Honeywell CC-PUIO31 Series C Universal I/O Module 32-Channel
Description
Honeywell CC-PUIO31 Series C universal I/O module overview
Honeywell CC-PUIO31 is the 32-channel Universal Input Output module in the Experion Series C family, designed to sit in a C300 control cabinet and talk to whatever field device the project throws at it. Every one of its 32 channels can be set in configuration as an analog input, an analog output, a digital input or a digital output, and any four channels can serve as pulse inputs. In practice that means a single module can replace what used to be three or four dedicated I/O cards, which matters when cabinet space or the spare-parts shelf is limited. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; this page summarises the manufacturer’s Series C I/O specification so that maintenance and procurement teams can confirm the module before sending an RFQ.
The module is described in the Series C I/O Specification, document EP03-490-520, which went through revisions that specifically touched this part: a Digital Output update in September 2020 and an electronic short circuit protection update in December 2021. Those revision notes are a useful hint when you compare an older module on the shelf with a newly supplied one, because the channel behaviour described for the module has been refined over time.
Key features of CC-PUIO31
- Per-channel personality: analog input, analog output, digital input (including sequence of events) or digital output, selected in software rather than by hardware jumpers.
- 32 channels per module, with open wire detection available on the analog and digital channel types.
- HART 7 support on the analog channels, with a dedicated HART modem per channel for fast performance.
- Electronic short circuit protection: a field short on one signal does not damage the module or its termination assembly and does not disturb the other channels.
- Fast Scan priority module scan for loops that cannot wait for the normal scan cycle.
- Configurable safe-state (FAILOPT) behaviour per channel for digital and analog outputs.
- Module ambient temperature range of -40 to +70 degrees C.
CC-PUIO31 technical specifications
| Parameter | Value |
|---|---|
| Module model | CC-PUIO31 |
| Function | Universal Input Output, 32 channels per module |
| Channel types | AI, AO, DI (with SOE option), DO, pulse input on any four channels |
| IOTA, non-redundant | CC-TUIO31, 9 inch |
| IOTA, redundant | CC-TUIO41, 12 inch |
| AI type and range | Current, 2, 3 or 4 wire devices; 0-20 mA or 4-20 mA |
| AI resolution / scan | 16 bit A/D; 10 ms input scan rate |
| AI hardware accuracy | 0.1% of full scale at 23.5 plus or minus 2 C; 0.175% from 0 to +70 C; 0.25% from -40 to +70 C |
| AI input impedance | 250 ohm; filter single pole, -3 dB at 6 Hz |
| AI overvoltage tolerance | +33 VDC to -1 VDC, no damage |
| Pulse input | 0-15 kHz, minimum pulse width 25 microseconds |
| AO output | 4-20 mA with HART; 12 bit resolution; settable range 0 mA and 2.9 to 21.1 mA |
| AO load | Maximum resistive load 825 ohm at 20 mA; compliance 16.5 VDC at 20 mA |
| AO response | 80 ms in HART mode, 0.25 ms in non-HART mode |
| DI thresholds, no OWD | Closed above 3.2 mA, open below 2.0 mA, 7 mA maximum closed current |
| DI SOE resolution | 1 ms on any or all channels |
| DO type | Solid state source, short circuit protected; 1 mA minimum to 0.5 A maximum per channel; 9 A maximum per module |
| DO on-state voltage | 24 V typical at 0.5 A load |
All numbers above come from the Series C I/O specification. The module interfaces with the C300 controller through the IOTA, which also carries the field terminals, so the wiring stays on the termination assembly when the electronics module is swapped.
How CC-PUIO31 differs from other Universal I/O variants
The family also contains CC-PUIO01 on 12 inch (CC-TUIO01) and 18 inch (CC-TUIO11) termination assemblies. The two modules look similar on a drawing but differ in measurable ways, and mixing up their specifications causes loop-check surprises.
| Parameter | Value |
|---|---|
| Parameter | CC-PUIO31 versus CC-PUIO01 |
| IOTA size | 9 inch / 12 inch redundant, versus 12 inch / 18 inch |
| Pulse inputs | Any four channels, 0-15 kHz, 25 microsecond minimum, versus channels 15 to 18 only, 0-10 kHz, 50 microsecond minimum |
| AI scan rate | 10 ms, versus 50 ms |
| AI normal mode filter | Single pole -3 dB at 6 Hz, versus -3 dB at 16 Hz |
| AO settable range | 0 mA and 2.9 to 21.1 mA, versus 0 to 23 mA |
| AO maximum load | 825 ohm at 20 mA, versus 700 ohm |
| AO response | 80 ms HART / 0.25 ms non-HART, versus 2 ms |
| DI sequence of events | Supported with 1 ms resolution, listed only on this variant |
Typical applications for CC-PUIO31 in Oman and the GCC
A universal channel is most valuable where the final I/O count is uncertain until late in a project, or where a brownfield DCS expansion has to reuse limited cabinet space. In oil and gas gathering stations the module can take 4-20 mA transmitter signals, drive control valve positioners over HART and monitor on-off valve limit switches from the same card. In power and utility plants the sequence of events option on digital input channels, at 1 ms resolution, helps reconstruct a breaker or turbine trip chain. Water and desalination sites use the pulse input for flow meters, and manufacturing plants appreciate that a spare module can be moved between racks and configured for whichever channel mix the failed card carried.
Selection and compatibility notes for CC-PUIO31
Confirm three things before ordering. First, the termination assembly: CC-TUIO31 is the 9 inch non-redundant IOTA, and CC-TUIO41 is the 12 inch redundant version where a second module is plugged on for hot standby. Second, the channel mix: the specification notes that channel usage depends on operating temperature and refers to the user’s guide for the calculation, so a fully loaded module in a hot cabinet should be checked rather than assumed. Third, the field wiring: AI, AO and DI channels are certified to support energy limited or non-incendive field wiring into Zone 2 or Division 2 locations, which is not the same as intrinsic safety, so Zone 1 signals still need barriers.
A digital output channel driving a very light load deserves a special look. The manufacturer notes that a channel configured for digital output can report a line monitoring or output fail condition if the load current is below 20 mA, so lamp-sized or relay-sized loads should be tested during loop checks.
Installing and commissioning CC-PUIO31
Mount the IOTA in the cabinet first, land the field cables on its detachable two-level terminals and only then plug the module on. Because Series C modules are tilted for convection cooling, keep the space above and below each IOTA clear as described in the platform documentation. During commissioning, set the channel types in Control Builder, tune the FAILOPT safe-state behaviour for each output, and run HART discovery on the analog loops. Test the open wire detection by lifting a field wire; for digital inputs with the detection function, remember that the field resistor arrangement in the user’s guide must match the thresholds, which are 0.9 mA to 2.0 mA for the open contact state on this module.
Maintenance and spares planning for CC-PUIO31
The short circuit protection removes the need for in-line fusing, so most field faults show up as channel status rather than as a blown fuse. Keep a spare module and note the revision. Because the module plugs onto its IOTA and takes power from it, replacement does not disturb field wiring. After a swap, check that the configured channel personality loaded correctly and that HART devices answer. For redundant pairs, the specification states a 0 ms output gap at switchover, so a standby module can be exchanged without a process bump when the partner is healthy.
Frequently asked points about CC-PUIO31
Buyers often ask whether the module can mix input and output channels (yes, per channel), whether it supports HART (yes, version 7 on analog channels) and which IOTA is needed (CC-TUIO31 or CC-TUIO41). The questions below expand on the ones that most affect ordering.
Documents and quotation
The Series C I/O specification covering CC-PUIO31 is attached to this page as a datasheet download. When you request a quotation, please send the part number CC-PUIO31, the quantity, the matching IOTA model if you need it, and your delivery location in Oman or the GCC. Our team will reply with availability and lead time. Honeywell is a registered trademark of its owner and is used only to identify compatibility.
Datasheets & Documents
- Datasheet Honeywell CC-PUIO31 Series C I/O Specification Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell CC-PUIO31 Series C Universal I/O Module
Answers from our engineering team on installation, compatibility and integration.
01What can each channel of Honeywell CC-PUIO31 be configured as?
Each of the 32 channels can be configured as an analog input, analog output, digital input or digital output, and any four channels can be used as pulse inputs, according to the Series C I/O specification.
02Which termination assemblies does CC-PUIO31 plug onto?
The non-redundant 9 inch CC-TUIO31 and the redundant 12 inch CC-TUIO41, per the specification's model table.
03How does CC-PUIO31 differ from CC-PUIO01 on pulse inputs?
On CC-PUIO31 any four channels can be pulse inputs up to 15 kHz with a 25 microsecond minimum pulse; CC-PUIO01 restricts pulse inputs to channels 15 to 18 at up to 10 kHz and 50 microseconds.
04What analog output range is settable on CC-PUIO31?
The directly settable output current range is 0 mA and 2.9 mA to 21.1 mA, with a maximum resistive load of 825 ohms at 20 mA.
05How do I request CC-PUIO31 from Seven Star LLC?
Send the part number CC-PUIO31, quantity, the IOTA model needed and your delivery location, and we will respond with availability. Seven Star LLC is an independent supplier.