DUNGS logo

DUNGS

Open the gas train cabinet of a boiler or an industrial burner and there is a good chance the valves and pressure switches inside are marked DUNGS. Karl Dungs was founded in 1945 and is based in Urbach, Germany, and it makes gas valves and combustion controls for heating, process heat and gas engines. Seven Star LLC sources and supplies DUNGS gas valves, regulators, pressure switches and valve proving systems for burner operators in Oman, identified by type designation and article number.
Read more about DUNGS

Brand profile

About DUNGS

All brands →
Founded
1945
Headquarters
Urbach, Germany
Speciality
Gas valves and combustion controls
Listed with us
9 products in 4 categories

Open the gas train cabinet of a boiler or an industrial burner and there is a good chance the valves and pressure switches inside are marked DUNGS. Karl Dungs was founded in 1945 and is based in Urbach, Germany, and it makes gas valves and combustion controls for heating, process heat and gas engines. Seven Star LLC sources and supplies DUNGS gas valves, regulators, pressure switches and valve proving systems for burner operators in Oman, identified by type designation and article number.

DUNGS product families listed here

The listed DUNGS gas valves and controls make up most of a burner gas train. The FRS is a spring-loaded gas pressure regulator in sizes from Rp 3/8 to DN 150. The GW A6 is a compact pressure switch for gas and air. DMV-D double solenoid valves, such as the DMV-D 507/11 and DMV-D 5125/11, combine two safety shut-off valves in one body, and the SV-D is a single safety solenoid valve. The MB-DLE 405 to 412 B01 GasMultiBloc integrates a filter, a regulator and two valves in one compact unit. The VPS 504 is a valve proving system that tests the tightness of the two shut-off valves before burner start.

Where DUNGS equipment is used

DUNGS combustion controls are fitted to steam and hot water boilers, thermal oil heaters, air heaters, dryers, ovens, kilns and furnaces, and to the fuel gas lines of gas engines. Buyers in the GCC typically need them as replacements on packaged burners in food plants, laundries, hospitals and building plant rooms.

Ordering DUNGS parts: what we need

Send the full type designation and the six-digit article number from the nameplate, for example VPS 504 S04 with 219881, a 230 V version. Add the coil voltage and frequency, the connection (Rp thread or flange DN), and the maximum inlet pressure. For an FRS regulator, state the outlet pressure and the spring range or spring color. For a GW pressure switch, state the setting range, which is part of the type name. For a MultiBloc, say whether operation is single-stage or two-stage. The burner make and model help us confirm the match.

Request a Quote for DUNGS Products

Looking for DUNGS parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine DUNGS products for customers across Oman and the GCC and replies with a formal quotation.

Free, no-obligation quotation · takes about 1 minute

Other enquiries: [email protected] · WhatsApp

Frequently Asked Questions

How do I identify a DUNGS valve from its nameplate?
The nameplate shows the type designation, such as DMV-D 507/11 or MB-DLE 407 B01, together with an article number, the voltage and frequency, protection class, maximum operating pressure and the approval mark. In the DMV and MultiBloc designations the digits indicate the nominal size. The article number identifies the exact version, so always include it.
What does the VPS 504 valve proving system do?
The VPS 504 checks the two safety shut-off valves for leakage before the burner starts. An internal motor pump raises the pressure in the space between the valves by about 20 mbar above the inlet pressure, and a differential pressure switch monitors whether it holds. If it does, the burner control receives a release signal. Versions differ in voltage and in their electrical connection to the burner control.
How do I choose the right spring for a DUNGS FRS regulator?
The FRS outlet pressure range is set by the spring fitted, and DUNGS identifies the springs by number and color, each covering a defined outlet pressure band, for example 5 to 20 mbar or 25 to 55 mbar. If the required outlet pressure is outside the band of the installed spring, the spring is changed, not the regulator. Send the regulator size, the inlet pressure and the outlet pressure you need.
Which approvals does DUNGS issue for its gas valves and pressure switches?
DUNGS safety shut-off valves are built to EN 161, the European standard for automatic shut-off valves on gas burners, and the nameplate shows the valve class and the approval mark. Regulators and pressure switches have their own product standards. The approval is specific to the version, and on request we provide the declaration of conformity that the manufacturer issues.
Is Seven Star LLC a distributor of DUNGS?
No. Seven Star LLC is an independent supplier. We source DUNGS products through commercial channels, check the type designation and article number against the manufacturer's documentation, and provide the manufacturer's datasheet and declaration of conformity with the order on request. A nameplate photo sent with the inquiry is the best starting point.