- Automation & ControlView all 2,956 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Danfoss
Danfoss EVR 25 Servo-Operated Solenoid Valve
Description
Overview
Danfoss EVR 25 is a servo-piston operated solenoid valve from Danfoss’s widely deployed EVR range, purpose-built for precise on/off control of refrigerant flow in liquid, suction, and hot gas lines. Used across commercial refrigeration and air conditioning systems worldwide, the EVR 25 pairs a robust brass valve body with an easy-to-service, clip-on coil design that allows technicians to service the coil and internal parts without removing the valve body from the pipeline — a detail that meaningfully reduces system downtime and refrigerant loss during maintenance.
Working closely with plant engineers in the region, Seven Star LLC proudly supplies the Danfoss EVR 25 and the full EVR solenoid valve range to customers across Oman and the wider GCC. Facility engineers and contracting teams in Muscat, Sohar, and Salalah rely on Seven Star LLC for Danfoss valve bodies and coils, with technical support suited to the region’s demanding cooling and process-refrigeration loads.
Operating Principle
The EVR 25 is a normally closed, servo-operated piston valve. When the coil is de-energized, the piston and valve plate are held closed against the valve seat by the differential pressure between the inlet and outlet sides, combined with the force of a return spring and the weight of the piston assembly. This design keeps the valve reliably sealed with zero manual intervention whenever power is removed, which is an important safety and control characteristic for unattended refrigeration plant.
When the coil is energized, the pilot orifice located in the valve cover opens, relieving pressure on the spring side of the piston. The resulting pressure differential across the piston lifts it off the seat, opening the main valve to admit full flow. A minimum differential pressure of around 0.07 bar (1 psi) is required to open the valve and to keep it fully open during operation. Because the valve has no packing gland or stem seal exposed to the refrigerant path, there is no dynamic seal to wear out under cycling, which translates into a long, low-maintenance service life and a dependable shut-off with minimal risk of internal leakage past the seat.
Engineering Design of the Danfoss EVR 25
The Danfoss EVR 25 valve body is precision-machined brass, fitted with solder ODF connections sized 28 mm (1-1/8 in) or 35 mm (1-3/8 in), with a 25 mm port and Cv value of 12.0 gal/min, giving it the flow capacity to serve mid-to-large commercial liquid, suction, and hot gas circuits. Extended solder connections mean the valve body does not need to be dismantled during pipe soldering, protecting the internal seals and diaphragm from heat damage during installation — a practical advantage on retrofit and brownfield refrigeration jobs.
Above the valve body sits a clip-on coil, available in both AC (24–240 V, 50/60 Hz) and DC (12–220 V) versions, each interchangeable across the EVR body range without tools. AC coils are offered in junction box (NEMA 1/IP54) or conduit boss (NEMA 4/IP54) termination styles, while DC coils are rated to IP67 (NEMA 6) for wash-down or exposed outdoor installation. Class H insulated coil wire supports continuous duty across an ambient range of –40°C to +50°C, and the coil, armature, and pilot assembly can all be replaced as spare parts in the field without breaking the refrigerant circuit.
Key Features
The Danfoss EVR 25 delivers dependable refrigerant shut-off with a feature set built around service life and installation flexibility. Key characteristics of the Danfoss EVR 25 include:
- Servo-piston operation provides reliable, tight shut-off in liquid, suction, and hot gas refrigerant lines.
- Normally closed (NC) configuration with de-energized coil ensures fail-safe closure on power loss.
- Wide range of clip-on AC and DC coils, interchangeable without dismantling the valve body.
- Coil enclosure options up to IP67 (NEMA 6) support harsh, humid, or outdoor installation environments.
- Compatible with fluorinated refrigerants and most hydrocarbon refrigerants used in modern HVAC-R systems.
- Rated for media temperatures up to 105°C continuous, and up to 130°C during hot gas defrost cycles.
- Maximum working pressure of approximately 32 bar (460 psig) suits medium and high-pressure refrigeration circuits.
- Extended solder ODF connections allow pipe soldering without dismantling internal valve components.
Industrial Applications
The Danfoss EVR 25 solenoid valve is deployed throughout commercial and industrial refrigeration and air conditioning: cold storage warehouses, supermarket and hypermarket refrigeration racks, chiller and condensing unit liquid lines, hot gas defrost circuits, and central plant suction lines feeding multiple evaporators. Its mid-size flow capacity makes it a common choice for district cooling plant rooms, food and beverage cold chain facilities, and packaged chiller systems where reliable, fail-safe shut-off is required at each branch line.
With fast quotation turnaround and technical support, Seven Star LLC distributes the EVR 25 and related refrigeration valve components to cold chain operators, HVAC contractors, and industrial refrigeration integrators across the Sultanate of Oman and the GCC, including projects in the Sohar and Salalah free zones. Regional customers in food processing, hospitality, and commercial building services depend on Seven Star LLC to supply genuine Danfoss valve bodies, coils, and spare parts with the local technical support needed to keep cooling plant running reliably through Oman’s peak-demand summer months.
Technical Specifications
Key technical data for the Danfoss EVR 25 servo-operated solenoid valve is summarized below; the Danfoss EVR 25 datasheet figures are listed for reference during system sizing.
| Parameter | Specification |
|---|---|
| Model | Danfoss EVR 25 |
| Valve Type | Servo-piston operated solenoid valve, normally closed (NC) |
| Connection | Solder ODF, 28 mm (1-1/8 in) or 35 mm (1-3/8 in) |
| Port Size | 25 mm (1 in) |
| Cv Value | 12.0 gal/min |
| Refrigerant Compatibility | Fluorinated refrigerants (R22, R134a, R404A, R507, etc.) and most hydrocarbons |
| Media Temperature Range | –40°C to +105°C (up to +130°C during defrost) |
| Maximum Working Pressure | ≈32 bar (460 psig) |
| Minimum Opening Differential Pressure | ≈0.07 bar (1 psi) |
| Coil Voltage (AC) | 24–240 V, 50/60 Hz |
| Coil Voltage (DC) | 12–220 V |
| Coil Enclosure | NEMA 1/2 (IP54) junction box or NEMA 4/6 (IP54–IP67) conduit/terminal box |
| Coil Insulation | Class H per IEC 85 |
| Ambient Temperature | –40°C to +50°C |
| Body Material | Brass |
| Approvals | UL listed (file MH 7648), LVD 73/23/EC compliant |
Request a Quote for Danfoss EVR 25 Servo-Operated Solenoid Valve
Contact Seven Star LLC to request a formal quotation for the Danfoss EVR 25 solenoid valve or any model across the EVR range — our team can confirm Danfoss EVR 25 lead times and current availability on request. With engineering support in Muscat, Seven Star LLC supplies on request, provides technical datasheets on request, and connects customers directly with our instrumentation and refrigeration controls division for sizing support, coil selection, and project-specific configuration across cold storage, HVAC-R, and process cooling applications.
Related Products
- Dungs SV-D 505 Safety solenoid valve Nominal width Rp 1/2 – Rp 2
- Parker Lucifer 341N31 NAMUR Solenoid Valve
- Norgren V51B517A-A2000 5/2 Way Pneumatic Solenoid Valve
- SOLENOID VALVE “ALCO” OLD P.N: 211613
- Magnet-Schultz D-87700 Solenoid Actuator
- SOLENOID ACTUATED(SHUT OFF VALVE) NORGREN TYPE:85750
See also: Danfoss 032U5254 EV250B 18 Solenoid Valve G 3/4 NC 0 bar.
Datasheets & Documents
- Instruction Manual Danfoss EVR 25 Servo-Operated Solenoid Valve Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss EVR 25 Servo-Operated Solenoid Valve
Answers from our engineering team on installation, compatibility and integration.
01What refrigerants is the Danfoss EVR 25 compatible with?
The Danfoss EVR 25 is compatible with fluorinated refrigerants such as R22, R134a, R404A, and R507, as well as most hydrocarbon refrigerants used in commercial HVAC-R systems.
02Can the EVR 25 coil be serviced without removing the valve body?
Yes, the clip-on coil design lets technicians replace the coil, armature, or pilot assembly in the field without dismantling the valve body from the pipeline, significantly reducing downtime and refrigerant loss during service.
03What pipe sizes and connection types does the EVR 25 support?
The EVR 25 is available with solder ODF connections in 28 mm (1-1/8 in) or 35 mm (1-3/8 in) sizes, with a 25 mm port and a Cv value of 12.0 gal/min, suiting mid-to-large commercial liquid, suction, and hot gas lines.
04Is the Danfoss EVR 25 suitable for hot gas defrost applications?
Yes, the EVR 25 is rated for continuous media temperatures up to 105 degrees C and can withstand up to 130 degrees C during hot gas defrost cycles, making it suitable for defrost circuit control.
05Is Seven Star LLC an experienced supply partner for Danfoss products?
Yes, Seven Star LLC is an experienced supplier of Danfoss in Oman and the GCC, supplying EVR solenoid valves and refrigeration controls with local technical support.


















Reviews
There are no reviews yet.