Honeywell STG745 SmartLine STG700 Gauge Pressure Transmitter
Description
Overview of the Honeywell STG745
Honeywell STG745 is the general-purpose workhorse of the STG700 gauge line. Its 500 psi (35 bar) upper range limit covers the bulk of process pressure points on pump discharge, compressor interstage and steam lines, and the minimum span of 5 psi (0.35 bar) still lets a 0 to 50 psi loop be configured at 10:1.
The STG745 combines the piezoresistive sensor of the SmartLine family with temperature compensation and offers terminal-based accuracy of up to 0.065 percent of span and 100:1 turndown. Its total-performance figure in the datasheet, 0.154 percent of span at 100 psi with a 28 degC shift, is a handy benchmark when comparing quotes for similar 500 psi transmitters.
STG745 feature highlights
- Range from minus 14.7 psi to 500 psi (minus 1.0 to 35 bar).
- Reference turndown 20:1 with knee C of 25 psi (1.75 bar).
- Temperature effect 0.075 plus 0.013 times URL over span per 28 degC.
- Stability of 0.020 percent of URL per year over ten years.
- Dual-head body with 1/2-inch NPT female connection, or inline thread options per the datasheet.
Datasheet values for STG745
| Parameter | Value |
|---|---|
| Model | STG745 (STG700 SmartLine gauge pressure) |
| Upper range limit | 500 psi (35 bar) |
| Lower range limit | -14.7 psi (-1.0 bar) |
| Minimum span | 5 psi (0.35 bar) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.065 percent of span (A 0.005, B 0.060) |
| Accuracy knee C | 25 psi (1.75 bar) |
| Temperature effect | 0.075 + 0.013 x URL/span, percent of span per 28 degC |
| Total performance example | 0.154 percent of span at 100 psi |
| Stability | 0.020 percent of URL per year, quoted over ten years |
| MAWP | 500 psi (35 bar) |
| Output / protocol | Two-wire 4 to 20 mA with HART 7 |
| Supply voltage and loop load | 10.8 to 42.4 VDC at the terminals (intrinsically safe versions limited to 30 VDC); load 0 to 1,440 ohms |
| Response time | 100 ms; turn-on time 2.5 s; damping 0 to 32 s, default 0.5 s |
| Rated ambient / meter body temperature | -40 to 85 degC / -40 to 110 degC (operative limit 125 degC) |
| Overpressure | 1.5 x MAWP of the model |
| Process connections | Dual head: 1/2-inch NPT female. Inline: 1/2-inch NPT female or male, 9/16-18 high-pressure cone and thread female, G1/2-B male |
| Wetted diaphragm / head | 316L stainless steel or Hastelloy C-276 diaphragm; heads in carbon steel (zinc plated), 316 SS or Hastelloy C-276 (dual head), 316L SS or Hastelloy C-276 (inline) |
| Fill fluid | Silicone or CTFE |
| Housing | Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional |
| Net weight | Dual head 8.3 lb (3.8 kg); inline 3.6 lb (1.6 kg), with aluminium housing |
How STG745 differs from other STG700 variants
The STG745 differs from the STG735 mainly in capacity: 500 psi against 50 psi, with the minimum span rising from 0.5 psi to 5 psi. Compared with the STG775 it offers a finer 5 psi minimum span and a higher reference turndown of 20:1 versus 8.5:1; the STG775 reaches 3,000 psi (210 bar).
For an application whose normal pressure is 120 psi and whose relief valve is set at 300 psi, the STG745 is the smallest body that covers the relief set point, and the datasheet total performance of 0.154 percent at 100 psi is close to what is obtained at 120 psi.
| Model | URL | Ref. turndown | Temp effect D + E |
|---|---|---|---|
| STG735 | 50 psi | 16.7:1 | 0.070 + 0.008 |
| STG745 | 500 psi | 20:1 | 0.075 + 0.013 |
| STG775 | 3000 psi | 8.5:1 | 0.075 + 0.013 |
Oman and GCC uses for STG745
In the Gulf region the STG745 is frequently found on glycol and amine circulation pump discharge, instrument air headers at 100 to 150 psi, firewater jockey pump discharge and hydraulic power units. Water utilities specify the same range for transfer pump stations and desalination booster pumps. In manufacturing it is used on compressed air and nitrogen distribution.
The transmitter is also employed in test rigs where a 5 psi minimum span lets a single device serve several calibrations.
Selection checklist for STG745
Select the STG745 if maximum pressure including surges is under 500 psi; overpressure capacity is 1.5 times the MAWP. Evaluate wetted materials: 316L stainless steel diaphragms for most hydrocarbon and water duties, Hastelloy C-276 for chloride-rich or acidic media. Verify process connection style; the dual head offers 1/2-inch NPT female, and inline versions offer 1/2-inch NPT male, 9/16-18 cone and thread female or G1/2-B male.
Fill fluids are silicone or CTFE per the datasheet.
Commissioning STG745 step by step
Fit an isolation valve and a test tee to simplify future calibration. For pulsating pump discharge increase damping from the 0.5 s default, since the datasheet allows up to 32 seconds. Maintain at least the 10.8 VDC minimum terminal voltage with the loop load considered, and ground the housing through the external terminal.
After power-up wait 2.5 seconds for self-test, then verify zero and span with a reference gauge.
Maintenance and diagnostics
Plan a verification every two years. If the output sticks at a failure level of 3.6 mA or below, or 21.0 mA or above, the transmitter is reporting a critical fault which can be identified through HART. Replacing the electronics module is a field operation and does not require a new meter body.
Frequently asked about STG745
What is the range of the Honeywell STG745? The STG745 spans minus 14.7 psi to 500 psi (minus 1.0 to 35 bar) with a minimum span of 5 psi (0.35 bar).
What is the turndown of the STG745? Maximum turndown is 100:1, and the reference turndown for stated accuracy is 20:1.
What temperature effect applies to the STG745? The temperature effect is 0.075 plus 0.013 times URL over span, percent of span per 28 degC.
What is the weight of the STG745? Dual head versions weigh 8.3 lb (3.8 kg) and inline versions 3.6 lb (1.6 kg) with aluminium housing.
Is the STG745 available with a stainless steel housing? Yes, the datasheet lists an all-stainless-steel housing as an option to the aluminium housing.
Documents and quotation
The STG700 datasheet 34-ST-03-122 is the reference for STG745 accuracy, approvals and dimensions and can be sent with your quotation.
For Honeywell STG745 pricing, send part number, quantity, range, connection and approval to Seven Star LLC.
Other Models in the STG700 Range
Seven Star LLC supplies models from the STG700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STG735 SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STG745 SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell STG745 SmartLine STG700 Gauge Pressure Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STG745 SmartLine STG700 Gauge Pressure
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STG745?
The STG745 spans minus 14.7 psi to 500 psi (minus 1.0 to 35 bar) with a minimum span of 5 psi (0.35 bar).
02What is the turndown of the STG745?
Maximum turndown is 100:1, and the reference turndown for stated accuracy is 20:1.
03What temperature effect applies to the STG745?
The temperature effect is 0.075 plus 0.013 times URL over span, percent of span per 28 degC.
04What is the weight of the STG745?
Dual head versions weigh 8.3 lb (3.8 kg) and inline versions 3.6 lb (1.6 kg) with aluminium housing.
05Is the STG745 available with a stainless steel housing?
Yes, the datasheet lists an all-stainless-steel housing as an option to the aluminium housing.