Brand: Moore Industries
Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG] PROFIBUS PA Transmitter
Description
Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG] at a glance
Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG] brings a universal temperature input to a PROFIBUS PA segment. Instead of one analog pair per instrument, up to 32 devices (126 with repeaters) share a single twisted pair that also powers them. The BH2NG enclosure gives the unit an aluminum explosion-proof body, two 1/2-inch NPT entries and a glass cover for reading the local display.
Each TPZ order includes one copy of the Moore Intelligent PC Configuration Software, which means the transmitter can be set up from a laptop as well as from the host system.
PROFIBUS PA networks usually connect to a DP master through a DP/PA coupler, and the datasheet illustrates up to 32 TPZ devices behind such a coupler. The transmitter is then one of many slave addresses, and the two-digit address on its display helps technicians match a physical unit to the address in the engineering station.
What stands out on TPZ/TPRG/PA/9-32DC [BH2NG]
- PROFIBUS PA digital output, so the measurement arrives in engineering units with status, ready for a DP/PA coupler.
- Selectable sensor failure behaviour: a failsafe value, hold last valid value, or the PROFIBUS Wrong value that marks the instrument status as Bad.
- Damping from 1 to 30 seconds and an adjustable sensor trim offset.
- Identification data stored in the device: manufacturer, part number, serial number, tag, descriptor, revisions, installation date, slave address and identification number.
- A local display with a two-digit PROFIBUS address.
These features make it easy to bring a temperature point into a Siemens-style PROFIBUS system without an analog input card.
TPZ/TPRG/PA/9-32DC [BH2NG] data
The table below uses the TPZ datasheet.
| Parameter | Value for TPZ/TPRG/PA/9-32DC [BH2NG] |
|---|---|
| Model code | TPZ/TPRG/PA/9-32DC [BH2NG] |
| Protocol | PROFIBUS PA (IEC 61158-2, EN 50170 part 4 bus connection) |
| Segment capacity | Up to 32 devices per segment, 126 with repeaters |
| Input | TPRG: RTD, thermocouple J, K, E, T, R, S, B, N, C, millivolt, resistance, potentiometer |
| Supply | 9-32 V DC, 10.5 mA typical, 12.07 mA maximum, 18 mA under fault; 9-28 V for I.S. |
| Housing | BH2NG: aluminum explosion-proof BH, two 1/2-inch NPT entries, glass cover |
| Isolation | 500 Vrms between input, output and case; 500 Vac test for one minute |
| Step response | 500 ms maximum to availability of the processed variable |
| Input resolution | 20-bit |
| Display | 10 mm top row, 6 mm bottom row, two-digit PROFIBUS address |
| Weight | 235 g (8.33 oz) |
| Sensor failure mode | Selectable failsafe value, last valid value or PROFIBUS Wrong value (status Bad) |
| Damping | 1 to 30 seconds |
| Ambient temperature effect | Plus or minus 0.003% of maximum span per C |
| Start-up | Within specification 8 seconds after power |
| Configuration | Standard PROFIBUS PA tool such as Siemens SIMATIC PDM, or Moore PC Configuration Software |
Treat the supply row carefully: 9-32 V DC is the general window, while I.S. operation is quoted as 9-28 V in the datasheet. Also note that the ambient temperature effect is only 0.003% of the maximum span per degree C, a small figure that supports outdoor mounting in the high summer temperatures of the Gulf.
How TPZ/TPRG/PA/9-32DC [BH2NG] differs from TFZ and from the 4-20 mA transmitters
The TFZ is the FOUNDATION fieldbus sibling, and it shares the BH2NG form and the 9-32 V supply window; the TPZ differs in protocol, in its 235 g weight against 210 g for TFZ, and in the PROFIBUS address shown on the display. The step response is stated as 500 ms maximum for the TPZ, whereas the TFZ also lists a 256 ms typical figure.
Compared with the THZ or TDZ families, this code has no 4-20 mA output at all and cannot be moved to a conventional analog loop.
Applications
PROFIBUS PA is widespread in process plants with Siemens or compatible automation. The TPZ in BH2NG suits temperature monitoring of vessels, columns and utility lines in such plants, including chemical and water treatment facilities in the region.
Since 32 devices can share a segment, the cost saving over analog wiring grows with the number of temperature points.
The long-term stability of the TPZ is quoted as 0.008% of maximum span after one year for thermocouple and millivolt inputs and 0.047% for RTD, resistance and potentiometer inputs, rising to 0.019% and 0.104% after five years. These numbers help planners estimate how often a re-check of the measurement is justified.
Choosing TPZ/TPRG/PA/9-32DC [BH2NG]
Confirm the PA segment design: the DP/PA coupler, the segment power budget at 12.07 mA per device, and the cable length. If the plant needs intrinsic safety, the datasheet gives a 9-28 V supply range for I.S. use; the code you order must match the approval chosen.
If you intend to use another entry thread, the datasheet lists BH2TG for 3/4-inch NPT and BH2MG for M20.
Installing TPZ/TPRG/PA/9-32DC [BH2NG]
Mount the enclosure on the pipe, connect the sensor and segment, and configure the device address from the display, the host or the PC tool. Load the GSD or device description in the host, assign the tag and run the first reading.
Verify that a disconnected sensor produces the failure behaviour you selected.
Maintenance
Read the device diagnostics from the host and confirm that the status is Good in normal operation. Clean the glass and inspect the seals at inspection rounds. The long-term stability allows multi-year calibration intervals.
Keep a copy of the device configuration with the loop file.
Prepare the host project before the field work: import the device description, create the slave address plan, and reserve the identification number mapping. When the transmitter arrives on site it can then be addressed, tagged and brought online in a few minutes.
Supply of TPZ/TPRG/PA/9-32DC [BH2NG]
Please quote TPZ/TPRG/PA/9-32DC [BH2NG] in full in your enquiry and state the host system.
Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.
Documents and quotation
We can attach the datasheet for Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG] to our quotation. Send an RFQ with the part number, quantity and delivery location.
Datasheets & Documents
- Datasheet Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG] PROFIBUS PA Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries TPZ/TPRG/PA/9-32DC [BH2NG]
Answers from our engineering team on installation, compatibility and integration.
01What protocol does the TPZ use?
PROFIBUS PA with a bus connection according to IEC 61158-2 and EN 50170 part 4.
02How many devices fit on a segment?
The datasheet allows up to 32 devices per segment, or up to 126 when repeaters are used.
03What happens when the sensor fails?
You can select a failsafe value, hold the last valid value, or output the PROFIBUS Wrong value that signals Bad status.
04What software comes with the TPZ?
Each order includes one copy of the Moore Intelligent PC Configuration Software.
05How much does it weigh?
The datasheet lists 235 g (8.33 oz) for the TPZ in its standard form.