Brand:

Honeywell STA822 SmartLine Absolute Pressure Transmitter, 780 mmHgA

Description

Honeywell STA822 absolute pressure transmitter for deep-vacuum and low-pressure duty

The Honeywell STA822 is the lowest-range member of the SmartLine STA800 absolute pressure family. Its upper range limit is 780 mmHgA, which is 1039.91 mbarA, so the whole span sits at or below roughly one atmosphere absolute. That makes the STA822 a vacuum and near-atmospheric instrument: it reads the pressure inside condensers, deaerators, vacuum distillation overheads, evaporators and flare knock-out drums, referenced to a perfect vacuum rather than to the surrounding air. A gauge transmitter cannot do this job because its zero moves with the weather; an absolute sensor does not.

The STA822 uses the dual-head body style, with a process head on the high side and a sealed reference on the other, mounted on a stainless-steel or carbon-steel bracket. The sensor is a piezoresistive silicon element with on-chip temperature compensation. Honeywell states a minimum span of 50 mmHgA (66.66 mbarA) and a maximum turndown of 15.6:1, which means the 780 mmHgA ceiling can be re-ranged downwards to a span as narrow as 50 mmHgA without touching hardware.

Key figures that define the STA822

Parameter Value
Model / body style STA822, dual-head absolute (the in-line equivalent is STA82L)
Upper range limit 780 mmHgA (1039.91 mbarA)
Lower range limit 0 mmHgA (0 mbarA)
Minimum span 50 mmHgA (66.66 mbarA)
Maximum turndown 15.6:1
Reference accuracy, percent of span 0.0375 standard, 0.025 optional
Stability 0.010 percent of URL per year, quoted for 15 years
Reference turndown for the accuracy equation 8.6:1
Total performance example 0.253 percent of span at 156 mmHgA, 5:1 turndown, 50 degF (28 degC) shift
Maximum allowable working pressure 780 mmHgA (1,040 mbarA)
Overpressure 1.5 times MAWP
Output and protocols 4 to 20 mA with HART 7, Honeywell DE, or FOUNDATION Fieldbus
Response time 80 ms (HART and DE), 150 ms (Fieldbus, host dependent)
Ambient temperature, rated -40 to 85 degC (-40 to 185 degF)
Net weight, aluminium housing 8.3 lb (3.8 kg)
Calibration verification interval Every four years

How STA822 differs from other STA800 variants

The STA800 family has five models, and the numbers in the name tell you the range. The STA822 reaches 780 mmHgA (1039.91 mbarA). The STA840 reaches 500 psia (34.47 bara) with a 2.5 psia minimum span and 200:1 turndown, and the STA87L reaches 3000 psia (206.84 bara). The STA82L covers the same 780 mmHgA range as the STA822 but in the compact in-line body at 3.6 lb (1.6 kg), and Honeywell lists its stability at 0.015 percent of URL per year instead of 0.010, with no high-accuracy option.

Accuracy is where the STA822 stands apart from its high-range siblings. Its standard reference accuracy is 0.0375 percent of span against 0.030 percent for the STA840, and its example total performance at 5:1 turndown is 0.253 percent of span, whereas the STA840 quotes 0.058 percent at 100 psia. The difference comes from the physics of a very small range: a few mmHg of temperature drift is a large fraction of a 156 mmHgA span. If your process pressure never leaves vacuum, the STA822 is the correct pick; above one atmosphere you should look at the STA840.

Where the STA822 is used in Oman and the GCC

  • Vacuum columns and crude-unit vacuum towers in refineries, where overhead pressure of a few tens of mmHgA sets the cut point.
  • Steam-turbine condenser vacuum monitoring in power and desalination plants, the signal that protects the last-stage blades.
  • Multi-stage flash and multi-effect distillation units on the Gulf coast, where brine-heater and flash-chamber pressure is tracked absolutely.
  • Vacuum degassing, deaeration and freeze-drying lines in food, pharmaceutical and chemical manufacturing.
  • Leak-test and vacuum-hold stations where a barometric swing would otherwise masquerade as a leak.

In a hot GCC climate the STA822 also benefits from its automatic temperature compensation, because outdoor transmitters on vacuum lines routinely see ambient swings from 10 degC at night to above 50 degC in the afternoon sun.

Selection and compatibility notes for STA822

Wetted barrier diaphragms on the STA800 body are offered in 316L stainless steel, Hastelloy C-276, Monel 400, tantalum, and gold-plated versions of the first three. Process heads come in zinc-plated carbon steel, 316 stainless, Hastelloy C-276 or Monel 400, with glass-filled PTFE head gaskets as standard and Viton or graphite as options. Honeywell warns that zinc-plated carbon heads are not recommended for water service because of hydrogen migration; choose a 316 stainless head for condensate and steam condensate lines.

Fill fluid can be Silicone 200, CTFE or Silicone 704. For vacuum work the datasheet reminds users that the transmitter operates within specification above 25 mmHgA (33 mbarA) and that short-term exposure to full vacuum does not cause damage, where short term means two hours at 70 degC. Process connection is half-inch NPT female or DIN 19213. Decide the protocol first: HART 7 loops run on 10.8 to 42.4 VDC with up to 1,440 ohms of load, DE loops on 15 to 49.3 VDC with up to 1,200 ohms, and Fieldbus on 9.0 to 32.0 VDC.

Installing and commissioning the STA822

Mount the STA822 above the tap on a vacuum line where condensate cannot collect in the impulse tubing, and slope the line continuously back to the process. Any liquid trapped in an absolute-vacuum impulse line creates a head error that is large relative to a span of 50 to 150 mmHgA. After tightening the half-inch NPT connection, do a leak check, because a tiny air ingress on a vacuum line shows up as a slow upward drift.

Configure range through the external three-button interface, a handheld communicator, or Field Device Manager. The three buttons work even in hazardous areas when a display is fitted, and they can also be set up for zero and span. Set damping with care: HART damping is adjustable from 0 to 32 seconds in 0.1 second steps with a 0.5 second default, and DE uses discrete values from 0 to 32 seconds with a 0.48 second default. Optionally enable the plugged impulse line detection feature, which is useful on dirty vacuum services.

Maintenance, diagnostics and spares for the STA822

Honeywell recommends calibration verification every four years for the STA800 family. Between checks the transmitter reports critical diagnostics such as electronics module fault, meter body memory corruption, configuration data corruption and sensor communication timeout, plus non-critical ones including display failure, sensor over temperature, PV out of range and tamper attempt. The device supports NAMUR NE-107 extended diagnostics over HART and Fieldbus.

Because the design is modular, the meter body, the electronics and communications module, the display and the lightning-protection terminal block can each be replaced in the field without invalidating performance, and without violating agency approvals in every environment except flameproof. For a plant with several STA800 units, stocking one spare electronics module and one spare meter body covers most failures. Quote the STA822 exactly when you need a replacement meter body so the correct characterisation is matched.

Related products and ordering the STA822

Plants that run the STA822 often also hold the STA840 for higher-pressure absolute service, and Honeywell STD800 differential or STG800 gauge units on adjacent loops. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; our role is to source the exact model you specify. Because the STA822 is a model family code, please also send the full order code from your old tag or purchase record: protocol, display, housing, approvals, bracket and fill fluid.

Frequently asked questions

The short answers below summarise the most common questions about the STA822: its 780 mmHgA range, 15.6:1 turndown, 0.0375 percent standard accuracy and four-year calibration interval. Detailed questions are listed in the FAQ block of this page.

Documents and quotation

The Honeywell technical specification 34-ST-03-85 covering the STA822 is attached to this page as a datasheet. To receive a quotation, send an RFQ to Seven Star LLC with the part number STA822, the quantity required, the communication protocol, the display and housing option, and the hazardous-area approval you need. We reply with availability and lead time.

Other Models in the Honeywell Sta800 Range

Seven Star LLC supplies models from the Honeywell Sta800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STA840 SmartLine Absolute Pressure Transmitter, 500 psiaPressure TransmittersView details
Honeywell STA87L In-Line Absolute Pressure Transmitter, 3000 psiaPressure TransmittersView details
Honeywell STA822 SmartLine Absolute Pressure Transmitter, 780 mmHgAPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Honeywell STA822 SmartLine Absolute Pressure Transmitter, 780 mmHgA Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STA822 SmartLine Absolute Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the pressure range of the Honeywell STA822?
The STA822 spans 0 to 780 mmHgA (0 to 1039.91 mbarA) with a minimum span of 50 mmHgA (66.66 mbarA), so it covers vacuum up to roughly one atmosphere absolute.
02How accurate is the STA822?
Reference accuracy is 0.0375 percent of span as standard, or 0.025 percent with the optional high-accuracy calibration. The datasheet total-performance example is 0.253 percent of span at 156 mmHgA.
03Is the STA822 dual-head or in-line?
The STA822 is the dual-head absolute model with a 3.8 kg (8.3 lb) body. The same 780 mmHgA range in a lighter in-line body is the STA82L at 1.6 kg.
04Which protocols and supply voltages does the STA822 support?
4 to 20 mA with HART 7 on 10.8 to 42.4 VDC, Honeywell DE on 15 to 49.3 VDC, or FOUNDATION Fieldbus on 9.0 to 32.0 VDC, all with polarity-insensitive wiring.
05How often should the STA822 be calibrated?