Honeywell 2106B2310 is the Sensepoint high temperature flammable sensor, ATEX version, with an M20 thread. It is a catalytic bead head built for places where an ordinary detector would be at or beyond its limit, such as gas turbine enclosures and drying ovens. Honeywell quotes its operating range as -55 to +150 degrees C, compared with -40 to +80 degrees C for the standard 0 to 100 percent LEL Sensepoint sensor 2106B1200, and it is matched to the XCD RFD transmitter.

What makes 2106B2310 a high temperature head

The sensor uses thermally matched beads, which Honeywell says gives the best accuracy and stability at high temperature and allows low alarm levels. The datasheet’s performance table for the Sensepoint high temperature sensor lists T60 below 6 seconds and T90 below 10 seconds, accuracy of better than plus or minus 1.5 percent LEL, and default alarms of 20 and 40 percent LEL, with a selectable range from 20 to 100 percent LEL in 10 percent steps. The body is made of 316 stainless steel, unlike the PPS body of the standard sensor.

Specifications of 2106B2310

Parameter Value
Part number 2106B2310 (ATEX, M20 thread)
Sensor type Catalytic bead, thermally matched, high temperature
Operating temperature -55 to +150 degrees C
Selectable range 20 to 100 percent LEL, 10 percent steps; default 0 to 100 percent LEL
Default calibration 50 percent LEL
T60 / T90 Less than 6 s / less than 10 s
Accuracy Better than +/-1.5 percent LEL
Lowest alarm points As low as 5 percent LEL with the 0-20 percent LEL range
Body 316 stainless steel
Transmitter Sensepoint XCD RFD, up to 30 m from sensor

2106B2310 versus 2106B2311 and 2106B2312

The three high temperature ATEX heads share the same sensor and differ only in thread: 2106B2310 is M20, 2106B2311 is M25 and 2106B2312 is three-quarter inch NPT. Select the one that matches the junction box; the electrical and thermal data are the same for all three, so only the mechanical fit decides between them, and a mismatch means an adaptor or a new box. The 2106B2310 is also distinct from the standard sensor 2106B1200 in temperature rating, body material and response.

Gas turbine and oven applications of 2106B2310

The XCD RFD datasheet names two applications: use in and around gas turbine enclosures and in solvent-based printing and coating drying ovens, and compliance with HSE guidance note PM84. In these locations the sensor stays in the hot zone while the RFD transmitter, display and relays sit outside. Honeywell lists a high temperature Exe junction box 2052D0001 with three M20 entries and a high temperature single duct mounting assembly 90053-A-7041.

Installing 2106B2310

Think about the whole path from the 2106B2310 to the transmitter before ordering: the head, a cable gland, the cable and the junction box must all survive the temperature at the sensing point, and the transmitter should sit outside the hot zone where its display can be seen. The 30 metre limit applies to the cable between the 2106B2310 and the RFD transmitter. A separate limit applies between the transmitter and the controller: the datasheet gives 356 metres for 0.5 mm squared conductors and 1636 metres for 2.5 mm squared for catalytic installations on a 24 VDC supply. Check both distances for a new route, and remember that a long sensor cable adds resistance to the bridge circuit, so keep it as short as the installation allows.

Mount the sensor through a certified junction box whose temperature rating suits the location, with a cable and gland chosen for the same temperature. A cable of up to 30 metres links it to the SPXCDALMRFD or SPXCDASMRFD transmitter. The same head can be used with the XNX mV transmitter, which lists Sensepoint HT as a supported sensor.

The 2106B2310 is not a stand-alone transmitter. It is a mV catalytic bridge head that needs a bridge input on the receiving device. On the RFD transmitter, the user selects the gas and range at the LCD with the magnet, and sets the full scale from 100 percent LEL down to 20 percent LEL. The 20 percent LEL range is particularly suited to this head, because the thermally matched beads provide the accuracy and stability needed to alarm as low as 5 percent LEL. Check that the lowest alarm level you plan is within what the transmitter allows. A turbine enclosure that is cooled by ventilation air, where a gas leak must be detected while still small, is the classic fit for that narrow range.

Compared with the standard head, the datasheet shows a higher upper limit, a faster response and a stainless steel body, but the same alarm defaults, calibration point and accuracy statement. Operators who already have Sensepoint 0-100 percent LEL heads in service can keep the same RFD transmitter, controller scaling and spares of other parts, replacing only the sensor at the hot location. Where the sensing point is hotter than a standard head is rated for, a high temperature head is the straightforward choice.

When ordering, give the complete part number including the final digit, because 2106B2310, 2106B2311 and 2106B2312 are visually similar and differ only in thread, M20, M25 or three-quarter inch NPT. Also give the transmitter model so that compatibility can be checked, and the length of cable between the sensor and the transmitter, which Honeywell limits to 30 metres for the RFD.

Maintenance of 2106B2310

Calibration uses flammable gas through a flow housing at 1 litre per minute.

Documents and quotation

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The XCD RFD datasheet and the Sensepoint datasheet are available on request. Send an RFQ with 2106B2310, the quantity and the delivery location, and tell us the junction box thread.

Other Models in the Xcd Remote Range

Seven Star LLC supplies models from the Xcd Remote range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell SPXCDALMTX4 Sensepoint XCD RTD TransmitterFire & Gas DetectorsView details
Honeywell SPXCDASMRFD Sensepoint XCD RFD TransmitterFire & Gas DetectorsView details
Honeywell 2106B2310 Sensepoint HT Flammable Sensor M20Fire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Sensepoint XCD RFD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell 2106B2310 Sensepoint HT Flammable Sensor

Answers from our engineering team on installation, compatibility and integration.

01What temperature range does Honeywell 2106B2310 handle?
The Sensepoint high temperature flammable sensor operates from -55 to +150 degrees C according to the XCD RFD datasheet.
02Which transmitters can the 2106B2310 work with?
It is intended for the Sensepoint XCD RFD transmitter, and the XNX datasheet also lists Sensepoint HT as a supported sensor for its mV personality.
03How fast does 2106B2310 respond?
The performance table shows a T60 below 6 seconds and a T90 below 10 seconds, with accuracy better than plus or minus 1.5 percent LEL.
04What are the other threads for this sensor?
2106B2311 is the M25 version and 2106B2312 is the three-quarter inch NPT version of the high temperature ATEX sensor.
05Why use 2106B2310 instead of 2106B1200?
The 2106B2310 operates up to 150 degrees C with thermally matched beads, while the standard 2106B1200 is specified to 80 degrees C.