Böhler FOXcore 2209-T1 E2209T1-4 Duplex Flux-Cored Wire

Description

Rutile duplex flux-cored wire for 22Cr steels in offshore and chemical plant

The Böhler FOXcore 2209-T1 is a rutile duplex stainless flux-cored wire of type T 22 9 3 N L P / E2209T1, classified AWS A5.22 E2209T1-4(1). Böhler Welding specifies it for 22Cr steel grades such as 1.4462 (UNS S31803 and S32205), and for dissimilar joints and weld cladding, designed for offshore, shipyards, chemical tankers, chemical and petrochemical plants and pulp and paper. It has very good resistance to pitting, intergranular and stress corrosion cracking in chloride-containing environments such as seawater, and meets ASTM G48 Methods A, B and E at 77 °F. It is over-alloyed in nickel to promote austenite formation, and ferrite measured with a Fischer Feritescope is 35 to 45 FN. The wire is used in all positions without changing parameters.

Technical specifications

Parameter Specification
AWS classification A5.22 / SFA-5.22 E2209T1-4(1)
EN ISO 17633-A / -B T 22 9 3 N L P M21 (C1) 1 / TS 2209-F M21 (C1) 1
Typical analysis, wt % C 0.026; Si 0.6; Mn 1.1; Cr 23.0; Ni 9.0; Mo 3.2; N 0.14; PREN 35 or higher; FN 40 to 60
Yield strength Rp0.2, as welded 87 ksi typical (minimum 65)
Tensile strength Rm, as welded 116 ksi typical (minimum 100)
Elongation A (L0=5d0) 27 % typical (minimum 20)
Impact energy ISO-V 43 J at 68 °F; 33 J at -50 °F (minimum 24)
Hardness 260 HB
Service temperature -50 °F to 482 °F
Diameter 0.045 in
Gas and polarity Ar plus 15 to 25 % CO2; 100 % CO2 with 2 V more (austenite content rises somewhat); gas flow 16 to 20 l/min; DC+
Heat input and interpass 0.5 to 1.5 kJ/mm; interpass maximum 302 °F; stick-out 15 to 20 mm
Approvals TÜV (07666), ABS, BV (C1 and 1.2 mm), CCS (C1 and 1.2 mm), CWB, DNV GL, LR, RINA (M21), CE

Using duplex cored wire correctly

The data sheet advises a backhand (drag) technique with a work angle around 80 degrees on a standard GMAW source with no pulsing, and no post-weld heat treatment except in special cases (solution annealing at 2012 to 2165 °F with water quench). For flat and horizontal positions (1G, 1F and 2F) Böhler suggests FOXcore 2209-T0 instead. Observe the heat-input window, as too little heat input leaves too much ferrite and too much heat input reduces ferrite and toughness. The wire is the cored-wire member of a duplex set that includes the

Thermanit 22/09.

TIG rod and the

FOX CN 22/9 N-B.

electrode.

Related Böhler Welding cored wire Classification Typical use
FOXcore 71 RC AWS A5.20 E71T-1 family All-position rutile wire for mild steel, 0.045 to 1/16 in.
FOXcore 316L-T1 AWS A5.22 E316LT1-4(1) 316L stainless, all positions
FOXcore 309L-T1 AWS A5.22 E309LT1-4(1) Buffer layers and dissimilar joints

Handling and what to confirm

Confirm base grade, plate thickness, ferrite and corrosion-test requirements (ASTM G48 or A923), shielding gas, spool format and class approvals. Only the 0.045 in diameter is on the data sheet, so if another diameter is needed ask before ordering.

How the Böhler FOXcore 2209-T1 works

The FOXcore 2209-T1 is a tubular wire with a rutile flux core inside a stainless steel sheath. In the arc the core forms a slag that supports the weld pool, gives a smooth bead and lets the wire run in all positions with one set of parameters. The weld metal is a duplex alloy of about 22 percent chromium, 9 percent nickel, 3 percent molybdenum and added nitrogen. Nickel is set above the level of the parent steel so that, as the weld cools, enough austenite forms next to the ferrite. That balance gives the joint its strength and its resistance to pitting and stress corrosion cracking.

Where the FOXcore 2209-T1 is used

  • Fabrication of duplex 22Cr piping, vessels and tanks for chemical and petrochemical plants
  • Offshore topside piping and structures exposed to seawater
  • Chemical tankers and shipyard work on duplex cargo systems
  • Pulp and paper equipment in chloride-bearing service
  • Dissimilar joints between duplex steel and carbon or low-alloy steel
  • Weld cladding of carbon steel surfaces

Selection checklist for the FOXcore 2209-T1

  • Parent steel grade, for example 1.4462 (UNS S31803 or S32205)
  • Welding positions needed, and whether flat and horizontal work could use the T0 type instead
  • Shielding gas available on site, and the gas flow range
  • Wire diameter, 0.045 in on this page, and the feeder and liner fitted to the machine
  • Approvals required by the project, such as ABS, BV, DNV GL, LR or RINA
  • Minimum design temperature, since the listed service range is -50 to 482 degrees F
  • Procedure qualification requirements for impact toughness and ferrite content

Installation, commissioning and maintenance notes

Duplex welding is controlled by the procedure, so the welding procedure should be qualified on the actual steel and joint before production starts. Keep the wire in its sealed packaging until use, and store it dry. Check the polarity, the gas flow and the stick-out against the data sheet at the start of each shift. Watch the heat input and the interpass temperature on every pass, and clean slag fully between passes. Record the batch number of the wire against the weld map so that the joint can be traced.

Requesting a quotation for the Böhler FOXcore 2209-T1

Please send the parent steel grade, the joint type and the positions, the wire diameter and the quantity. State the approvals and the shielding gas that the project requires. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

Shielding gas for FOXcore 2209-T1

The data sheet lists argon with 15 to 25 percent carbon dioxide at 16 to 20 litres per minute. Pure carbon dioxide can be used with about 2 volts more, but the austenite content then rises somewhat, so the ferrite result should be checked on the procedure test.

Ferrite control

Ferrite is measured with a Fischer Feritescope and is stated as 35 to 45 FN on this page. Too little heat input leaves too much ferrite, and too much heat input can lower it. Welders should keep to the heat input window of 0.5 to 1.5 kJ/mm.

Weld positions and technique

The wire is used in all positions without changing parameters. Use the backhand drag technique with a work angle of about 80 degrees, and do not pulse the power source.

Post-weld treatment

No post-weld heat treatment is normally needed. In special cases the data sheet describes solution annealing at 2012 to 2165 degrees F followed by a water quench.

Weld records for FOXcore 2209-T1

Keep the wire batch, the parameters, the interpass temperatures and the ferrite readings with the weld file. These records support the inspection and the project documentation.

Documents and quotation

This listing includes the Böhler Welding data sheet for FOXcore 2209-T1. See flux-cored welding wire for related consumables. For an offer please give the dimensions, packaging, quantity, material to be welded and the inspection certificate type.

Datasheets & Documents
  • PDF Datasheet Böhler Welding FOXcore 2209-T1 product data sheet (US edition) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Böhler Welding is the welding consumables and equipment brand of voestalpine Böhler Welding, part of the Austrian steel and technology group voestalpine. Its roots go back to 1870, when the brothers Albert and Emil Böhler founded the Böhler company in Vienna; in 1894 they bought the steel works in Kapfenberg, Styria, which became the home of Böhler special steels and, later, Böhler welding filler metals. Welding became a separate division of the newly formed Böhler-Uddeholm group in 1991. voestalpine took over Böhler-Uddeholm in 2007, and the welding business, headquartered in Düsseldorf, Germany, has been part of voestalpine's Metal Engineering Division since 2013.

Böhler Welding company profile

Origins 1870, Vienna, Austria: Albert and Emil Böhler found the Böhler company; Kapfenberg steel works acquired in 1894
Welding business Separate division of Böhler-Uddeholm from 1991 (the same year it acquired UTP)
Ownership voestalpine AG (Linz, Austria), which took over Böhler-Uddeholm in 2007; welding integrated into the Metal Engineering Division in 2013
Headquarters Düsseldorf, Germany (voestalpine Böhler Welding); Austrian company seated in Kapfenberg
Brands in the group Böhler Welding (joining consumables and welding machines), UTP Maintenance (repair and hardfacing), Fontargen Brazing; product lines such as FOX, Thermanit, Union, diamondspark, FOXcore, Marathon and UV fluxes
Product families Stick electrodes, TIG rods, MIG/MAG solid wires, flux-cored and metal-cored wires, submerged arc wires and fluxes, welding machines and plasma cutters

Milestones

  • 1870: Albert and Emil Böhler found the company in Vienna.
  • 1894: The Kapfenberg cast steel works is purchased.
  • 1991: Böhler Welding becomes a separate division of Böhler-Uddeholm and acquires UTP.
  • 2007: voestalpine makes its takeover offer for Böhler-Uddeholm.
  • 2013: The welding business is integrated into voestalpine's Metal Engineering Division as voestalpine Böhler Welding.

Choosing Böhler welding consumables

The filler metal must match the base metal and the service. Carbon steel pipe is often welded with a cellulosic root (FOX CEL+, AWS E6010) because it penetrates well in vertical-down welding, followed by low-hydrogen fill and cap passes (FOX EV 50, E7018-1, or FOX BVD vertical-down electrodes). Creep-resistant chromium-molybdenum steels need matching consumables and controlled preheat and post-weld heat treatment: for example FOX DCMS Kb (E8018-B2) for 1.25Cr-0.5Mo, FOX CM 2 Kb (E9018-B3) for 2.25Cr-1Mo and Thermanit Chromo 9 V Mod for P91. Duplex stainless steel uses an over-alloyed 2209 filler (FOX CN 22/9 N-B, Thermanit 22/09) to keep the ferrite-austenite balance. Low-hydrogen electrodes must be stored dry and re-baked according to the data sheet.

Where Böhler Welding products are used

In Oman and the GCC, Böhler consumables are used on cross-country pipelines, oil and gas facilities, refineries and petrochemical plants, power and desalination plants with P91 and Cr-Mo piping, pressure vessel and tank fabrication, and structural steel work.

Böhler Welding products we list

Family Examples
Stick electrodes FOX CEL+ E6010, FOX EV 50, FOX EV PIPE, FOX BVD 85, FOX DCMS Kb, FOX CM 2 Kb, FOX CN 22/9 N-B, Thermanit Chromo 9 V Mod
TIG rods EMK 6, Union ER 80S-B2, Union ER 90S-B3, Thermanit GE-316L, Thermanit 22/09, Thermanit 309L
Flux-cored and metal-cored wires FOXcore 71 RC, diamondspark 52 RC, diamondspark X70 RC-Pipe, FOXcore 316L-T1, FOXcore 2209-T1
Submerged arc wires and fluxes Union S 2 Si, Union S 3 Si, Union S 1 CrMo 2, Thermanit MTS 3 LNi, UV 418 TT, Marathon 543
Welding and cutting machines TERRA 500 RC, TERRA NX 400 TLH, TERRA NX 500 PME, SABER 70 CHP

Ordering Böhler Welding products: what we need

Send the product name and AWS or EN classification (for example FOX EV 50, AWS A5.1 E7018-1), the diameter and the quantity in kg. For project work, tell us the base material, welding process and any certificate needed, such as an EN 10204 3.1 inspection certificate.

Facts checked against voestalpine's published company histories, October 2026.

FAQ

Questions about the Böhler FOXcore 2209-T1 E2209T1-4 Duplex Flux-Cored

Answers from our engineering team on installation, compatibility and integration.

01What is the classification of FOXcore 2209-T1?
AWS A5.22 E2209T1-4(1) and EN ISO 17633-A T 22 9 3 N L P M21 (C1) 1.
02What ferrite level is stated?
35 to 45 FN measured with a Fischer Feritescope; typical analysis lists 40 to 60 FN.
03Which service temperatures are given?
-50 °F to 482 °F.
04Which diameter is listed?
0.045 inch.
05Which approvals are printed?
TÜV (07666), ABS, BV, CCS, CWB, DNV GL, LR, RINA and CE.