Honeywell STG78S SmartLine STG700 Gauge Pressure Transmitter
Description
STG78S at a glance
The Honeywell STG78S is the first of the two very-high-pressure gauge models in the STG700 SmartLine line, with a URL of 6,000 psi (420 bar). It is aimed at hydraulic test stands, high-pressure injection and gas-lift systems where standard 3,000 psi devices are no longer enough.
Its minimum span is 60 psi (4.2 bar), maximum turndown 100:1, and its MAWP equals the upper limit at 6,000 psi (420 bar). For devices rated above 2,000 psi MAWP the datasheet defines the minimum no-burst pressure as 2.5 times MAWP plus 1,000 psi, so the STG78S is rated against a no-burst threshold of 16,000 psi.
What stands out on the STG78S
- URL 6,000 psi (420 bar) and LRL minus 14.7 psi (minus 1.0 bar).
- Reference turndown 10:1, knee C of 600 psi (42 bar).
- Temperature effect 0.100 plus 0.070 times URL over span per 28 degC.
- Total performance 0.455 percent of span at 1,200 psi, 5:1 turndown.
- HART 7 with 4 to 20 mA output and NAMUR NE 43 failure levels available.
STG78S specification table
| Parameter | Value |
|---|---|
| Model | STG78S (STG700 SmartLine gauge pressure) |
| Upper range limit | 6000 psi (420 bar) |
| Lower range limit | -14.7 psi (-1.0 bar) |
| Minimum span | 60 psi (4.2 bar) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.065 percent of span (A 0.005, B 0.060) |
| Accuracy knee C | 600 psi (42 bar) |
| Temperature effect | 0.100 + 0.070 x URL/span, percent of span per 28 degC |
| Total performance example | 0.455 percent of span at 1200 psi |
| Stability | 0.020 percent of URL per year, quoted over ten years |
| MAWP | 6000 psi (420 bar) |
| Output / protocol | Two-wire 4 to 20 mA with HART 7 |
| Supply voltage and loop load | 10.8 to 42.4 VDC at the terminals (intrinsically safe versions limited to 30 VDC); load 0 to 1,440 ohms |
| Response time | 100 ms; turn-on time 2.5 s; damping 0 to 32 s, default 0.5 s |
| Rated ambient / meter body temperature | -40 to 85 degC / -40 to 110 degC (operative limit 125 degC) |
| Overpressure | 1.5 x MAWP of the model |
| Process connections | Dual head: 1/2-inch NPT female. Inline: 1/2-inch NPT female or male, 9/16-18 high-pressure cone and thread female, G1/2-B male |
| Wetted diaphragm / head | 316L stainless steel or Hastelloy C-276 diaphragm; heads in carbon steel (zinc plated), 316 SS or Hastelloy C-276 (dual head), 316L SS or Hastelloy C-276 (inline) |
| Fill fluid | Silicone or CTFE |
| Housing | Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional |
| Net weight | Dual head 8.3 lb (3.8 kg); inline 3.6 lb (1.6 kg), with aluminium housing |
STG78S compared with the rest of the STG700 line
The STG78S differs from the STG77S (3,000 psi) by doubling the range, and from the STG79S (10,000 psi) by its lower temperature coefficient: 0.100 plus 0.070 versus 0.200 plus 0.170. As a result the STG78S shows 0.455 percent total performance at 1,200 psi, whereas the STG79S shows 1.052 percent at 2,000 psi.
Minimum span is 60 psi (4.2 bar), compared with 100 psi (6.9 bar) for the STG79S and 30 psi (2.1 bar) for the STG775 and STG77S.
| Model | URL | Min span | Knee C | Temp D + E |
|---|---|---|---|---|
| STG775 / STG77S | 3000 psi | 30 psi | 350 / 400 psi | 0.075+0.013 / 0.100+0.025 |
| STG78S | 6000 psi (420 bar) | 60 psi (4.2 bar) | 600 psi (42 bar) | 0.100 + 0.070 |
| STG79S | 10000 psi | 100 psi | 1200 psi | 0.200 + 0.170 |
Process situations suited to STG78S
In Oman the STG78S suits wellhead chemical injection at high pressure, gas lift manifolds, hydrotest pump skids for pipeline commissioning and intensifier systems. In manufacturing it serves waterjet cutting pumps and isostatic presses.
Because the temperature effect grows rapidly with span ratio, it works best when the calibrated span is at least a few hundred psi.
Fitting STG78S into an existing instrument list
Confirm that the connection is a high-pressure type. The inline version offers 9/16-18 cone and thread female, which is the standard high-pressure fitting; confirm the fitting designation of the mating tubing before ordering. For the dual head body, the process connection is 1/2-inch NPT female.
At this pressure ask for a hydrostatic certification route if your inspection rules demand one, as the datasheet notes that CRN approval units need factory consultation.
Piping up and starting STG78S
Use proper high-pressure fittings and anti-blowout restraints where specifications call for them. Pressurise slowly, check each joint for leaks, and keep the housing rotated so that the display is readable and the conduit entry faces downward to drain moisture.
Adjust damping if the plunger pump produces pulsation; the setting range is 0 to 32 seconds.
Care, checks and spare modules
Verify every two years. Inspect high-pressure connections for fretting or thread damage and replace seals when the fitting is removed. Store spare meter bodies in a dry area.
STG78S: practical questions answered
What is the range of the Honeywell STG78S? It spans minus 14.7 psi to 6,000 psi (minus 1.0 to 420 bar), with a minimum span of 60 psi (4.2 bar).
What is the MAWP of the STG78S? The maximum allowable working pressure equals the upper range limit, 6,000 psi (420 bar).
What temperature effect does the STG78S have? The datasheet gives 0.100 plus 0.070 times URL over span, expressed as percent of span per 28 degC shift.
What is the STG78S total performance? The datasheet example gives 0.455 percent of span at 1,200 psi with 5:1 turndown and a 28 degC shift.
How is the STG78S different from the STG79S? The STG79S reaches 10,000 psi (690 bar) with a 100 psi minimum span but has larger temperature coefficients.
Documents and quotation
The STG700 datasheet covers the STG78S in full detail.
To request a quote for Honeywell STG78S, send part number, quantity, range and connection type to Seven Star LLC.
Selection Notes for the Honeywell STG78S
When comparing the Honeywell STG78S with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Honeywell pressure transmitters range and confirm the correct order code before you commit.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Honeywell STG78S, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Honeywell pressure transmitters items can be checked against the bill of materials quickly.
Other Models in the STG700 Range
Seven Star LLC supplies models from the STG700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STG735 SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STG745 SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STG775 SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STG73S SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STG78S SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | You are viewing this model |
| Honeywell STG79S SmartLine STG700 Gauge Pressure Transmitter | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Honeywell STG78S SmartLine STG700 Gauge Pressure Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STG78S SmartLine STG700 Gauge Pressure
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STG78S?
It spans minus 14.7 psi to 6,000 psi (minus 1.0 to 420 bar), with a minimum span of 60 psi (4.2 bar).
02What is the MAWP of the STG78S?
The maximum allowable working pressure equals the upper range limit, 6,000 psi (420 bar).
03What temperature effect does the STG78S have?
The datasheet gives 0.100 plus 0.070 times URL over span, expressed as percent of span per 28 degC shift.
04What is the STG78S total performance?
The datasheet example gives 0.455 percent of span at 1,200 psi with 5:1 turndown and a 28 degC shift.
05How is the STG78S different from the STG79S?
The STG79S reaches 10,000 psi (690 bar) with a 100 psi minimum span but has larger temperature coefficients.