Brand: MEDC
MEDC BG2E Break Glass Manual Call Point (Ex de)
Description
The Manual Release MEDC BG2E is a high-performance break glass call point engineered for use in hazardous and potentially explosive atmospheres. Designed by Eaton’s Crouse-Hinds series, this safety device ensures reliable manual activation in emergency situations. With its robust construction and compliance to stringent safety standards, the Manual Release MEDC BG2E is trusted in critical environments where reliability is paramount.
The unit is specifically suitable for both onshore and offshore installations, including oil refineries, gas processing plants, and petrochemical facilities. Its corrosion-resistant Glass Reinforced Polyester (GRP) enclosure provides exceptional durability while keeping the unit lightweight for easier installation. Rated to IP66/67, the Manual Release MEDC BG2E ensures complete protection against dust ingress and high-pressure water jets, making it ideal for challenging environments with exposure to moisture, salt, and extreme weather.
With a maximum voltage of 24 V and a current rating of 0.05 A, this break glass call point delivers safe and efficient operation without compromising system performance. It is designed for use with conventional EX-certified fire and safety systems, ensuring full compliance with ATEX and IECEx requirements for explosive atmosphere safety.
The Manual Release MEDC BG2E features a simple and intuitive manual activation method—breaking the safety glass to trigger an alarm or safety response. This design makes it an essential component in emergency shutdown systems (ESD) and fire alarm networks in hazardous industrial zones.
Applications include oil rigs, LNG plants, chemical storage facilities, power plants, and marine platforms where safety is critical and environmental resistance is non-negotiable. The unit’s compact form factor allows it to be installed in confined spaces, while its bright finish and clear labeling ensure quick identification during emergencies.
Key benefits of the Manual Release MEDC BG2E include:
-
High corrosion resistance thanks to the GRP body.
-
Compliance with international hazardous area safety certifications.
-
IP66/67 protection for operation in harsh outdoor or marine conditions.
-
Simple manual operation for fast emergency response.
-
Low maintenance design with durable components.
Whether you need a dependable manual release unit for offshore oil platforms or a corrosion-resistant call point for industrial facilities, the Manual Release MEDC BG2E offers unmatched reliability, ruggedness, and compliance with global safety standards.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | MEDC (Eaton Crouse-Hinds series) |
| Model | BG2E (BG2 range) |
| Product Type | Manual release call point (break glass unit) |
| Ex Ratings | Ex db eb IIC T6 Gb (Ex de version, Zone 1/2); Ex ia IIC T4 Ga (Ex ia version, Zone 0) |
| Enclosure | Anti-static, UV-resistant glass-reinforced polyester (GRP), red painted finish |
| Ingress Protection | IP66 and IP67 |
| Contact Ratings | 30 Vdc at 5A resistive or 3A inductive; 250 Vac at 5A resistive or inductive |
| Terminals | Six 2.5 mm² field-wiring terminals |
| Options | End-of-line resistor, in-line resistor, or resistor/diode package |
| Operating Temperature | −40°C to +70°C |
Technical Overview
The MEDC BG2E is a manual release call point (break glass unit) from the MEDC BG2 range, now manufactured under Eaton’s Crouse-Hinds series following Eaton’s acquisition of MEDC. Per the official Eaton/Crouse-Hinds datasheet (DSMC0006-EN), the BG2 range is certified for use in hazardous areas, with two principal electrical configurations available: an Ex de version rated Ex db eb IIC T6 Gb, suitable for ATEX Category 2GD applications (Zone 1/2), and an Ex ia intrinsically-safe version rated Ex ia IIC T4 Ga, suitable for ATEX Category 1GD applications (Zone 0) — meaning the BG2 range as a whole can be specified across the full spectrum of hazardous area zones from the most demanding Zone 0 down to Zone 2, depending on which configuration is ordered. Both AC and DC electrical versions are available.
The housing is constructed from anti-static, UV-resistant glass-reinforced polyester (GRP) with a red painted finish, giving the unit strong corrosion resistance for offshore platforms as well as onshore oil, gas, and petrochemical installations, while remaining lightweight compared to a metal-bodied alternative. The unit carries an IP66 and IP67 ingress protection rating, and provides contact/switch ratings of 30 Vdc at 5A resistive or 3A inductive, or 250 Vac at 5A resistive or inductive, with six 2.5 mm² field-wiring terminals for connection. Optional configurations include an end-of-line resistor, an in-line resistor, or a combined resistor/diode package, allowing the call point to be integrated into a variety of fire and gas alarm loop monitoring architectures. Operating temperature range is −40°C to +70°C, supporting deployment across the wide ambient temperature swings found in Gulf region outdoor industrial installations.
Applications
The BG2E manual call point is installed as part of fire and gas detection and alarm systems in hazardous industrial environments — offshore oil and gas platforms, onshore process plants, and petrochemical facilities — providing personnel with a manually-operated means to trigger a plant alarm or emergency shutdown sequence directly from the field, wherever a flammable atmosphere may be present.
Why Seven Star LLC
Seven Star LLC supplies genuine MEDC/Eaton Crouse-Hinds BG2 range manual call points to customers across Oman and the GCC, and helps confirm the correct hazardous-area zone rating, electrical configuration, and resistor/diode option for a specific fire and gas system design before order confirmation.
Request a Quote for MANUAL RELEASE’’MEDC’’SERIES:BG2E
Contact Seven Star LLC to request a quotation for the MEDC BG2E manual release call point. Our team can help confirm the correct hazardous-area certification and electrical configuration for your fire and gas system, and support reliable delivery across Oman and the wider GCC region.
Ordering Notes
When requesting a quotation, please specify the hazardous-area zone classification of the installation location (Zone 0, 1, or 2), the required electrical version (AC or DC), and the resistor/diode configuration needed to integrate with your existing fire and gas alarm control panel, so Seven Star LLC can confirm the correct BG2E configuration for your system.
Offshore and Coastal Durability
The BG2E’s GRP housing and IP66/67 ingress protection make it particularly well suited to Oman’s coastal and offshore installations, where salt-laden air and high humidity can accelerate corrosion on metal-bodied alarm devices over time. Seven Star LLC recommends the GRP-bodied BG2 range specifically for offshore platforms and coastal onshore facilities where long-term corrosion resistance is a priority alongside hazardous-area certification.
Related Products
Datasheets & Documents
- Brochure MEDC MANUAL RELEASE’’MEDC’’SERIES:BG2E Catalog Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
MEDC is a British brand of alarm, signalling and control equipment for hazardous areas, designing and building products for flammable atmospheres and harsh conditions since 1975. It is now part of Eaton, whose Crouse-Hinds hazardous-area portfolio includes the MEDC range alongside the Fulleon and Wheelock signalling brands. MEDC sounders, beacons and call points are used offshore, in refineries and on railways.
Seven Star LLC is an independent supplier listing MEDC explosion-protected beacons, alarm sounders, call points and junction boxes for fire and gas systems in Oman and the GCC.
MEDC company profile
| Active since | 1975, United Kingdom |
|---|---|
| Ownership | Eaton, within its Crouse-Hinds hazardous-area business |
| Sister brands | Fulleon and Wheelock signalling, Cooper and Menvier |
| Approvals | ATEX and IECEx Ex d, Ex de and Ex ia versions |
| Product families | DB3 and XL sounders, SM87 and XB beacons, BG and GP manual call points and break-glass units, combined sounder-beacons, telephone and PA loudspeakers for Zone 1 and Zone 2 |
Milestones
- 1975: MEDC starts designing alarm and signal equipment for hazardous areas.
- 2012: Eaton acquires Cooper Industries, then the owner of MEDC.
MEDC product families on this page
Visual signals include the XB15 xenon beacon, the LD15 LED beacon and the SM87 beacon family with its SM87LED version, for Zone 1 and Zone 2 areas. The DB3 is the alarm sounder. Manual alarm devices are the BG manual call point and a manual release unit from the BG2 call point series, listed as BG2E. The SM87JB junction box completes the field wiring. These devices are ordered with long codes such as SM87BGLAD1T1B1NNRAS or BGEB4B6B1DDCF7R, in which each block of characters selects an option.
Where MEDC signaling equipment is used
MEDC beacons and sounders announce fire, gas and process alarms on production platforms, in gas plants, refineries, chemical plants, loading terminals and marine vessels. Call points give personnel a way to raise the alarm by hand, and the same devices are wired into fire and gas panels from many system builders.
MEDC products we list
Ordering MEDC beacons and call points: what we need
The complete order code from the label or the project datasheet is the best starting point. If you are selecting from scratch, send the supply voltage, lens color for beacons, tone and sound level for sounders, enclosure material and finish color, cable entry size and number, the certification required and the ambient temperature. For call points add the switch arrangement, any series or end-of-line resistor values, and label or duty plate text.
Facts checked against Eaton's alarms and signalling pages and the MEDC catalogue, October 2026.
Browse MEDC products by category: Fire & Gas Systems, Fire & Gas Detector, Automation Accessories.
Related products
Frequently Asked Questions
It is ATEX and IECEx certified for use in explosive atmospheres, making it suitable for conventional Ex-certified fire and safety systems on oil, gas, and petrochemical installations.
It uses a manual break-glass mechanism: operators break the integral safety glass element to trigger the alarm or emergency shutdown (ESD) signal, giving a fast, unambiguous manual activation method.
The call point operates at a maximum of 24V with a current rating of 0.05A, matching typical conventional fire panel initiating-circuit requirements.
It carries an IP66/67 rating, protecting against dust ingress and both high-pressure water jets and temporary immersion, which suits exposed offshore platforms and marine environments.
It uses a Glass Reinforced Polyester (GRP) enclosure, which resists corrosion from salt spray and chemical exposure while remaining lightweight for straightforward installation on rigs, refineries, and marine platforms.