- Automation & ControlView all 2,803 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Honeywell
Honeywell STA745 SmartLine ST 700 Absolute Transmitter, 500 psia
Description
STA745: the mid-range absolute transmitter in Honeywell ST 700
For 500 psia (35 barA) absolute measurement on a HART loop, Honeywell offers the STA745. The lower range limit is zero, the minimum span is 5 psia (0.35 barA), and the maximum turndown is 100:1. It uses the same dual-head construction as the STA725 but a stronger sensor, and its reference turndown of 16.7:1 means the stated accuracy of 0.065 percent of span holds down to a span of about 30 psia (2.1 barA) before the turndown term takes effect.
That combination makes the STA745 the workhorse of the ST 700 absolute line. It covers compressor suction and discharge, steam and boiler-feed headers, vessel pressure on reactors, and any process that cares about absolute pressure but does not need the extra performance of the ST 800.
STA745 datasheet extract
| Parameter | Value |
|---|---|
| Upper range limit | 500 psia (35 barA) |
| Lower range limit | 0 psia |
| Minimum span | 5 psia (0.35 barA) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.065 percent of span |
| Stability | 0.02 percent of URL per year over 10 years |
| Reference turndown | 16.7:1 |
| Breakpoint span C | 30 psia (2.1 barA) |
| Total performance example | 0.163 percent of span at 100 psia, 5:1 turndown, 50 degF shift |
| MAWP | 500 psia (35 barA) |
| Meter body temperature, rated | -40 to 110 degC (-40 to 230 degF) |
| Meter body temperature, operative | -40 to 125 degC (-40 to 257 degF) |
| Response time | 100 ms |
| Fill fluid | Silicone 200 or CTFE |
| Process connection | Half-inch NPT female |
| Weight | 8.3 lb (3.8 kg) |
Selecting between STA745, STA74S and STA745 alternatives
The STA74S has the same 500 psia range and the same 100:1 turndown as the STA745 but uses the in-line body, so it weighs 3.6 lb (1.6 kg) and accepts half-inch NPT male, 9/16 Aminco and G half-B threads. Its total performance at 100 psia is 0.187 percent, slightly worse than 0.163 percent for the STA745. Choose the STA745 where you want a bracket-mounted dual-head with vent and drain valves, or where you may need to change the head material between carbon steel, 316 stainless and Hastelloy.
Choose the STA725 below one atmosphere, and the STA77S above 500 psia. For tighter accuracy or other protocols, move to the ST 800 equivalent, the STA840, which offers 0.030 percent accuracy and 200:1 turndown.
Process heads, gaskets and bolting on the STA745
The dual-head STA745 offers process heads in zinc-plated carbon steel, 316 stainless steel or Hastelloy C-276, barrier diaphragms in 316L stainless or Hastelloy C-276, vent and drain valves in 316 stainless or Hastelloy, head gaskets in glass-filled PTFE (Viton or graphite optional), and bolting in zinc-plated carbon steel with 316, NACE A286 or Super Duplex options. In sour service, choose NACE-compliant bolting and a Hastelloy or stainless head.
The housing is polyester-coated low-copper aluminium, Type 4X and IP66/IP67, with a stainless housing optional.
Typical STA745 duties in Gulf plants
Gas-processing plants in Oman use absolute transmitters on compressor suction drums, where the reading must stay meaningful when the inlet pressure falls close to atmospheric during turndown. Power stations use them on low-pressure feedwater heaters and deaerators. Refineries and petrochemical units fit them to reactor and column overhead lines. Water and desalination plants use them on brine heater shells and steam ejector inlets, and factories apply them on vacuum-assisted drying and sterilisation equipment.
Since the process span of these services is usually well inside 500 psia, the 100:1 maximum turndown lets one stocked unit cover several loops, provided the accuracy at each span is acceptable.
Wiring and set-up of STA745
- Connect the loop to the polarity-insensitive terminals with up to 16 AWG conductors.
- Check supply of 10.8 to 42.4 VDC with load of 0 to 1,440 ohms; intrinsically safe loops are limited to 30 VDC.
- Trim zero against a stable absolute reference such as a barometer-corrected reference or a vacuum-referenced controller.
- Select the damping time (0 to 32 seconds, default 0.5 seconds).
- Choose Honeywell standard or NAMUR NE 43 output limits.
Worked accuracy example for the STA745
Take a process that runs between 0 and 100 psia and is configured with the full 500 psia range turned down to a 100 psia span, which is a 5:1 turndown. The datasheet gives a total performance of 0.163 percent of span for that case with a 50 degF (28 degC) ambient shift, which is 0.163 psi in absolute terms. Narrowing the span further to 30 psia (the breakpoint) pushes turndown to 16.7:1; below that the error grows roughly in proportion to the turndown ratio.
A buyer comparing the STA745 with other brands should therefore ask for total performance at the same span and the same temperature shift, rather than comparing reference accuracy alone. Seven Star LLC can help match your operating span to the correct range code, and we are glad to review the loop sheet before you order. Send the process pressure range, the minimum and maximum operating values, and the normal ambient temperature so that the span and breakpoint can be checked against the datasheet.
Maintaining the STA745
Verify calibration every two years, and keep records. Diagnostic indications include meter-body and electronics faults and a sensor communication timeout. Vibration effect is less than plus or minus 0.1 percent of URL without damping, per IEC 60770-1 at high vibration level.
Ordering the STA745 from Seven Star LLC
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For the STA745 please indicate housing, display, approvals, mounting bracket, head and diaphragm material, fill fluid and options such as lightning protection.
Documents and quotation
The Honeywell STA700 specification 34-ST-03-120 is attached as the datasheet for the STA745. Send an RFQ with the part number STA745, the quantity and delivery location in Oman or the GCC, and we will respond with availability and lead time.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a Honeywell STA745 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure transmitters, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Datasheets & Documents
- Datasheet Honeywell STA745 SmartLine ST 700 Absolute Transmitter, 500 psia Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STA745 SmartLine ST 700 Absolute
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STA745?
0 to 500 psia (0 to 35 barA) with a minimum span of 5 psia (0.35 barA) and turndown up to 100:1.
02What is the accuracy of the STA745?
Reference accuracy is 0.065 percent of span; the datasheet total performance is 0.163 percent of span at 100 psia with 5:1 turndown and a 28 degC shift.
03Is the STA745 dual-head or in-line?
The STA745 is the dual-head (7x5) model; the in-line equivalent with the same range is the STA74S.
04Which fill fluids are available on the STA745?
Silicone 200 and CTFE (chlorotrifluoroethylene) are listed for the ST 700 absolute models.
05What communication does the STA745 use?
4 to 20 mA with HART 7, with response time of 100 ms and a 2.5 second turn-on time.