Brand:

Danfoss MBS 5100 Pressure Transmitter

Description

Overview

The Danfoss MBS 5100 is a ship-approved, high-accuracy block-type pressure transmitter engineered for use across almost all marine and general industrial applications. The Danfoss MBS 5100 pairs an acid-resistant AISI 316L wetted pressure connection with fully digitally compensated electronics, delivering an accuracy of ±0.1% FS (typical) and a 4…20 mA output signal across pressure ranges spanning 0…2.5 bar up to 0…400 bar, making a single sensor family suitable for everything from low-pressure HVAC circuits to high-pressure hydraulic and fuel systems.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the Danfoss MBS 5100 pressure transmitter to marine engineers, HVAC contractors, and industrial maintenance teams across Oman and the wider GCC, with technical support and lead time confirmed at quotation for time-critical vessel and plant turnarounds.

Measurement Principle

The Danfoss MBS 5100 uses a robust piezoresistive sensing element mounted directly in the pressure block, with the resulting analogue signal digitally compensated for temperature and non-linearity effects before being output as a stable 4…20 mA current loop. This block-type construction places the sensing element in direct contact with the process media through the G1/4 female pressure connection, eliminating the transfer fluids or diaphragm seals that introduce lag and additional failure points in some transmitter designs, while non-linearity is held to ≤ ±0.2% FS (BFSL) across the compensated temperature range.

Because the MBS 5100 is fully digitally compensated at the point of manufacture, it requires no field adjustment of zero or span for standard applications, and its acid-resistant stainless steel wetted parts allow direct exposure to seawater, fuel, and hydraulic media without a separate isolation diaphragm. This translates into no moving parts in the pressure path, no measurable pressure drop introduced into the line, and strong resistance to the cavitation and liquid-hammer events common in marine piping systems and pump discharge lines.

Engineering Design of the Danfoss MBS 5100

The Danfoss MBS 5100 is built around a compact block-type body with a G1/4 female pressure connection sized for direct manifold mounting, and an angular DIN 175301-803-A electrical connector (Pg11) that simplifies field wiring and cable strain relief in confined engine-room and skid environments. The transmitter’s rated IP65 enclosure and −40…85°C ambient operating range make it suitable for both climate-controlled machinery spaces and exposed GCC outdoor installations subject to intense solar loading.

Overload pressure ratings of up to twice the nominal span, combined with excellent vibration stability and high EMC/EMI protection, allow the MBS 5100 to be mounted directly on engines, compressors, and pump skids where mechanical shock and electrical noise would degrade a less-robust transmitter. The sensor is UL approved and carries a range of marine classification-society approvals, giving specifiers confidence for both newbuild and retrofit marine instrumentation projects as well as onshore industrial installations that value the same proven, rugged design.

Beyond its marine classification pedigree, the Danfoss MBS 5100 is independently certified by an unusually broad span of classification societies, including Det Norske Veritas (DNV), Lloyd’s Register (LR), the American Bureau of Shipping (ABS), Bureau Veritas (BV), RINA, Nippon Kaiji Kyokai (NKK), the Korean Register (KR), and China Classification Society (CCS), giving specifiers on multinational newbuild and retrofit projects a single transmitter model that satisfies whichever society is surveying the vessel. Electrical termination is available with an EN 175301-803-A angular plug in M20, Pg9, or Pg11 thread options, or without a mating plug where the customer supplies its own cable gland, and the transmitter’s short-circuit-protected 4…20 mA output is powered from a 9…32 VDC supply with reverse-polarity protection built in. Response time is under 4 ms for liquid media below 100 cSt viscosity and under 35 ms for gases, and the sensing element is rated for more than 10 million pressure cycles with a calculated mean time to dangerous failure exceeding 100 years, underscoring the transmitter’s suitability for continuous, unattended service in machinery spaces.

The transmitter is tested to sinusoidal vibration of 15.9 mm peak-to-peak (5–25 Hz) and 20g (25 Hz–2 kHz), random vibration of 7.5 grms, mechanical shock of 500g/1ms, and a 1 metre free-fall drop — levels reflecting sustained engine-room vibration and occasional handling impact. Static overload reaches six times nominal span (max 1500 bar) and burst pressure six times span (max 2000 bar); EMC performance is certified to EN 61000-6-3/6-2, with an ATEX Zone 2 variant available under EN 60079-0/-7 for classified areas such as tank farms.

Key Features

The Danfoss MBS 5100 pressure transmitter delivers marine-grade reliability that translates directly into value for Oman’s industrial, HVAC, and port-facility markets.

  • Acid-resistant AISI 316L wetted parts withstand seawater, fuel, and hydraulic media without a separate diaphragm seal.
  • Accuracy of ±0.1% FS typical (≤0.3% FS max) suits demanding process-control applications.
  • Fully digitally compensated electronics eliminate the need for field zero/span adjustment.
  • 4…20 mA two-wire output integrates directly into existing analogue instrumentation loops.
  • Pressure ranges from 0…2.5 bar to 0…400 bar cover HVAC, hydraulic, and high-pressure fuel systems.
  • Excellent vibration stability and high EMC/EMI protection suit engine-mounted and skid installations.
  • Ship approvals from major classification societies support marine newbuild and retrofit projects.
  • IP65-rated angular DIN connector and −40…85°C rating suit exposed GCC outdoor and machinery-space duty.

Industrial Applications

The Danfoss MBS 5100 is widely specified for marine engine-room pressure monitoring, HVAC and refrigeration circuits, hydraulic power units, and compressed-air and fuel-oil systems, wherever a rugged, digitally compensated block transmitter is needed to withstand vibration, cavitation, and liquid-hammer stress. In Oman, typical installations include port and marine terminal equipment pressure monitoring, HVAC chiller-plant pressure control in commercial and hospitality developments, and hydraulic system monitoring on heavy machinery serving the Sultanate’s logistics and industrial sectors.

With fast quotation turnaround and technical support, Seven Star LLC distributes the MBS 5100 pressure transmitter to marine operators, HVAC contractors, and industrial plants throughout Muscat, the Sohar and Salalah port and free zones, and neighboring GCC states, supporting district cooling plants, RO desalination pump skids, and hospital and hospitality-chain mechanical systems that depend on dependable, ship-grade pressure sensing.

Technical Specifications

The table below summarizes the core specifications relevant to sizing and installing the Danfoss MBS 5100 pressure transmitter.

Parameter Specification
Model Danfoss MBS 5100
Pressure range 0…2.5 bar up to 0…400 bar (variant-dependent)
Accuracy ±0.1% FS typical, ≤±0.3% FS max
Non-linearity (BFSL) ≤ ±0.2% FS
Output signal 4…20 mA, 2-wire
Wetted material Acid-resistant stainless steel AISI 316L
Pressure connection G1/4 female
Electrical connection Angular DIN 175301-803-A connector, Pg11
Supply voltage DC 9…32 V
Ambient/medium temperature −40…85°C
Protection rating IP65
Approvals DNV, LR, ABS, BV, RINA, NKK, KR, CCS; ATEX Zone 2 (EN 60079-0/-7)
Response Time <4 ms (liquids <100 cSt), <35 ms (gases)
Overpressure / Burst 6× FS static (max 1500 bar) / 6× FS burst (max 2000 bar)

Request a Quote for Danfoss MBS 5100 Pressure Transmitter

Seven Star LLC invites marine engineers, HVAC contractors, and industrial maintenance teams across Oman and the GCC to submit a formal RFQ for the Danfoss MBS 5100 pressure transmitter. With engineering support in Muscat, we supply on request with lead time confirmed at quotation, provide the full technical datasheet on request, and connect buyers directly with our instrumentation division for pressure-range selection, marine classification guidance, and technical support.

Related Products

Datasheets & Documents
  • PDF Datasheet Danfoss MBS 5100 Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss MBS 5100 Pressure Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What pressure ranges are available for the Danfoss MBS 5100?
The MBS 5100 is available across a wide range of factory-set spans, from 0 to 2.5 bar up to 0 to 400 bar, with accuracy of ±0.1% FS typical, allowing selection of the correct range for HVAC, hydraulic, or high-pressure fuel applications.
02Is the MBS 5100 approved for marine use?
Yes. The MBS 5100 is a ship-approved transmitter carrying approvals from major marine classification societies, and its acid-resistant AISI 316L wetted parts, vibration stability, and EMC/EMI protection suit engine-room and offshore installations.
03What wetted materials does the MBS 5100 use?
The MBS 5100 pressure connection is manufactured from acid-resistant stainless steel AISI 316L, giving it broad compatibility with seawater, fuel, hydraulic fluid, and most industrial process media without a separate isolation diaphragm.
04Can the MBS 5100 replace an older analogue pressure transmitter?
Yes. Its standard 4 to 20 mA two-wire output and G1/4 female process connection allow it to directly replace legacy analogue pressure transmitters on existing piping and control wiring without modification.
05Is Seven Star LLC an experienced supply partner for Danfoss products?
Yes, Seven Star LLC is an experienced supplier of Danfoss in Oman and the GCC, supplying MBS 5100 transmitters with local technical support.