Brand:

Honeywell STF828 SmartLine Flange-Mounted Level Transmitter

Description

Honeywell STF828 flange-mounted level transmitter overview

The Honeywell STF828 measures liquid level in open or pressurised tanks by bolting straight onto a tank flange. It belongs to the SmartLine STF800 family and covers the low-pressure range of plus and minus 400 inH2O (plus and minus 1000 mbar), with a minimum span of 4 inH2O (10 mbar). The STF828 offers flush or extended diaphragm configurations, so a single transmitter body can serve clean liquids, viscous products, slurries and tanks with crusting or polymerising media that would plug an impulse line.

Compared with a conventional differential-pressure level setup, a flange-mounted instrument removes the wet leg, the impulse tubing and two manifold valves. The STF828 therefore removes common leak points and the maintenance involved in keeping a reference leg filled. The datasheet lists a standard accuracy of 0.0375 percent of span (0.025 percent optional), stability of 0.01 percent of URL per year over 15 years, and rangeability up to 100:1.

STF828 specification table

Parameter Value
Model STF828, flange-mounted level, low range
Upper / lower range limit 400 inH2O / -400 inH2O (1000 mbar / -1000 mbar)
Minimum span 4 inH2O (10 mbar)
Maximum turndown 100:1
Reference accuracy, percent of span 0.0375 standard, 0.025 optional
Stability 0.01 percent of URL per year, 15 years
Reference turndown for accuracy 16:1
Total performance example 0.436 percent of span at 80 inH2O
Flange sizes 2, 3 or 4 inch ANSI Class 150 or 300; DN50, DN80 or DN100 in PN40
Extended diaphragm lengths 2, 4 or 6 inch (50, 101 or 152 mm)
Flange material Zinc-chromate plated carbon steel, 304 SS or 316 SS
Process interface temperature, rated -40 to 110 degC (-40 to 230 degF)
Process interface temperature, operative limit -40 to 175 degC (-40 to 350 degF)
Fill fluids Silicone 200, CTFE, NEOBEE M-20 or Silicone 704
Net weight, aluminium housing 18 to 32 lb (8.2 to 14.5 kg)
Output / protocols 4 to 20 mA with HART 7 or DE; FOUNDATION Fieldbus

How STF828 differs from other STF800 variants

The STF800 family has four models. The STF828 is the low-range, true-flange (flush or extended diaphragm) version. The STF832 is the same mechanical concept at plus and minus 100 psi (7.0 bar). The STF82F and STF83F are pseudo-flange designs for lower range and higher range, with a 316L stainless mounting flange that is itself process wetted and a lighter body of 14 to 19 lb (6.4 to 8.7 kg).

Performance changes with that mechanical choice. At 80 inH2O the datasheet total-performance figure is 0.436 percent of span for the STF828 against only 0.087 percent for the STF82F, because the longer filled system of a true flange amplifies the temperature effect on a small span. If your tank pressure and fluid temperature are stable and accuracy of the last percent matters, the STF82F will probably do better; if you need 3 or 4 inch flanges, DN-standard flanges, an extended diaphragm that protrudes through insulation, or carbon-steel flanges, the STF828 is the right model.

Pressure ratings and temperature limits for STF828

The maximum allowable working pressure depends on flange class and material. For ANSI Class 150 carbon steel the datasheet shows 285 psi (19.6 bar) at ambient -29 to 38 degC, falling to 245 psi (16.9 bar) at the maximum meter body temperature of 125 degC and 215 psi (14.8 bar) at the process-interface limit of 175 degC. Class 300 carbon steel starts at 740 psi (51.0 bar). PN40 carbon steel starts at 580 psi (40.0 bar). Stainless 316 versions start lower: 275 psi (19.0 bar) for Class 150 and 720 psi (49.6 bar) for Class 300.

Always read the rating against both ambient and process-interface temperature, and remember that the Honeywell rating applies to the weakest of the flange, the process interface and the meter body. Minimum absolute pressure is 25 mmHg (13 inH2O absolute), with short-term exposure down to 2 mmHg permitted for two hours at 70 degC.

Mounting and commissioning a STF828 on a tank

  • Specify the flange bolting circle and rating of the tank nozzle before ordering, because the mounting flange of the transmitter must match it.
  • Fit the gasket recommended for your process; standard adapter seals are glass-filled PTFE, with Viton and graphite as options.
  • Tighten bolts in a star pattern to avoid distorting the diaphragm, which would show up as zero shift.
  • Make the zero adjustment with the tank at a known level, ideally empty, because the capillary-free construction fixes the transmitter at the nozzle height.
  • Use the low-side connection (quarter-inch NPT, half-inch NPT with an adapter, or DIN) to reference the vapour space on closed tanks; leave it open to atmosphere on vented tanks.
  • Configure level in engineering units through the display, handheld or Field Device Manager.

Typical uses of the STF828 in Gulf industry

In Oman you will find flange-mounted transmitters on atmospheric storage tanks for diesel, naphtha and chemicals, on condensate drums, on amine and glycol contactors, on desalination chemical-dosing tanks, and on process vessels with sticky or crystallising liquids. The extended-diaphragm option on the STF828 lets the sensing diaphragm sit flush with the inside wall when the nozzle is long or insulated, which prevents stagnant product in the nozzle from distorting the reading.

Care and diagnostics for the STF828

The ST 800 diagnostic suite reports electronics faults, meter body memory corruption, sensor communication timeout, sensor over-temperature, tamper attempts and display faults. A plugged impulse line detection option exists for the STF800 family, and dual or triple calibration is available for HART and Fieldbus units, with calibrations stored in the meter body. Honeywell recommends re-verifying calibration at a defined interval; confirm the interval in your own maintenance plan.

Inspect the flange face and diaphragm during tank turnarounds. Never press on or probe the diaphragm of the STF828: the thin metal membrane is the sensing element, and a dent will change the calibration.

Ordering the STF828

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Flanged level transmitters are built to order. For a quotation on the STF828 please supply flange size, rating and material, diaphragm material, extended-diaphragm length, fill fluid, protocol, display and housing.

Documents and quotation

The Honeywell STF800 specification 34-ST-03-87 is attached as the datasheet for the STF828. Send an RFQ with the part number STF828, the quantity, and the details above, and we will answer with availability and lead time.

Other Models in the Honeywell Stf800 Range

Seven Star LLC supplies models from the Honeywell Stf800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STF832 SmartLine Flange-Mounted Level Transmitter, 100 psiPressure TransmittersView details
Honeywell STF82F SmartLine Pseudo-Flange Level TransmitterPressure TransmittersView details
Honeywell STF828 SmartLine Flange-Mounted Level TransmitterPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Honeywell STF828 SmartLine Flange-Mounted Level Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STF828 SmartLine Flange-Mounted Level

Answers from our engineering team on installation, compatibility and integration.

01What is the measuring range of the Honeywell STF828?
The STF828 covers plus and minus 400 inH2O (plus and minus 1000 mbar) with a minimum span of 4 inH2O (10 mbar) and turndown up to 100:1.
02What flange sizes can the STF828 be ordered with?
2, 3 and 4 inch ANSI Class 150 or 300, or DN50, DN80 and DN100 in PN40; extended diaphragms come in 2, 4 and 6 inch lengths.
03How does the STF828 differ from the STF82F?
The STF82F is a pseudo-flange design with a process-wetted 316L flange and 2 or 3 inch Class 150 connection; its total performance is 0.087 percent of span at 80 inH2O against 0.436 percent for the STF828.
04What is the maximum process temperature of the STF828?
Rated process interface temperature is -40 to 110 degC (-40 to 230 degF) and the operative limit is 175 degC (350 degF).
05What does the STF828 weigh?
With the aluminium housing the STF828 weighs 18 to 32 lb (8.2 to 14.5 kg), depending on flange size and rating.