Brand:

Honeywell STF832 SmartLine Flange-Mounted Level Transmitter, 100 psi

Description

Higher-range tank measurement with the Honeywell STF832

Where a tank is deep or the liquid is dense, the range of a 400 inH2O transmitter is not enough. The Honeywell STF832 extends the STF800 flange-mounted line to plus and minus 100 psi (plus and minus 7.0 bar), with a minimum span of 1 psi (0.07 bar) and a maximum turndown of 100:1. A column of water 10 metres high produces roughly 1 bar, so the STF832 handles columns of dense fluid up to many metres, and can be used on pressurised vessels where the vapour-space pressure is subtracted by the high and low side connections.

The mechanical design matches the STF828: a flush or extended diaphragm on a 2, 3 or 4 inch ANSI Class 150 or 300 flange, or a DN50, DN80 or DN100 PN40 flange, in zinc-chromate plated carbon steel, 304 stainless or 316 stainless. Extended diaphragms are 2, 4 or 6 inches (50, 101 or 152 mm) long.

Performance profile of STF832

Parameter Value
Range 100 psi to -100 psi (7.0 bar to -7.0 bar)
Minimum span 1 psi (0.07 bar)
Maximum turndown 100:1
Reference accuracy 0.0375 percent of span standard, 0.0325 percent optional
Stability 0.025 percent of URL per year for 15 years
Reference turndown for accuracy 6.7:1
Total performance example 0.358 percent of span at 20 psi
Meter body temperature -40 to 110 degC rated, up to 125 degC operative
Process interface temperature -40 to 110 degC rated, 175 degC operative limit
Weight 18 to 32 lb (8.2 to 14.5 kg), aluminium housing
Minimum absolute pressure 25 mmHg absolute, short term 2 mmHg

STF832 compared with STF828, STF82F and STF83F

The four STF800 models are split on two axes: range and flange construction. Range is low (plus and minus 400 inH2O) on the STF828 and STF82F, and high (plus and minus 100 psi) on the STF832 and STF83F. Flange is true flange on the STF828 and STF832, and pseudo flange on the STF82F and STF83F. So the STF832 is the high-range true flange. Its stability, at 0.025 percent of URL per year, is weaker than the 0.01 figure of the low-range models, and its optional accuracy is 0.0325 percent where the low range reaches 0.025 percent.

Its total performance at 20 psi is 0.358 percent of span, whereas the STF83F delivers 0.074 percent at the same point. That tells you that on a pressurised vessel needing tight accuracy over a modest span, the pseudo-flange STF83F may serve better; if you need the larger flange sizes, higher process temperature or carbon steel flange, the STF832 remains the choice.

Using the STF832 on pressurised vessels

On a closed vessel the high side senses tank liquid plus gas pressure and the low side senses gas pressure alone, usually through a wet or dry leg. The STF832 reads the difference, which is the head of liquid. Keep the low-side leg dry on clean gas and filled on condensing vapours, and enter the leg correction at commissioning. Vessel pressure up to the flange rating can be applied: for Class 300 carbon steel the datasheet gives 740 psi (51.0 bar) in the cold range.

Set the 4 mA point at the lower tap level when you configure the range. If the density of the process changes, reconfigure the span, because the signal is proportional to the density times the height.

Installation notes for the STF832

  • Confirm that the flange class, face and bolting match the nozzle.
  • Select the fill fluid to match your temperature: Silicone 704 needs a minimum of 0 degC; CTFE is rated to -40 degC; NEOBEE M-20 has a minimum of -15 degC.
  • Use the adapter flange option for half-inch NPT access on the low side when needed.
  • Carry out a pressure test of the whole assembly to the flange rating before introducing the fluid.
  • Record the nameplate model and range in the loop file.

Sizing example for a STF832 tank installation

Suppose a closed vessel holds a liquid of specific gravity 0.85 and the level range between the lower and upper taps is 3 metres. The differential head is about 3 times 0.85 times 0.0981, roughly 0.25 bar or 3.6 psi, comfortably above the 1 psi minimum span and well below the plus and minus 100 psi limit. The reference turndown of 6.7:1 corresponds to a 15 psi (1.05 bar) span, so a 3.6 psi span is below that break point and the turndown term of the datasheet accuracy equation applies. If the process is a light hydrocarbon with a specific gravity near 0.5 over a 2-metre range, the span would be only about 0.098 bar (1.4 psi), close to the 1 psi minimum, and the temperature effect would matter more.

Doing this check before ordering helps you choose between this model and the low-range STF828 at 400 inH2O, which converts to about 14.5 psi each side of zero.

Service life and spares for the STF832

The 15-year warranty extension is available on ST 800 products, and the unit is built for field replacement of display, electronics and meter body. Honeywell advises that diagnostics, including plugged impulse line detection, help find problems before they become failures. Keep a spare electronics module and gasket set on site.

Ordering the STF832

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Specify the flange, diaphragm, fill fluid, protocol and housing for the STF832 so that we can match the ordering code exactly.

Documents and quotation

The Honeywell STF800 specification 34-ST-03-87 is attached as the datasheet for the STF832. Send an RFQ with the part number STF832, the quantity and the delivery location, and we will reply with availability and lead time.

Selection Notes for the Honeywell STF832

When comparing the Honeywell STF832 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Honeywell pressure transmitters range and confirm the correct order code before you commit.

Other Models in the Honeywell Stf800 Range

Seven Star LLC supplies models from the Honeywell Stf800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STF832 SmartLine Flange-Mounted Level Transmitter, 100 psiPressure TransmittersYou are viewing this model
Honeywell STF82F SmartLine Pseudo-Flange Level TransmitterPressure TransmittersView details
Honeywell STF828 SmartLine Flange-Mounted Level TransmitterPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Honeywell STF832 SmartLine Flange-Mounted Level Transmitter, 100 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STF832 SmartLine Flange-Mounted Level

Answers from our engineering team on installation, compatibility and integration.

01What is the pressure range of the Honeywell STF832?
The STF832 measures plus and minus 100 psi (plus and minus 7.0 bar) with a minimum span of 1 psi (0.07 bar), giving turndown of up to 100:1.
02How stable is the STF832?
The datasheet states 0.025 percent of URL per year for 15 years for the STF832 and STF83F, compared with 0.01 percent for the two low-range STF models.
03What accuracy does the STF832 offer?
Standard reference accuracy is 0.0375 percent of span, optional 0.0325 percent, and total performance at 20 psi is 0.358 percent of span.
04Which flange options exist for the STF832?
2, 3 or 4 inch ANSI Class 150 or 300, and DN50, DN80 or DN100 PN40, flush or extended diaphragm of 2, 4 or 6 inches.
05Which fill fluids does the STF832 use?
Silicone 200, CTFE, NEOBEE M-20 or Silicone 704; the minimum temperature is 0 degC for Silicone 704, -15 degC for NEOBEE and -40 degC for CTFE.