Danfoss iC2-Micro Frequency Converter 0.37-22 kW
Description
Overview
The Danfoss iC2-Micro is a compact general-purpose frequency converter for motors from 0.37 kW to 22 kW. Danfoss introduced it as the successor to the VLT® Micro Drive FC 51, which has now reached the Limited phase of its lifecycle and is no longer produced. The Danfoss iC2-Micro keeps the small footprint and simple commissioning that made the FC 51 popular in panels and machines, and adds permanent magnet motor control, locked motor detection, torque open loop control and connectivity with the MyDrive® Suite tools.
Seven Star LLC supplies the Danfoss iC2-Micro to panel builders, OEMs and maintenance teams in the Sultanate of Oman and the GCC, with engineering support in Muscat. For plants that still run FC 51 micro drives, we help match the power rating, supply voltage and I/O so the Danfoss iC2-Micro can be fitted as a straightforward replacement.
Operating Principle
Like any voltage-source inverter, the Danfoss iC2-Micro rectifies the incoming 50/60 Hz supply to a DC link and then synthesises a variable-voltage, variable-frequency output for the motor, from 0 to 500 Hz. Varying the output frequency changes the motor speed, so a fan or pump runs only as fast as the process needs, which is where most of the energy saving in variable-torque applications comes from. Ramp times from 0.01 to 3,600 s allow a gentle start that limits mechanical stress and water hammer.
The drive uses VVC+ voltage-vector control and provides efficient open-loop control of permanent magnet motors across the whole power range, as well as induction motors. Overload capacity is 150 % for 60 s every 10 minutes, with 200 % for 1 s at start, which covers the breakaway torque of conveyors and positive displacement pumps. An integrated PID controller allows closed-loop pressure or flow control from a transmitter signal without a separate controller.
Engineering Design of the Danfoss iC2-Micro
The Danfoss iC2-Micro integrates components that often have to be added externally: a control panel with LED display and indicators, a potentiometer for local setpoints, an RFI filter (in the filtered variant), a brake chopper and intelligent cooling. Seven enclosure sizes from MA01c to MA05a cover the range, the smallest measuring 150 × 70 × 143 mm and weighing about 1 kg. Printed circuit boards are coated, no forced air passes over the PCBs, the fan is removable and switched on only when needed, and the smallest single-phase units are cooled naturally without a fan.
Control wiring uses spring-type I/O terminals: five digital inputs and one digital output, pulse input and output, two analog inputs for 0–10 V or 0/4–20 mA, one 0/4–20 mA analog output and one relay output rated 240 V AC, 2 A. An RJ45 port based on RS485 connects the optional remote control panel, which has a 2.0 inch display, multi-language text and parameter copy, or a PC for offline configuration. Drives can be mounted side by side and operate at up to 50 °C without derating.
Key Features
The drive brings these advantages to small motor applications:
- Designed by Danfoss as the replacement for the VLT Micro Drive FC 51 in existing plants.
- Permanent magnet motor control in open loop under VVC+ across the whole power range, as well as induction motor control.
- Integrated brake chopper and PID controller reduce external components and cost.
- Operation at up to 50 °C without derating suits hot control rooms and outdoor kiosks.
- Coated PCBs and no forced air over the electronics improve reliability in dusty and humid environments.
- Spring-type I/O terminals and application set-up wizards shorten installation and commissioning.
- Two versions, with or without EMC filter, let the buyer match the electrical environment.
- Side-by-side mounting and compact enclosures save cabinet space.
Industrial Applications
Danfoss names fans, pumps, conveyors and textile machines as the main duties for the Danfoss iC2-Micro. In Oman and the GCC it is a practical choice for ventilation and extraction fans in plant buildings, cooling tower fans, small booster and dosing pumps in water treatment, packaging and bottling conveyors, mixers and agitators, and HVAC equipment in commercial buildings, hospitals and hotels. In larger installations it often works alongside the Danfoss VLT HVAC Drive FC 102 for air handling units and the Danfoss VLT AutomationDrive FC 302 for heavier process duty.
For sites replacing failed FC 51 units, the Danfoss iC2-Micro covers the same supply voltages and power ranges, and Danfoss provides a retrofit tool in MyDrive Assistant. Existing FC 51 accessories such as the Danfoss LCP 12 control panel belong to the older drive, so the optional iC2 remote panel should be specified for the new unit. Seven Star LLC supplies the Danfoss iC2-Micro across Oman, the UAE, Saudi Arabia, Qatar, Kuwait and Bahrain.
Technical Specifications
The following data are taken from the Danfoss iC2-Micro fact sheet.
| Parameter | Specification |
|---|---|
| Model | Danfoss iC2-Micro frequency converter |
| Predecessor | VLT® Micro Drive FC 51 |
| Power range | 1 × 200–240 V: 0.37–2.2 kW; 3 × 380–480 V: 0.37–22 kW; 1 × 100–120 V: 0.37–1.1 kW; 3 × 200–240 V: 0.37–11 kW |
| Supply tolerance / frequency | −15 % / +10 %; 50/60 Hz |
| Displacement power factor | > 0.98 |
| Output frequency | 0–500 Hz |
| Ramp times | 0.01–3,600 s |
| Overload | 150 % for 60 s every 10 min; 200 % for 1 s at start |
| Digital I/O | 5 inputs / 1 output (PNP or NPN, 0/24 V DC); 1 pulse input, 1 pulse output |
| Analog I/O | 2 inputs (0–10 V or 0/4–20 mA); 1 output (0/4–20 mA) |
| Relay output | 1 (NO/NC, 240 V AC 2 A / 30 V DC 2 A) |
| Integrated functions | Control panel, potentiometer, brake chopper, PID controller, RFI filter (filtered version) |
| Ambient | Up to 50 °C without derating |
| Enclosure sizes | MA01c, MA02c, MA01a–MA05a |
Enclosure dimensions and weights from the fact sheet:
| Enclosure | Height (mm) | Width (mm) | Depth (mm) | Weight (kg) |
|---|---|---|---|---|
| MA01c | 150 | 70 | 143 | 1.0 |
| MA02c | 176 | 75 | 157 | 1.3 |
| MA01a | 150 | 70 | 158 | 1.1 |
| MA02a | 186 | 75 | 175 | 1.6 |
| MA03a | 238.5 | 90 | 200 | 3.0 |
| MA04a | 292 | 125 | 244.5 | 6.0 |
| MA05a | 335 | 165 | 248 | 9.4 |
How to Order
Send Seven Star LLC the motor power, supply voltage and application, or the type label of the FC 51 you are replacing, and we will select the right Danfoss iC2-Micro rating and options. Our Muscat office advises on stock and delivery in Oman and the GCC and can share the Danfoss iC2-Micro fact sheet for your records.
Datasheets & Documents
- Fact sheet Danfoss iC2-Micro Fact Sheet (AM414644741332en-000501) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss iC2-Micro Frequency Converter 0.37-22 kW
Answers from our engineering team on installation, compatibility and integration.
01Does the Danfoss iC2-Micro replace the VLT Micro Drive FC 51?
Yes. Danfoss states that the iC2-Micro succeeds the FC 51 and is designed to replace it smoothly in established plants. The FC 51 is in the Limited lifecycle phase and no longer produced.
02What power range does the Danfoss iC2-Micro cover?
It covers 0.37-2.2 kW on 1 x 200-240 V, 0.37-22 kW on 3 x 380-480 V, 0.37-1.1 kW on 1 x 100-120 V and 0.37-11 kW on 3 x 200-240 V.
03Can the Danfoss iC2-Micro run permanent magnet motors?
Yes. It provides open-loop permanent magnet motor control under VVC+ across the whole power range, as well as standard induction motor control.
04Does the Danfoss iC2-Micro need derating in hot climates?
The fact sheet states operation at up to 50 C without derating, which helps in hot Gulf control rooms. Installation conditions should still be checked against the manual.
05Can Seven Star LLC supply the Danfoss iC2-Micro in Oman?
Yes. Seven Star LLC supplies Danfoss iC2-Micro drives across Oman and the GCC, with engineering support in Muscat.