JUMO 707082/8-06 dTRANS T07 DIN Rail Temperature Transmitter

Description

JUMO 707082/8-06 DIN-rail version of the dTRANS T07

Where the head versions live in the field, JUMO 707082/8-06 lives in the cabinet. Base type 707082 is the dTRANS T07 T: a two-channel, HART 7 temperature transmitter packaged for a TH 35 DIN rail, with a green power LED, a red status LED and two 2 mm HART test sockets on its front. The suffix /8-06 means default configuration (0 to 100 C, Pt100 three-wire, 4 to 20 mA) and screw terminals. It carries neither Ex nor SIL approval, which makes it the plain, economical rail option of the series. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Typical reasons to buy this exact code are cabinet retrofits, replacement of a failed rail transmitter on a remote junction-box line, and projects that want a two-sensor measuring point without touching the sensor head.

Key data of 707082/8-06 at a glance

Measuring inputs Two independent inputs: RTD, thermocouple, resistance 10 to 400 or 10 to 2000 ohm, voltage -20 to 100 mV
RTD ranges Pt100 -200 to +850 C; Pt200 -200 to +850 C; Pt500 -200 to +500 C; Pt1000 -200 to +250 C; Ni100/Ni120 -60 to +250 C; Cu50/Cu100 -180 to +200 C
Output 4 to 20 mA or 20 to 4 mA, HART 7 (FSK 0.5 mA, 1200 baud)
Pt100 accuracy Typical 0.08 C digital, 0.1 C at current output (0.1 K class)
Galvanic isolation AC 2 kV input to output
Response time RTD 0.9 to 1.3 s; thermocouple 0.8 s
Sensor current 0.3 mA or less
Alarm levels 3.6 mA or less (low) or 21 mA or more (high, adjustable 21.5 to 23 mA); SIL mode low only
Approvals UL 61010-1 on all types
Supply DC 12 to 42 V (rail device)
Maximum burden (Ub max minus 12 V) divided by 0.023 A; 250 ohm minimum for HART
Ambient -40 to +85 C
Storage -40 to +100 C
Protection IP20
Climate class B2 per EN 60654-1; condensation not permitted
Vibration 2 to 100 Hz at 0.7 g
Weight About 100 g
Mounting TH 35 rail per DIN EN 60715, any orientation
Housing Polycarbonate, UL94 V-2
Terminals Screw, up to 2.5 mm2

Reading the front panel of 707082/8-06

The power LED shows green when the supply is healthy. The status LED stays off while no diagnostic message is active, lights solid red for a category F (failure) message and flashes red for category C, S or M messages. The two HART ports let a technician clip a communicator onto the front without opening the wiring, which is handy during commissioning. A fourth, internal service interface exists but is not intended for use.

What it measures

Each of the two inputs accepts Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Cu50, Cu100, Pt50 and polynomial RTDs, thermocouple types A, B, C, D, E, J, K, L, N, R, S, T and U, linear resistance (10 to 400 or 10 to 2000 ohm) and voltage from -20 to 100 mV. The inputs are not galvanically isolated from each other, and when both channels are used they must share a unit (both degrees C, F or K, or both ohm, or both mV). External cold junction can be set between -40 and +85 C, or the internal Pt100 junction used; thermocouple wire resistance up to 10 kilo-ohm is tolerated before a NAMUR NE89 fault is raised.

How 707082/8-06 differs from other dTRANS T07 variants

  • Versus 707080 (head): same electronics and approvals, but 707082 needs DC 12 V minimum instead of 11 V, is limited to IP20, and cannot sit in condensation.
  • Versus 707083 (rail with SIL): 707082 has no TUV SIL certificate, so it runs to +85 C ambient and can use the high alarm level.
  • Versus 707087 (rail with Ex): 707082 has no intrinsic-safety marking and must stay in the safe area.

The mechanical difference is also real: a rail unit weighs about 100 g against 40 to 50 g for a head unit, and uses the 4 g to 0.7 g lower vibration rating of general control-cabinet duty.

Commissioning 707082/8-06

Snap the unit on the rail, connect the 24 V loop supply and the 4 to 20 mA signal, and wire the sensors; the 24 V loop supply typically comes from a separate power supply unit. Use shielded cable once sensor lines exceed 30 m. After power-up allow roughly 10 s until HART answers and 28 s until the first valid current value; during this period the output stays at 3.8 mA or less. Then use a field communicator or PACTware with the JUMO DTM to set the sensor type, range, filter (0 to 120 s) and alarm level. Sensor-transmitter matching with Callendar-Van Dusen coefficients A, B and C is available for higher accuracy than the standard curve.

Applications for 707082/8-06 in GCC plants

Rail transmitters of this kind serve switchgear room monitoring, chilled-water and cooling-tower loops, compressor and pump bearing temperature collection, and cabinet-based skid control in utilities, water treatment and manufacturing. A two-channel input lets one unit watch an inlet and an outlet, report the difference, or back up a critical process sensor. Gulf ambient temperature inside an air-conditioned cabinet is well within the -40 to +85 C window.

Specified drift and accuracy are the same as for the other T07 types: typical 0.08 C digital for Pt100 and a maximum of 0.12 C over -200 to +850 C, plus operating influences of 0.02 C per degree ambient change for Pt100. Accessories listed by the manufacturer for the series include a USB HART modem (00443447), the mounting element for rail mounting of a B type (00352463) and a screwable DIN rail end holder (00528648).

Documents and quotation

The JUMO datasheet 707080 covering 707082/8-06 can be supplied with our quotation. Send the RFQ with the part number 707082/8-06, the quantity and any required range so we can confirm stock and delivery to Oman or elsewhere in the GCC.

What to Include in Your JUMO 707082/8-06 Enquiry

An accurate quotation for the JUMO 707082/8-06 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing temperature transmitters and reply with availability and a realistic delivery estimate.

Other Models in the DTRANS T07 Range

Seven Star LLC supplies models from the DTRANS T07 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
JUMO 707088/8-06 dTRANS T07 Ex SIL Rail TransmitterTemperature TransmittersView details
JUMO 707086/8-06 dTRANS T07 Ex SIL Head TransmitterTemperature TransmittersView details
JUMO 707082/8-06 dTRANS T07 DIN Rail Temperature TransmitterTemperature TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet JUMO 707082/8-06 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.

Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.

JUMO company profile

Established 1948, Fulda, Germany, by Moritz Kurt Juchheim
First products Glass and contact thermometers; platinum glass sensors from 1966
Ownership Family-owned; renamed JUMO GmbH & Co. KG in 2003
Product families RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments

Milestones

  • 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
  • 1966: Platinum glass temperature sensors are added.
  • 2003: The parent company is renamed JUMO GmbH & Co. KG.

JUMO products we list

Family Models Typical use
RTD and thermocouple probes 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp Temperature measurement in pipes, vessels, machines, HVAC and food plants
Thermowells and inserts 909710 thermowells, 909740 measuring inserts Protecting sensors and replacing them without opening the process
Temperature transmitters dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch Converting sensor signals to 4-20 mA, HART or IO-Link
Pressure and level dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 Pressure in process, hydraulic and OEM systems; tank and well level
Controllers, limiters and recorders DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T Furnace, oven and process control, over-temperature protection and recording
Liquid analysis and flow AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 pH, conductivity, oxygen and turbidity in water treatment; liquid flow

Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.

Where JUMO products are used

In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.

Ordering JUMO products: what we need

Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.

Facts checked against JUMO's company history, October 2026.

FAQ

Questions about the JUMO 707082/8-06 dTRANS T07 DIN Rail Temperature

Answers from our engineering team on installation, compatibility and integration.

01Is 707082/8-06 suitable for hazardous areas?
No. Type 707082 has no Ex approval; the Ex rail versions are 707087 and 707088.
02What supply voltage does 707082/8-06 need?
DC 12 to 42 V, which is one volt higher at the bottom than the head versions (DC 11 V).
03What do the LEDs on 707082/8-06 mean?
Green power LED means supply OK; the status LED is off for no message, solid red for category F and flashing red for categories C, S or M.
04What protection class has 707082/8-06?
IP20 on a TH 35 rail, so it belongs in a control cabinet or protected enclosure, and condensation is not allowed.
05Can 707082/8-06 measure thermocouples?
Yes, types A, B, C, D, E, J, K, L, N, R, S, T and U on either input, with internal or external cold junction.