Brand:

Danfoss 032B2004 CSV 6 Solenoid Valve, 12 mm ODF, NC

Description

CSV 6: a compact 12 mm solenoid valve body for small refrigeration systems

Danfoss 032B2004 is a CSV 6 solenoid valve body, normally closed, with 12 mm ODF solder connections. The CSV is a compact valve with a 5.6 mm orifice, a Kv value of 0.54 m3/h and a net weight of only 0.08 kg. It is supplied without a coil and has a smaller 9 mm actuator system than the EVR.

The maximum working pressure is 45 bar (653 psig), the medium temperature range is -40 to 120 C and the ambient range is -20 to 55 C. MaxOPD with a 7 W AC coil is 35 bar (508 psi), and the minimum opening differential is 0.05 bar (1 psi). Approvals shown are EAC, cURus and UA.

Technical specifications

Parameter Specification
Danfoss code number 032B2004
Type CSV 6
Ambient temperature -20 – 55 C
Approvals as listed EAC; cURus; UA
Function NC
Inlet connection type Solder, ODF
Inlet size 12 mm
Kv value 0.54 m3/h
Maximum working pressure 45 bar
MaxOPD 7W AC 35 bar
Medium temperature range -40 C to 120 C
MinODP 0.05 bar
MOPD Coil Dependent
Orifice size 5.6 mm
Outlet connection type Solder, ODF
Outlet size 12 mm
Refrigerants R1234ze(E); R134a; R22/R407C; R290; R404A/R507A; R452A; R513A; R600; R600a
Type designation Solenoid valve
Net weight 0.08 kg
EAN 5702428478182

The compact solenoid for small circuits

This CSV is for commercial refrigeration, beverage cooling, small chillers and heat-pump circuits where space is tight. Its refrigerant list includes R1234ze(E), R134a, R22/R407C, R290, R404A/R507A, R452A, R513A, R600 and R600a, so it can be used with several hydrocarbon charges as well as HFCs; always check the flammable-refrigerant requirements of the system.

The valve has no spare parts and no manual operation according to the page, so it is a replace-as-unit component. The data sheet pair for the CSV 2 – CSV 22 gives capacities and dimensions for the whole range.

Ordering notes

Choose the coil (voltage, 7 W class) separately and check that it fits the 9 mm actuator. Install with the coil above the body, brazing with the body cooled, and fit a filter-drier ahead. Hydrocarbon systems may require special coils and cabling; confirm that with the equipment manufacturer.

Confirm the connection diameter (12 mm ODF), the function (NC) and the maximum differential at the highest condensing pressure. Two data sheets exist for the type; the attached one is the current CSV 2 – CSV 15 sheet.

Other types and sizes from the same Danfoss family that appear in the Danfoss store listing include CSV 2 (032B2000), CSV 3 (032B2001), CSV 10 (032B2005), CSV 15 (032B2007). These are listed for orientation only; each has its own datasheet values, so check size, connection and version before ordering.

Related Danfoss products: Danfoss 032L1045 EVR 40 Solenoid Valve 2 1/8 in Solder NO, Danfoss 032L1188 EVR 10 Solenoid Valve 1/2 in Solder NC, Danfoss 032U7132 EV220B 32 Solenoid Valve G 1 1/4 NC, Danfoss 032U3806 EV225B 20 Steam Solenoid Valve G 3/4 NC, Danfoss 032U5254 EV250B 18 Solenoid Valve G 3/4 NC 0 bar and Danfoss 032U7115 EV220B 15 Solenoid Valve G 1/2 NC EPDM.

Documents and quotation

The reference document for this code is the Danfoss Solenoid valve and coil Type CSV 2 – CSV 22 AI153586441354en-000901 (manufacturer, unaltered), attached as the unaltered manufacturer PDF. See also solenoid valves. Request a price for 032B2004 by sending the quantity; Seven Star LLC is an independent supplier in Muscat.

Datasheets & Documents
  • PDF Datasheet Danfoss Solenoid valve and coil Type CSV 2 - CSV 22 AI153586441354en-000901 (manufacturer, unaltered) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 032B2004 CSV 6 Solenoid Valve, 12 mm ODF, NC

Answers from our engineering team on installation, compatibility and integration.

01What is Danfoss 032B2004?
A CSV 6 normally closed solenoid valve body with 12 mm ODF solder connections and a 5.6 mm orifice.
02What is the Kv value?
0.54 m3/h.
03Can the valve be serviced?
No, the page lists spare parts as not available.
04Is the coil included?
No, order the coil separately.
05Which document is attached?
The Danfoss solenoid valve CSV 2 - CSV 15 data sheet AI550531903888en-000101.