Brand: Honeywell
Honeywell STG840 Gauge Pressure Transmitter, 500 psi
Description
Honeywell STG840 overview
The Honeywell STG840 is a SmartLine ST 800 gauge pressure transmitter that combines a piezoresistive sensor with on-chip temperature compensation. It covers -14.7 to 500 psi (-1.01 to 34.47 bar), the most widely applicable range of the gauge family. It is fully tested for compatibility with Experion PKS, so it is a frequent replacement or expansion item for plants that run Honeywell control systems.
The Honeywell STG840 is a general purpose choice for pump discharge, compressed air, steam condensate, hydraulic and utility header pressure. Seven Star LLC lists the STG840 for plants in Oman and the GCC that need the exact model number to match an existing instrument index or spare parts list.
Key features of the STG840
- Piezoresistive sensing with on-chip temperature compensation, giving high accuracy and stability across the rated range.
- 4 to 20 mA output with Honeywell DE, HART version 7 or FOUNDATION Fieldbus, all with polarity-insensitive wiring.
- Response time of 80 ms for DE and HART and 150 ms for FOUNDATION Fieldbus (host dependent).
- Rangeability up to 200 to 1 and stability up to 0.01% of URL per year for 15 years across the family.
- Standard LCD or advanced graphics LCD, three-button local configuration, and modular electronics, display and meter body.
- Plugged impulse line detection option, dual or triple calibration for HART and Fieldbus, and NAMUR NE-107 extended diagnostics.
- Integral dual seal design, listed compliance with SIL 2/3 requirements, and an optional extra 15-year warranty.
The STG840 shares its electronics, displays and diagnostics with the other STG800 models, so the model number mainly decides the range, the working pressure and the overpressure rating.
STG840 technical specifications
The table below summarises the values published by Honeywell for the STG840. Where a value depends on the communication protocol, the housing or an ordering option, the entry says so, and the full model selection guide in the datasheet remains the reference for exact option codes.
| Parameter | Value |
|---|---|
| Model | STG840 |
| Measurement | Gauge pressure, piezoresistive sensor |
| Upper range limit (URL) | 500 psi (34.47 bar) |
| Lower range limit (LRL) | -14.7 psi (-1.01 bar) |
| Maximum turndown ratio | 200:1 |
| Reference accuracy, % of span | 0.030 standard, 0.025 optional |
| Family stability | Up to 0.01% of URL per year for 15 years |
| Response time | 80 ms (DE and HART); 150 ms (FOUNDATION Fieldbus, host dependent) |
| Output and protocols | Two-wire 4 to 20 mA with DE or HART 7; FOUNDATION Fieldbus ITK 6.0.1 compliant |
| Supply voltage | HART: 10.8 to 42.4 VDC at terminals (intrinsically safe versions limited to 30 VDC); DE: 15 to 49.3 VDC; Fieldbus: 9.0 to 32.0 VDC |
| Maximum allowable working pressure | 500 psi (35 bar) |
| Overpressure | 1500 psi (103 bar) |
| Rated ambient temperature | -40 to 85 °C (-40 to 185 °F) |
| Rated meter body temperature | -40 to 110 °C (-40 to 230 °F) |
| Fill fluid | Silicone 200, CTFE, NEOBEE M-20 or Silicone 704 |
| Process connection | 1/2 inch NPT female, DIN 19213 (standard) |
| Housing | Low-copper aluminium, Type 4X, IP66 and IP67; all-stainless-steel housing optional |
| Net weight | 8.3 lb (3.8 kg) |
Honeywell gives a total performance example for this model: the STG840 at 100 psi reaches 0.054% of span for standard accuracy, 5 to 1 turndown and a temperature shift of up to 50 °F. Total performance is the square root of the sum of squares of accuracy and temperature effect. Calibration verification is recommended every four years. The no-burst pressure is 3 times MAWP for ratings up to 2,000 psi and 2.5 times MAWP plus 1,000 psi above that.
Typical applications in Oman and the GCC
A gauge pressure transmitter reports line or vessel pressure relative to atmosphere. The STG840 is typically specified for the following duties.
- Oil and gas: wellhead and separator monitoring, custody-adjacent flow measurement loops, compressor suction and discharge duties, and fuel gas skids.
- Utilities and power: boiler drum and feedwater measurements, steam header monitoring, condenser and cooling-water loops, and fuel supply lines.
- Water and wastewater: pump station discharge pressure, filter differential monitoring, desalination feed and reject lines, and pipeline surge surveillance.
- Manufacturing and process plants: utility headers, compressed air and steam distribution, chemical dosing skids, and packaged equipment where a smart HART or fieldbus device is specified.
Pump discharge, compressed air and utility headers are the most common uses for this range. The STG840 housing is rated Type 4X, IP66 and IP67 and the ambient limit is -40 to 85 °C, which supports outdoor installation in hot and humid coastal sites when sunshades and gland practice are correct.
Selection and compatibility notes for the STG840
Choose the STG840 when your maximum process pressure, including expected transients, stays inside 500 psi (34.47 bar) and the maximum allowable working pressure of 500 psi (35 bar). Zero and span can be set anywhere within the range limits, and a lower range with high turndown gives the best accuracy at the working point.
Choose the protocol next. Honeywell lists DE, HART 7 and FOUNDATION Fieldbus for the family. Specify it in the RFQ so the correct electronics module is quoted with the STG840.
Wetted materials matter. Barrier diaphragms are listed in 316L stainless steel, Hastelloy C-276, Monel 400 and tantalum, with gold-plated options, and process heads in carbon steel, 316 stainless steel, Hastelloy C-276 or Monel 400. Carbon steel heads are zinc plated and not recommended for water service.
If you are replacing another instrument, send the existing nameplate data, calibrated range, process connection and approval marking so we can match the STG840 correctly.
Installation and commissioning
Mount the STG840 on a 2 inch pipe with the bracket or on a flat surface. Use a block valve and a vent or test connection so the transmitter can be isolated and checked in service. Keep the impulse tube short and avoid trapped condensate or gas pockets that would add static head error.
Connect the loop with up to 16 AWG wire. The terminals are polarity insensitive. Check the supply at the terminals against the voltage range for the selected protocol and remember the load resistance limit for HART and DE.
At commissioning, apply atmospheric pressure to the STG840 for a zero check, set the lower and upper range values, confirm damping and run a loop test. With the optional display and buttons, basic range, units, loop test and zero or span can be set locally. Keep the final configuration record.
Maintenance and diagnostics
The STG840 reports critical diagnostics such as electronics module faults, memory or configuration corruption and sensor communication timeout, and non-critical ones such as display failure and sensor over-temperature. These can be read through DD, DTM or FDI tools or the display.
Modular construction allows replacement of the meter body, electronics or display without disturbing the other parts, and field replacement is permitted in all electrical environments except flameproof. Record the meter body serial number of each STG840 unit on your spares list.
Routine work is a periodic zero check, inspection of housing seals and cable glands, a check of the process connection for leaks, and a documented calibration verification at your site interval.
Related products and ordering notes
Buyers of the STG840 often also order manifolds, mounting brackets or a Honeywell differential transmitter such as the STD810, STD815, STD820, STD830 or STD870 for flow and level loops. Other gauge models in the same family are the STG830, STG840 and STG870.
For temperature measurement alongside, Honeywell offers the STT850 SmartLine temperature transmitter. Send the full list in one RFQ and quote the part number STG840 for this item.
Frequently asked questions in brief
The questions below cover range, overpressure, accuracy and ordering for the STG840, and each answer follows the Honeywell specification.
Documents and quotation
A Honeywell datasheet for the STG840 is attached to this page so your engineers can check ranges, materials and approvals before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request a quotation, send an RFQ that states the part number STG840, the quantity, the measuring range or sensor type, the communication protocol and any display or approval requirement. We will confirm availability and lead time and reply with a written quotation.
Other Models in the Honeywell Stg800 Range
Seven Star LLC supplies models from the Honeywell Stg800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STG830 Gauge Pressure Transmitter, 50 psi | Pressure Transmitters | View details |
| Honeywell STG840 Gauge Pressure Transmitter, 500 psi | Pressure Transmitters | You are viewing this model |
| Honeywell STG870 Gauge Pressure Transmitter, 3000 psi | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Honeywell STG840 Gauge Pressure Transmitter, 500 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STG840 Gauge Pressure Transmitter, 500 psi
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the STG840?
The STG840 has an upper range limit of 500 psi (34.47 bar) and a lower range limit of -14.7 psi (-1.01 bar).
02What is the overpressure limit of the STG840?
Honeywell lists 1500 psi (103 bar) overpressure, with a maximum allowable working pressure of 500 psi (35 bar).
03What accuracy does the STG840 offer?
Reference accuracy is 0.030% of span as standard and 0.025% of span as an option, with turndown up to 200 to 1.
04What response time does the STG840 have?
Response time is 80 ms for DE and HART and 150 ms for FOUNDATION Fieldbus, which depends on the host.
05How do I order the STG840 from Seven Star LLC?
Send an RFQ with the part number STG840, quantity, protocol, display, materials and approvals. We reply with availability and a quotation.


















Reviews