EVRA 25: a flanged servo-piston solenoid valve for ammonia and industrial refrigerants

The 032F6226 is an EVRA 25, a normally closed solenoid valve with flange connections for industrial refrigeration. The product page lists a cast iron body, a servo-piston operation, a 25 mm orifice, a Kv value of 10 m3/h and a net weight of 3.031 kg. It is supplied without a coil, and flanges are a separate accessory.

The maximum working pressure is 42 bar (610 psig) and the medium temperature range is -40 to 105 C, with a note that defrost can reach 130 C (265 F) at most. The minimum opening differential is 0.2 bar (2.9 psi), and the MaxOPD depends on the coil: 21 bar with 10 W AC, 25 bar with 12 W AC and 14 bar with 20 W DC.

Technical specifications

Parameter Specification
Danfoss code number 032F6226
Type EVRA 25
Ambient temperature -40 – 80 C
Approvals as listed C UL US LISTED; EAC; UA
Body material Cast iron
Function NC
Inlet connection type Flange
Kv value 10 m3/h
Maximum working pressure 42 bar
MaxOPD 10W AC 21 bar
MaxOPD 12W AC 25 bar
MaxOPD 20W DC 14 bar
Medium temp. range note Defrost max 130 C/265 F
Medium temperature range -40 C to 105 C
MinODP 0.2 bar
Orifice size 25 mm
Outlet connection type Flange
Refrigerants R134a; R22; R401A; R402A; R404A; R407A; R407B; R407C; R407F; R409A; and others listed in the data sheet
Type designation Solenoid valve
Valve operation Servo-piston
Net weight 3.031 kg
EAN 5702422180371

Why the EVRA differs from the EVR

The EVRA series is the version of the solenoid valve made for ammonia (R717) and other industrial refrigerants, with materials suited to them, whereas the EVR is for fluorinated refrigerants. The flanged ends allow the valve to be bolted into steel pipework without welding the body, which makes inspection and replacement easier.

Typical uses are liquid-line shut-off, hot-gas defrost supply and suction-line stop duty in cold stores and process plants. UL (C UL US Listed), EAC and UA approvals are shown on the product page.

Flanges, coils and ordering

Order matching flanges and a coil that suits the supply: the MaxOPD changes strongly with coil power. The catalogue and the data sheet for EVRA also list spare parts and accessories as a separate document. Install the coil upward and keep the line free from welding debris.

Confirm that the refrigerant is within the approved list, the flange standard and the working pressure class. Because the opening needs a minimum differential, check low-load conditions on suction duty before choosing this code.

Other types and sizes from the same Danfoss family that appear in the Danfoss store listing include EVRA 3 (032F3050), EVRA 3.5 (032F3138), EVRA 32 (042H1126), EVRA 40 (042H1128). These are listed for orientation only; each has its own datasheet values, so check size, connection and version before ordering.

Related Danfoss products: Danfoss 032U7132 EV220B 32 Solenoid Valve G 1 1/4 NC, Danfoss 032L1188 EVR 10 Solenoid Valve 1/2 in Solder NC, Danfoss 032U3806 EV225B 20 Steam Solenoid Valve G 3/4 NC, Danfoss 032U5254 EV250B 18 Solenoid Valve G 3/4 NC 0 bar, Danfoss 032U7115 EV220B 15 Solenoid Valve G 1/2 NC EPDM and Danfoss 032U7150 EV220B 50 Solenoid Valve G 2 NC 40 m3/h.

Documents and quotation

The attached file is the Danfoss Solenoid valve, type EVRA AI221486430911en-001201 (manufacturer, unaltered). It is the manufacturer’s own PDF, hosted here unaltered. Related items sit under solenoid valves. Seven Star LLC is an independent supplier in Muscat; send the code 032F6226 with the quantity and we will quote.

Datasheets & Documents
  • PDF Datasheet Danfoss Solenoid valve, type EVRA AI221486430911en-001201 (manufacturer, unaltered) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 032F6226 EVRA 25 Solenoid Valve, Flanged, NC

Answers from our engineering team on installation, compatibility and integration.

01What is Danfoss 032F6226?
An EVRA 25 normally closed flanged solenoid valve, cast iron, 25 mm orifice, for industrial refrigeration.
02What is the Kv value?
10 m3/h.
03What is the maximum working pressure?
42 bar (610 psig).
04Is the coil included?
No. The coil and flanges are ordered separately.
05Which document is attached?
The Danfoss EVRA solenoid valve data sheet AI221486430911en-001201.