Rosemount 08712-0061-0001 is the electrode (signal) cable sold by the foot for the Rosemount 8700 Series magnetic flowmeter system. The datasheet lists it as Electrode Cable, 20 AWG, equivalent to Belden 8762 or Alpha 2411. It carries the tiny millivolt-level flow signal that the sensor electrodes generate to a remote transmitter such as the Rosemount 8712, or to the remote version of the Rosemount 8732. A magnetic flowmeter converts the flow velocity into a voltage, so the quality of the electrode cable decides how clean that voltage arrives.

The same table gives a metric-length twin, 08712-0061-2003, for orders placed in metres. The two part numbers describe the same cable type; only the unit of length differs.

Cable rules stated in the datasheet

  • Remote transmitter installations need electrode and coil drive cables of equal length.
  • Individual cable lengths from 5 to 1000 ft (1.5 to 300 m) may be specified.
  • Cable longer than 100 ft (30 m) is not recommended for high-signal systems.
  • All cables are shipped with the sensor when ordered together.
  • Integrally mounted transmitters are factory wired and need no interconnecting cable.

These rules are taken from the ‘Cable requirements for remote transmitters’ block of the 8700 Series ordering section; the page does not add other claims.

Why equal lengths? The sensor electrodes produce a very small voltage, and the transmitter measures it against the reference created by the coil current. Matching the two cable lengths keeps the cable effects on the signal and drive paths in proportion, and the datasheet states the rule without exception for remote transmitters. In conductivity terms, the same document notes that the minimum conductivity of the process liquid, 50 microsiemens/cm for the 8707 high-signal sensor, excludes the effect of interconnecting cable length in remote installations, which is a reminder that long cables use up part of the signal margin.

Datasheet data for 08712-0061-0001

Parameter Value
Part number 08712-0061-0001
Description Electrode Cable (20 AWG), by the foot
Equivalent cable types Belden 8762, Alpha 2411
Metric version 08712-0061-2003
Conductor size 20 AWG
Specifiable length 5 to 1000 ft (1.5 to 300 m)
Used with 8712 remote transmitter, remote 8732 transmitter
Matching cable Coil drive cable 08712-0060-0001 (14 AWG)
Combination alternative 08732-0753-1003
Transmitter reference accuracy 0.25 percent of rate standard, 0.15 percent optional high accuracy

How 08712-0061-0001 differs from the coil drive and combination cables

Three cable products serve a remote magmeter. 08712-0061-0001 is the thin signal cable; 08712-0060-0001 is the heavy 14 AWG coil drive cable that powers the sensor coils; 08732-0753-1003 is a combination cable with a 20 AWG electrode pair and an 18 AWG coil drive in one jacket. A remote system using separate cables needs one of each and must keep them the same length. Choose the combination cable when a single run is wanted, up to the datasheet limit of 330 ft (100 m), and note that it is not recommended for high-signal systems.

System context: the 8700 Series

The 8700 Series pairs transmitters (8732 integral, 8712 remote HART, 8712H high-signal) with sensors (8705 flanged, 8707 high-signal, 8711 wafer, 8721 hygienic). The datasheet quotes standard reference accuracy of 0.25 percent of rate, with an optional 0.15 percent high accuracy calibration, and device diagnostics including Smart Meter Verification. The 8712 offers a 2 line by 20 character local operator interface and is suited to wall or pipe mounting, which is where the electrode cable run begins.

Selecting and installing the cable

Order 08712-0061-0001 in a length matching the sensor-to-transmitter distance and give the same length for the coil drive cable. Route the electrode cable away from power and motor cables, and keep it in its own conduit or gland path to the sensor junction box. Keep the shield terminations as shown in the sensor installation manual. For the sensor box, the datasheet notes that conduit entries must be sealed with IP68-approved cable glands when continuous submergence of up to 30 ft (10 m) is required.

The diagnostics that help to find a cable fault are listed in the datasheet. The basic set (empty pipe, electronics temperature, coil fault, transmitter faults and reverse flow) is available on the 8732 and 8712. Advanced Suite 1 (DA1 or D01) adds high process noise and grounding or wiring fault detection, which is the diagnostic most directly connected to a bad electrode cable or a poorly grounded sensor, and Suite 2 (DA2 or D02) adds Smart Meter Verification. They can be viewed through the local operator interface, a 475 Field Communicator or AMS Device Manager, so an electrode cable fault can often be located before anyone opens a junction box.

Maintenance and troubleshooting

Symptoms of a damaged electrode cable include noisy or zero readings, empty pipe alarms, and unstable output in a full pipe. Inspect the cable run for crushed jackets and moisture in junction boxes before replacing electronics. The datasheet’s diagnostics, including coil fault, grounding and wiring fault, high process noise and empty pipe, help to narrow the fault. Document the cable length and the date of installation in the instrument file.

Keep a note of the cable tag, the loop number of the flow transmitter and the sensor serial number together. The 8700 Series sensors are flow calibrated at the factory and carry a calibration number that the transmitter must store, so when a remote transmitter is replaced, the sensor calibration number should be re-entered or checked; the cable is not part of this, but a record of all three items speeds up troubleshooting after an outage.

Documents and quotation

The 8700 Series datasheet that carries the cable table for 08712-0061-0001 is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send your RFQ stating 08712-0061-0001, the length required in feet or metres, the transmitter type and the delivery location in Oman or the GCC.

Other Models in the Rosemount 8700 Remote Cables Range

Seven Star LLC supplies models from the Rosemount 8700 Remote Cables range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 08732-0753-1003 Combination Cable 20/18 AWGAutomation AccessoriesView details
Rosemount 08712-0060-0001 Coil Drive Cable 14 AWGAutomation AccessoriesView details
Rosemount 08712-0061-0001 Electrode Cable 20 AWGAutomation AccessoriesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Rosemount 08712-0061-0001 Electrode Cable 20 AWG Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 08712-0061-0001 Electrode Cable 20 AWG

Answers from our engineering team on installation, compatibility and integration.

01What is Rosemount 08712-0061-0001?
It is the 20 AWG electrode (signal) cable, equivalent to Belden 8762 or Alpha 2411, sold by the foot for remote Rosemount 8700 Series magmeters.
02Is there a metric version?
Yes. 08712-0061-2003 is the same cable type listed for ordering in metres.
03Must the cable lengths match?
Yes. The datasheet says remote transmitter installations require equal lengths of electrode and coil drive cables.
04What is the maximum length I can order?
Individual cable lengths from 5 to 1000 ft (1.5 to 300 m) may be specified, but over 100 ft (30 m) is not recommended for high-signal systems.
05Do integral transmitters need this cable?
No. Integrally mounted transmitters are factory wired and do not require interconnecting cables.