Honeywell STR87G SmartLine Remote Seal Gauge Transmitter, 3000 psi
Description
High-pressure remote seal gauge transmitter: Honeywell STR87G
At the top of the STR800 range, the STR87G measures gauge pressure up to 3000 psi (210 bar) from a lower limit of minus 14.7 psi (minus 1.0 bar). The minimum span is 30 psi (2.1 bar), the reference turndown for its accuracy equation is 10:1, and the maximum turndown is 100:1. It is built on the STG87L high-pressure sensor, and a single capillary links it to the diaphragm seal on the process connection.
The seal keeps abrasive, corrosive or hot media out of the sensor. The oil-filled capillary then carries the pressure signal up to the electronics, which can be mounted away from vibration, heat or the confined space of a skid. Where the process medium is a polymerising liquid, a hydrogen-bearing gas or a clean-in-place line, a remote seal is often the only workable approach at 3000 psi.
Characteristics of STR87G
| Parameter | Value |
|---|---|
| Model | STR87G, remote-seal gauge, high pressure |
| Range | -14.7 to 3,000 psi (-1.0 to 210 bar) |
| Minimum span | 30 psi (2.1 bar) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.0375 percent of span |
| Reference turndown | 10:1 |
| Base transmitter | STG87L (stability 0.01 percent of URL per year) |
| MAWP | 3,000 psig (210 bar) |
| No-burst rule | 2.5 times MAWP plus 1,000 psi, because MAWP is above 2,000 psi |
| Fill fluid, meter body | Silicone 200, CTFE, Silicone 704 or NEOBEE M-20 |
| Fill fluid, seal system | Silicone 200, CTFE, Silicone 704, Syltherm 800 or NEOBEE M-20 |
| Capillary | 5 to 35 ft (1.5 to 10.7 m), armoured stainless steel |
| Seal gasket | Viton, graphite or Teflon |
| Output | 4 to 20 mA with HART 7 or DE, or FOUNDATION Fieldbus |
Choosing STR87G instead of STR84G
The difference between the STR87G and the STR84G is range and span. A 500 psi STR84G can be calibrated down to 5 psi, whereas the STR87G needs at least 30 psi. For a line that only reaches 400 psi in normal operation, the STR84G will give a better resolution; for a hydraulic, injection or high-pressure test line, the STR87G is the only option in the STR800 family that covers up to 3000 psi. Both have the same 0.0375 percent reference accuracy and use a single high-side capillary.
Because the capillary is only on the high side and Honeywell does not compensate for oil expansion, the datasheet gives no combined temperature effect for the STR87G. Use the base STG87L figures as a rough guide, and apply the minimum span table for the seal diameter: for example a 2.4 inch seal with 35 ft of capillary needs 50 psi, and a 4.1 inch seal at the same length needs 8 psi, but since the base minimum is 30 psi the higher figure of 30 psi applies in the second case.
Applications for the STR87G
- Gas-injection and water-injection headers at oilfield sites.
- Hydraulic power units and test rigs in maintenance workshops and manufacturing.
- High-pressure reactor feeds in chemical plants.
- High-pressure steam and condensate lines where a sealed system protects the sensor from heat.
- Pigging and pipeline test stations where mounting the transmitter at ground level is safer than at the pipe.
Mounting notes for the STR87G at 3000 psi
At 3000 psi a leak is a safety hazard, so the connection between process and seal flange should follow the plant piping class and gasket recommendations. Honeywell lists Viton, graphite and PTFE seal gaskets; use graphite for high temperature and Viton or PTFE for chemical compatibility. Torque flange bolts evenly. Only the STR87G body should be supported by the bracket, not the capillary, and the electronics housing should be turned to face the operator using the 0, 90, 180 or 270 degree display positions.
Diagnostics and lifecycle of the STR87G
The ST 800 family monitors itself and reports critical and non-critical diagnostics through HART or Fieldbus using NAMUR NE-107 categories. Calibration verification should be planned like for any pressure transmitter, but remember that a damaged seal diaphragm normally means replacing the matched seal assembly as a unit.
Electrical, protocol and display options available with STR87G
The transmitter head is a standard SmartLine ST 800 electronics assembly. On HART it works from 10.8 to 42.4 VDC at the terminals with a load up to 1,440 ohms; Honeywell DE needs 15 to 49.3 VDC with up to 1,200 ohms; FOUNDATION Fieldbus runs on 9.0 to 32.0 VDC at a steady 17.6 mA. Intrinsically safe versions are limited to 30 VDC. Output failure modes follow either the Honeywell standard (normal 3.8 to 20.8 mA) or NAMUR NE 43 (3.8 to 20.5 mA), and in both cases failure drives the output to 3.6 mA or below, or 21.0 mA or above.
Damping on HART is adjustable from 0 to 32 seconds in 0.1 second steps, which is useful on pulsating injection pumps that send a 3000 psi pressure ripple through the capillary. An optional lightning-protection block rated 5000 A at 8/20 microseconds helps on exposed wellhead and pipeline sites.
Verification and frequent errors with STR87G
Three mistakes recur on remote-seal gauge units. The first is calibrating a STR87G at the workshop bench with the capillary coiled and the seal at a different height from the field installation, which leaves a head offset. The second is choosing a span near the 30 psi minimum with a small seal and long capillary, which magnifies temperature error. The third is exceeding the seal flange rating when the pipe class is higher than the seal flange class; the working pressure is the lower of the body rating and the seal rating, as the datasheet states. Check all three before commissioning.
Ordering the STR87G
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For the STR87G please supply the seal type and diaphragm material, flange rating, capillary length, fill fluid, protocol, housing and approvals.
Documents and quotation
Honeywell specification 34-ST-03-88 is attached as the datasheet for the STR87G. Send your RFQ with the part number STR87G, quantity and delivery location in Oman or the GCC, and we will reply with availability and lead time.
Other Models in the Honeywell Str800 Range
Seven Star LLC supplies models from the Honeywell Str800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STR84G SmartLine Remote Seal Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STR82D SmartLine Remote Seal Differential Transmitter | Pressure Transmitters | View details |
| Honeywell STR87G SmartLine Remote Seal Gauge Transmitter, 3000 psi | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell STR87G SmartLine Remote Seal Gauge Transmitter, 3000 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STR87G SmartLine Remote Seal Gauge
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure range of the Honeywell STR87G?
Minus 14.7 psi up to 3,000 psi (minus 1.0 to 210 bar), with a minimum span of 30 psi (2.1 bar) and turndown up to 100:1.
02What is the MAWP of the STR87G?
3,000 psig (210 bar), with overpressure at 1.5 times MAWP and a no-burst pressure of 2.5 times MAWP plus 1,000 psi.
03Which base transmitter does the STR87G use?
The STG87L in-line gauge transmitter, which Honeywell specifies with 0.01 percent of URL per year stability for the base unit.
04Is the STR87G suitable for vacuum?
Its lower range limit is minus 14.7 psi (minus 1.0 bar), so it can measure vacuum, though the 30 psi minimum span limits resolution at small values.
05How long can the STR87G capillary be?
Capillary lengths of 5, 10, 15, 20, 25 and 35 feet (1.5 to 10.7 m) are listed; the maximum for a given seal depends on diaphragm size.