steam, and liquids, suitable for safety-instrumented applications up to SIL 2. Its patented capacitive DSC sensor delivers high-precision measured values even under the toughest process conditions, including high temperature steam service and pulsating flow.

With fast quotation turnaround and technical support, Seven Star LLC proudly supplies the Endress+Hauser Prowirl 72F to power plants, process industries, and utilities across the Sultanate of Oman and the wider GCC, backed by genuine factory calibration, full documentation, and local technical support.

Measurement Principle

The Endress+Hauser Prowirl 72F operates on the vortex shedding principle. A bluff body positioned in the flow path generates alternating vortices as fluid passes, at a frequency directly proportional to flow velocity; the patented capacitive DSC sensor detects these vortices and converts the signal into an accurate volumetric flow measurement independent of fluid density or pressure changes at a given velocity.

Because vortex shedding is a well-understood, repeatable physical phenomenon, the Prowirl 72F delivers consistent accuracy across gases, steam, and liquids from a single sensor design. The instrument has no moving parts to wear in the measuring path itself, and its high-temperature rating makes it a proven choice for steam metering where mechanical meters degrade quickly.

Engineering Design of the Endress+Hauser Prowirl 72F

The sensor is available in nominal diameters from DN 15 to DN 300 (1/2 inch to 12 inch), rated for process pressures from PN 10 to PN 250 (Class 150 to 1500, JIS 10K to 40K) and medium temperatures from –200°C to +400°C, with up to +450°C available on request for specialized high-temperature steam applications.

The transmitter features a two-line liquid crystal display with push-button operation and quick setup capability, housed to IP67 (NEMA 4X) protection. The compact version operates in ambient temperatures from –40°C to +70°C, while the remote sensor version extends to +85°C, giving flexibility for installation near hot process lines.

Key Features

The Endress+Hauser Prowirl 72F is engineered for universal, high-precision flow measurement, and the Endress+Hauser Prowirl 72F is proven across steam, gas, and liquid duty in demanding industrial plants:

  • Measures gases, steam, and liquids from a single vortex sensor design with a patented capacitive DSC sensor.
  • Delivers measurement accuracy better than 0.75% of reading for liquids and 1% for gas and steam.
  • Handles medium temperatures from –200°C to +400°C with the high/low temperature sensor (standard sensor –40°C to +260°C), with up to +450°C available on request.
  • Is rated for process pressures up to PN 250 (Class 1500, JIS 40K) for high-pressure steam and gas lines.
  • Is suitable for safety-instrumented systems up to SIL 2.
  • Covers nominal diameters from DN 15 to DN 300 (1/2 inch to 12 inch).
  • Achieves IP67 (NEMA 4X) protection with a two-line backlit display for on-site readouts.
  • Offers compact or remote transmitter mounting to suit hot or vibration-prone installation points.

Industrial Applications

The Endress+Hauser Prowirl 72F is specified for steam metering in power plants and process utilities, saturated and superheated steam custody transfer, natural gas and compressed air measurement, and general liquid flow duty where a single robust instrument must cover multiple fluid types. Its wide temperature and pressure ratings also suit refinery and petrochemical steam and gas networks.

With engineering support in Muscat, Seven Star LLC supplies the Prowirl 72F to power generation and process facilities throughout Oman and the GCC, including projects in the Sohar and Salalah economic zones, district cooling plants, and refining and petrochemical complexes, with technical support and lead time confirmed at quotation.

Technical Specifications

Key technical parameters for the Endress+Hauser Prowirl 72F are summarized below.

Parameter Specification
Model Endress+Hauser Proline Prowirl 72F
Measuring Principle Vortex shedding (capacitive DSC sensor)
Nominal Diameter DN 15 to DN 300 (1/2″ to 12″)
Measurement Accuracy Liquids: better than 0.75% of reading; gas and steam: better than 1% of reading (Reynolds number above 20,000)
Medium Temperature -40 °C to +260 °C with standard sensor; -200 °C to +400 °C with high/low temperature sensor (up to +450 °C on request)
Max Process Pressure PN 10–250, Class 150–1500, JIS 10–40K
Safety Rating Suitable for SIL 2 applications
Degree of Protection IP67 (NEMA 4X)
Product status (endress.com) No longer available; successors listed: Proline Prowirl F 200, Prowirl O 200, Prowirl R 200
Repeatability ±0.25 % of reading
Full scale velocity (liquids) 9 m/s
Outputs 4-20 mA HART; pulse/status output (passive, galvanically isolated); vortex frequency 0.5 to 2850 Hz; PFM; PROFIBUS PA; FOUNDATION Fieldbus H1
Supply voltage HART Non-Ex 12 to 36 V DC (18 to 36 V with HART); Ex i/Ex n 12 to 30 V; Ex d 15 to 36 V
Supply voltage fieldbus PA/FF: non-Ex 9 to 32 V DC; Ex i/Ex n 9 to 24 V; Ex d 9 to 32 V; 16 mA
Seal temperature limits Graphite -200 to +400 °C; Viton -15 to +175 °C; Kalrez -20 to +275 °C; Gylon (PTFE) -200 to +260 °C
Materials Meter body A351-CF3M (1.4408) or Alloy C-22; PN 250 / Cl. 900-1500: 316Ti (1.4571); DSC sensor wetted 316L, Inconel 718 or titanium Gr. 5
Ambient temperature Compact -40 to +70 °C (Ex d -40 to +60 °C); remote sensor -40 to +85 °C; remote transmitter -40 to +80 °C
Ex approvals ATEX II 1/2G EEx ia IIC, II 2G EEx d [ia] IIC, II 3G EEx nA; FM and CSA Class I/II/III Div. 1; TIIS; NEPSI
Design options R Style / S Style integrated diameter reduction by one or two line sizes; Dualsens version with two sensors and electronics

Prowirl 72F Accuracy by Fluid, Sensor Versions and Outputs

Endress+Hauser specifies the Prowirl 72 separately for liquids and for gas or steam. In liquids the maximum measured error is below 0.75 % of reading at Reynolds numbers above 20000; for gas and steam it is below 1 % of reading under the same condition and at velocities below 75 m/s. Between Reynolds 4000 and 20000 the same percentages apply to the full scale value instead of the reading. Repeatability is ±0.25 % of reading, and the full scale velocity for liquids is 9 m/s.

The fluid temperature range depends on the DSC sensor and seal selected. The standard capacitive DSC sensor covers -40 to +260 °C; the high/low temperature sensor extends this to -200 to +400 °C. High pressure versions use an Inconel 718 sensor (PN 63 to 160, Class 600) or a titanium Grade 5 sensor (PN 250, Class 900 to 1500), the latter from -50 °C. Graphite seals cover the full range, while Viton is limited to -15 to +175 °C and Kalrez to -20 to +275 °C.

The transmitter is loop powered: 12 to 36 V DC in non-Ex service, 12 to 30 V as Ex i and 15 to 36 V as Ex d, with 18 V or 21 V minimum when HART communication is used. In addition to 4-20 mA HART, a passive pulse/status output can deliver scaled pulses, limit values, the raw vortex frequency (0.5 to 2850 Hz) or a PFM signal for an RMC621 or RMS621 flow computer. PROFIBUS PA and FOUNDATION Fieldbus versions draw 16 mA.

Prowirl 72F Product Status, Successors and Inlet Run Requirements

The Prowirl 72F belongs to the earlier Proline generation. On endress.com the manufacturer states that the product is no longer available and directs users to the new generation: Proline Prowirl F 200, Prowirl O 200 for high pressure and Prowirl R 200 with line size reduction. For plants running installed 72F meters, the functional safety statement in the Technical Information remains relevant: Prowirl 72 is rated SIL 2 to IEC 61508 / IEC 61511-1.

Vortex meters need a fully developed flow profile. The minimum inlet runs given by Endress+Hauser are 15 × DN after a reduction, 17 × DN plus 8 times the step height after an expansion, 20 × DN after a 90 degree elbow or T-piece, 25 × DN after two elbows in one plane, 40 × DN after two elbows in different planes and 50 × DN after a control valve, each with 5 × DN downstream. A perforated plate flow conditioner is offered where these lengths cannot be provided.

Why Choose Seven Star LLC for Endress+Hauser Vortex Flowmeters

A vortex meter rated for SIL 2 safety-instrumented duty has to be specified with the correct pressure class and temperature rating for genuinely demanding steam or high-pressure gas service, and a mismatch on a safety loop is a far more serious problem than on a simple indication point. Seven Star LLC works with your process safety and instrumentation engineers to confirm the Prowirl 72F’s pressure, temperature, and SIL configuration against your actual safety-instrumented system requirements, backed by our trusted Endress+Hauser suppliership across Oman and the wider GCC. We also support power generation and petrochemical facilities in Sohar and Salalah with coordinated documentation for safety-loop commissioning and with planning compact-versus-remote transmitter mounting around hot steam lines.

Request a Quote for Endress+Hauser Prowirl 72F Vortex Flowmeter

For steam, gas, and liquid metering points standardizing on the Endress+Hauser Prowirl 72F, Seven Star LLC is ready to support your project with a formal RFQ, technical datasheet, and delivery timeline. Our instrumentation engineers provide technical support with selection across Oman and the GCC, with lead time confirmed at quotation. Backed by manufacturer datasheet documentation, contact our instrumentation division today to configure the right Prowirl 72F variant for your process, complete with genuine calibration certificates and full documentation.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Endress+Hauser Prowirl 72F Vortex Flowmeter Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Prowirl 72F Vortex Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01Can the Endress+Hauser Prowirl 72F measure steam, gas, and liquid with the same sensor?
Yes. The vortex shedding principle used by the Prowirl 72F applies equally to gases, steam, and liquids, and the patented capacitive DSC sensor maintains accurate detection across all three fluid types from a single instrument design.
02Is the Prowirl 72F suitable for high-temperature steam service?
Yes. The Prowirl 72F is rated for medium temperatures from -200C to +400C with the high/low temperature sensor (standard sensor -40C to +260C), and is rated up to PN 250 / Class 1500 / JIS 40K, making it well suited to saturated and superheated steam applications.
03Is the Prowirl 72F suitable for safety-instrumented systems?
Yes. The Prowirl 72F is suitable for safety-instrumented applications up to SIL 2, making it appropriate for critical steam and process safety loops.
04What line sizes does the Prowirl 72F support?
The Prowirl 72F covers DN 15 to DN 300 (1/2 inch to 12 inch), with process pressure ratings from PN 10 to PN 250 depending on line size and flange standard.
05Is Seven Star LLC an experienced supply partner for Endress+Hauser products?
Yes. Seven Star LLC supplies Endress+Hauser (E & H) products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.