STA87L: Honeywell high-pressure in-line absolute transmitter

The STA87L is the high end of the STA800 family. Honeywell specifies an upper range limit of 3000 psia (206.84 bara), a lower limit of zero, and a minimum span of 15 psia (1.03 bara), which gives a turndown of up to 200:1. Unlike the bracket-mounted STA822 and STA840, the STA87L belongs to the STA80L in-line group: a compact body in which the process connection is threaded directly into the bottom of the sensor module. The result is a transmitter that weighs only 3.6 lb (1.6 kg) with an aluminium housing, compared with 8.3 lb (3.8 kg) for the dual-head versions.

High absolute pressure is typical of hydraulic test rigs, gas storage and injection skids, compressed-natural-gas systems, high-pressure steam and process air headers. In these applications a gauge transmitter would be perfectly acceptable if the plant never cared about 14.7 psi of atmosphere; the STA87L is chosen when it does.

STA87L data at a glance

Parameter Value
Model STA87L, in-line absolute (STA80L group)
Upper range limit 3000 psia (206.84 bara)
Lower range limit 0 psia
Minimum span 15 psia (1.03 bara)
Maximum turndown 200:1
Reference accuracy, percent of span 0.030 standard, 0.025 optional
Stability 0.010 percent of URL per year over 15 years
Reference turndown 10:1
Total performance example 0.067 percent of span at 600 psia, 5:1 turndown, 50 degF (28 degC) shift
Maximum allowable working pressure 3,000 psia (210 barA)
No-burst pressure 2.5 times MAWP plus 1,000 psi, because MAWP is above 2,000 psi
Barrier diaphragm 316L stainless steel or Hastelloy C-276
Process head 316L stainless steel or Hastelloy C-276
Process connections Half-inch NPT female, half-inch NPT male, 9/16 Aminco, DIN 19213, G half-B male
Fill fluid Silicone 200, CTFE or Silicone 704
Weight, aluminium housing 3.6 lb (1.6 kg)

Reading the STA87L against other in-line absolute models

The STA800 in-line family has three members. The STA82L tops out at 780 mmHgA, the STA84L at 500 psia, and the STA87L at 3000 psia. Both it and the STA84L offer the 0.030 standard and 0.025 optional accuracy, but the reference turndown for the accuracy equation is 10:1 on the STA87L in both the standard and high-accuracy versions, whereas the STA84L reaches 25:1 with the high-accuracy option. If your operating pressure is below 500 psia, a lower-range STA84L will give a better absolute error on the same reading.

It also lacks the vent and drain valves, replaceable gaskets and bracket options of the dual-head models, because the in-line design has no process head to open. That is an advantage in high-pressure service where every gasket is a possible leak point, and a disadvantage where the process may plug and need to be cleaned in place.

Installing the STA87L in high-pressure service

Pick the thread that matches your tubing: half-inch NPT female for conventional pipe fittings, half-inch NPT male for direct insertion into a tapping, 9/16 Aminco for ultra-high-pressure tubing, DIN 19213 or G half-B male for European instrument piping. Use thread sealant suited to the process medium and never exceed the MAWP of 3,000 psia when tightening and testing. For hydraulic and gas-injection lines add a snubber or damping setting, because the transmitter can follow very fast transients; Honeywell quotes an 80 ms response for HART and DE.

In-line transmitters hang from the process connection, so support the body when a long impulse tube is used. Orient the housing so that the conduit entries face downwards or sideways in rain-exposed outdoor sites; the aluminium housing is rated Type 4X and IP66/IP67 with silicone cover O-rings.

Sectors using the STA87L in Oman and the GCC

  • Compression and re-injection skids at oil and gas facilities, where discharge pressure may reach several hundred bar absolute.
  • Hydraulic power units and test benches in manufacturing and heavy maintenance workshops.
  • Water-jetting and high-pressure washdown systems used for descaling and desalination plant maintenance.
  • Steam and process-air headers in utilities, where absolute readings help with mass-flow compensation.
  • Gas cylinder fill panels and high-pressure industrial-gas distribution.

Safety, protocol and display options on the STA87L

Like the rest of the ST 800 line, this transmitter is documented for SIL 2/3 use, has an integral dual-seal design based on ANSI/NFPA 70 and ANSI/ISA 12.27.x, and carries an optional lightning-protection terminal block rated for 5000 A at 8/20 microseconds. The loop options are 4 to 20 mA with HART 7, 4 to 20 mA with Honeywell DE, or FOUNDATION Fieldbus ITK 6.0.1, and every protocol uses polarity-insensitive wiring. The Fieldbus version draws a steady 17.6 mA, rising to 27.4 mA during a software download.

The display is either a standard alphanumeric LCD with two lines of six digits or an advanced graphics LCD with up to eight screens, a bar graph or trend graph, and a Health Watch indicator. Three external buttons allow configuration without opening the cover, and the advanced display supports EN, DE, FR, IT, ES, RU, UK, TR, CN and JP languages.

Maintenance and calibration notes for STA87L

Calibration verification is recommended every four years, using a deadweight tester or a pressure controller referenced to absolute pressure. Stability is 0.010 percent of URL per year, so a drift of 0.3 psia per year at most on a 3000 psia range is the design intent; measure it before adjusting. Diagnostic messages cover sensor communication timeout, sensor over temperature, meter body memory corruption and PV out of range, among others.

Ordering the STA87L

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For the STA87L, give us the model string, communication protocol, display, housing material, approvals and desired thread. Replacement of an older ST 3000 absolute transmitter with the STA87L should be agreed with your instrument engineer, since the datasheet does not name a replacement.

Documents and quotation

The Honeywell STA800 specification 34-ST-03-85 is attached as the datasheet for the STA87L. Send an RFQ listing the part number STA87L, the quantity and your delivery location in Oman or the GCC, and we will revert with availability and lead time.

Other Models in the Honeywell Sta800 Range

Seven Star LLC supplies models from the Honeywell Sta800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STA840 SmartLine Absolute Pressure Transmitter, 500 psiaPressure TransmittersView details
Honeywell STA87L In-Line Absolute Pressure Transmitter, 3000 psiaPressure TransmittersYou are viewing this model
Honeywell STA822 SmartLine Absolute Pressure Transmitter, 780 mmHgAPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Honeywell STA87L In-Line Absolute Pressure Transmitter, 3000 psia Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STA87L In-Line Absolute Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum pressure of the Honeywell STA87L?
The STA87L has an upper range limit of 3000 psia (206.84 bara) and a maximum allowable working pressure of 3,000 psia (210 barA), with no-burst at 2.5 times MAWP plus 1,000 psi.
02What process connections can the STA87L use?
Half-inch NPT female, half-inch NPT male, 9/16 Aminco, DIN 19213 and G half-B male threaded fittings are listed for the STA80L in-line family.
03How heavy is the STA87L?
Honeywell lists the STA80L in-line body at 3.6 lb (1.6 kg) with an aluminium housing, much lighter than the 8.3 lb (3.8 kg) dual-head STA800.
04What are the wetted materials of the STA87L?
The barrier diaphragm and process head are available in 316L stainless steel or Hastelloy C-276; the STA87L has no vent or drain valves and no gaskets.
05What accuracy does the STA87L offer?
Standard reference accuracy is 0.030 percent of span and optional is 0.025 percent; the total-performance example is 0.067 percent of span at 600 psia and 5:1 turndown.