Honeywell STD775 SmartLine STD700 High Range DP Transmitter
Description
Honeywell STD775 in brief
Honeywell STD775 is the high-differential body in the STD700 SmartLine series. Where the STD725 and STD735 are chosen for flow and filter work, the STD775 is for service where several hundred psi of differential appear across the sensor, such as boiler feed pump recirculation, high-pressure separator interface and compressor seal gas filtering.
Its range window runs from minus 100 psi (minus 7.0 bar) to 3,000 psi (210 bar) with a minimum span of 30 psi (2.1 bar), which limits turndown to the quoted 100:1. Although the sensing element is the same piezoresistive design as its siblings, the STD775 is calibrated against a much higher pressure so the accuracy coefficients are tuned for a coarser span.
What the STD775 brings to a loop
- Range limits of minus 100 psi to 3,000 psi (minus 7.0 to 210 bar).
- Reference turndown 10:1 and knee C of 300 psi (21 bar).
- Temperature effect 0.070 plus 0.015 times URL over span per 28 degC.
- Static pressure effect 0.100 plus 0.020 times URL over span per 1,000 psi.
- Total performance of 0.252 percent of span at 600 psi, 5:1 turndown, from the datasheet example.
- Quoted over-range safety: overpressure 1.5 times MAWP, with no-burst pressure of 2.5 times MAWP plus 1,000 psi above 2,000 psi MAWP.
STD775 datasheet values
| Parameter | Value |
|---|---|
| Model | STD775 (STD700 SmartLine differential pressure) |
| Upper range limit | 3000 psi (210 bar) |
| Lower range limit | -100 psi (-7.0 bar) |
| Minimum span | 30 psi (2.1 bar) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.05 percent of span (A 0.005, B 0.045) |
| Reference turndown | 10:1; accuracy knee C = 300 psi (21 bar) |
| Temperature effect | 0.070 + 0.015 x URL/span, percent of span per 28 degC |
| Static pressure effect | 0.100 + 0.020 x URL/span, percent of span per 1,000 psi |
| Total performance example | 0.252 percent of span at 600 psi, 5:1 turndown |
| Output / protocol | Two-wire 4 to 20 mA with HART 7 |
| Supply voltage and loop load | 10.8 to 42.4 VDC at the terminals (intrinsically safe versions limited to 30 VDC); load 0 to 1,440 ohms |
| Response time | 100 ms (delay plus time constant); turn-on time 2.5 s |
| Damping | 0 to 32 s in 0.1 s steps, default 0.50 s |
| Ambient temperature (rated) | -40 to 85 degC; storage -55 to 120 degC |
| Meter body temperature (rated) | -40 to 110 degC; operative limit 125 degC |
| Maximum allowable working pressure | 4,500 psi (310 bar); overpressure 1.5 x MAWP |
| Process connection | 1/4-inch NPT, or 1/2-inch NPT with adapter (DIN requirements met) |
| Wetted diaphragm | 316L stainless steel or Hastelloy C-276 |
| Fill fluid | Silicone 200 or CTFE |
| Housing | Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional |
| Net weight | 8.3 lb (3.8 kg) with aluminium housing |
How STD775 differs from other STD700 variants
The distinguishing number is the 30 psi (2.1 bar) minimum span, thirty times that of the STD735. Buyers sometimes order the STD775 for a 0 to 50 psi loop simply because the line static pressure is high; the datasheet logic says otherwise, since static pressure is handled by the static pressure compensation, not by the range. Choose the STD775 only when the differential itself can exceed about 100 psi.
Compared with the STD725 the accuracy knee moves from 25 inH2O (62.5 mbar) to 300 psi (21 bar), meaning its base accuracy holds down to a span of 300 psi while smaller spans scale with the A plus B times C over span expression.
| Model | Ref. turndown | Knee C | Total performance example |
|---|---|---|---|
| STD725 | 16:1 | 25 inH2O | 0.270% at 80 inH2O |
| STD735 | 4:1 | 25 psi | 0.255% at 20 psi |
| STD775 | 10:1 | 300 psi | 0.252% at 600 psi |
Where STD775 earns its place in Oman and the GCC
In upstream oil and gas, differential pressure at this level appears across choke bodies, coalescer cartridges and sand filters on gas export lines. In power generation, the STD775 can monitor pressure drop across high-pressure feedwater heaters and control valves. Desalination plants in the Gulf use similar capacity transmitters on reverse osmosis high-pressure pump trains where differential across a cartridge filter can swing quickly.
The transmitter is also used for hydraulic test rigs and pressure-drop monitors on large lube-oil filters.
Choosing and pairing STD775
Specify the STD775 when peak differential is above 100 psi but below 3,000 psi. Confirm the bolting: standard is zinc-plated carbon steel, with 316 stainless, NACE A286 and super duplex options. For corrosive or sour media the datasheet offers NACE A286 bolting and Hastelloy C-276 diaphragms and heads.
Compare any replacement against the existing tag: check range, output, approval and fill fluid. The STD775 shares housings and electronics with the other STD700 models, so only the meter body differs.
Mounting, piping and commissioning STD775
Because the working pressures are high, torque flange bolts in a cross pattern to the values given in the installation manual, leak-test the manifold at static pressure, and bleed gas from the heads thoroughly. Mount in an orientation that keeps the process heads below the taps for gas service, and use isolating valves rated to the full line pressure.
After commissioning, perform a zero trim with both sides equalised under static pressure, because the 0.100 percent of span per 1,000 psi static effect is largely removed by this step.
Maintenance, diagnostics and spares
The 3,000 psi body is more affected by static pressure than lower ranges, so zero checks under line pressure are the preferred field test. Check for weeping at head gaskets, and replace glass-filled PTFE gaskets whenever the heads are opened. Diagnostics report excessive correction and sensor communication faults, both visible on the display.
Buyer questions on STD775
What is the range of the Honeywell STD775? The STD775 range runs from minus 100 psi (minus 7.0 bar) to 3,000 psi (210 bar) with a minimum span of 30 psi (2.1 bar).
Is the STD775 suitable for a 0 to 50 psi differential? The minimum span is 30 psi, so a 50 psi span is possible but not optimal; the STD735 is usually better for differentials below about 100 psi.
What fill fluids can the STD775 have? The STD700 datasheet lists silicone 200 and CTFE fill fluids.
What is the weight of the STD775? The datasheet gives a net weight of 8.3 lb (3.8 kg) with the aluminium housing.
Does the STD775 meet SIL requirements? The STD700 family is described as having full compliance to SIL 2/3 requirements.
Documents and quotation
Specification 34-ST-03-121 documents STD775 accuracy tables, approvals and dimensions; we can send it with the quotation.
To get a price for Honeywell STD775, send part number, quantity, calibrated range, approval type and any special bolting or gasket requirement to Seven Star LLC.
Other Models in the STD700 Range
Seven Star LLC supplies models from the STD700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STD725 SmartLine STD700 Differential Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STD735 SmartLine STD700 Differential Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STD775 SmartLine STD700 High Range DP Transmitter | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell STD775 SmartLine STD700 High Range DP Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STD775 SmartLine STD700 High Range DP
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STD775?
The STD775 range runs from minus 100 psi (minus 7.0 bar) to 3,000 psi (210 bar) with a minimum span of 30 psi (2.1 bar).
02Is the STD775 suitable for a 0 to 50 psi differential?
The minimum span is 30 psi, so a 50 psi span is possible but not optimal; the STD735 is usually better for differentials below about 100 psi.
03What fill fluids can the STD775 have?
The STD700 datasheet lists silicone 200 and CTFE fill fluids.
04What is the weight of the STD775?
The datasheet gives a net weight of 8.3 lb (3.8 kg) with the aluminium housing.
05Does the STD775 meet SIL requirements?
The STD700 family is described as having full compliance to SIL 2/3 requirements.


















Reviews