- Automation & ControlView all 2,859 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Honeywell
Honeywell STD725 SmartLine STD700 Differential Pressure Transmitter
Description
Honeywell STD725 in brief
Honeywell STD725 is the low-range member of the STD700 SmartLine differential pressure family, built for the measurements where a few millibar decide whether a loop is stable: furnace draft, filter and strainer differentials, low-head orifice runs and clean-room style pressure cascades. Its sensor is a single piezoresistive element that also reports static pressure and temperature to the electronics, so the transmitter corrects itself for line pressure and temperature rather than leaving that to the operator.
The upper range limit is 400 inH2O (1000 mbar) with the lower limit mirrored at minus 400 inH2O (minus 1000 mbar). Minimum span is 4 inH2O (10 mbar), which is where the quoted 100:1 maximum turndown comes from. If your engineering drawings list a 0 to 250 mbar or 0 to 100 inH2O calibration, the STD725 body is the one that covers it without a range swap. Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer.
What the STD725 brings to a loop
- Reference accuracy up to 0.05 percent of span, terminal based, including linearity, hysteresis and repeatability; the 4 to 20 mA output adds 0.006 percent of span.
- Stability of 0.020 percent of URL per year, quoted over ten years.
- Reference turndown of 16:1 before the accuracy formula starts to widen; the knee value is 25 inH2O (62.5 mbar).
- Static line pressure effect expressed as 0.100 plus 0.020 times URL over span, per 1,000 psi.
- Integral dual-seal construction to ANSI/NFPA 70 and ANSI/ISA 12.27.0, and SIL 2/3 capable design per the family datasheet.
- Three-button local configuration and optional LCD with four screens, rotatable in 90 degree steps.
STD725 datasheet values
| Parameter | Value |
|---|---|
| Model | STD725 (STD700 SmartLine differential pressure) |
| Upper range limit | 400 inH2O (1000 mbar) |
| Lower range limit | -400 inH2O (-1000 mbar) |
| Minimum span | 4 inH2O (10 mbar) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.05 percent of span (A 0.005, B 0.045) |
| Accuracy knee C | 25 inH2O (62.5 mbar) |
| Temperature effect | 0.050 + 0.025 x URL/span, percent of span per 28 degC |
| Static pressure effect | 0.100 + 0.020 x URL/span, percent of span per 1,000 psi |
| Total performance example | 0.270 percent of span at 80 inH2O, 5:1 turndown |
| Output / protocol | Two-wire 4 to 20 mA with HART 7 |
| Supply voltage and loop load | 10.8 to 42.4 VDC at the terminals (intrinsically safe versions limited to 30 VDC); load 0 to 1,440 ohms |
| Response time | 100 ms (delay plus time constant); turn-on time 2.5 s |
| Damping | 0 to 32 s in 0.1 s steps, default 0.50 s |
| Ambient temperature (rated) | -40 to 85 degC; storage -55 to 120 degC |
| Meter body temperature (rated) | -40 to 110 degC; operative limit 125 degC |
| Maximum allowable working pressure | 4,500 psi (310 bar); overpressure 1.5 x MAWP |
| Process connection | 1/4-inch NPT, or 1/2-inch NPT with adapter (DIN requirements met) |
| Wetted diaphragm | 316L stainless steel or Hastelloy C-276 |
| Fill fluid | Silicone 200 or CTFE |
| Housing | Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional |
| Net weight | 8.3 lb (3.8 kg) with aluminium housing |
How STD725 differs from other STD700 variants
Within the STD700 range the STD725 is the only model measured in inches of water. The STD735 spans 100 psi (7.0 bar) and the STD775 spans 3,000 psi (210 bar), so the STD725 offers a minimum span 7 times smaller in absolute terms than the STD735 would allow at the same turndown. The trade-off is a heavier temperature effect: 0.050 plus 0.025 times URL over span against 0.070 plus 0.015 for the two higher-range bodies, because a small span magnifies thermal drift.
The reference turndown also differs. The STD725 holds its base accuracy to 16:1, the STD735 to 4:1 and the STD775 to 10:1. For a draft or filter application that rarely uses more than 20 percent of the range this makes the STD725 the sensible pick; for a process line at several hundred psi static, move to the higher bodies instead.
| Model | URL | Min span | Ref. turndown |
|---|---|---|---|
| STD725 | 400 inH2O (1000 mbar) | 4 inH2O (10 mbar) | 16:1 |
| STD735 | 100 psi (7.0 bar) | 1 psi (0.07 bar) | 4:1 |
| STD775 | 3000 psi (210 bar) | 30 psi (2.1 bar) | 10:1 |
Where STD725 earns its place in Oman and the GCC
In Omani gas-processing plants and refinery utilities the STD725 is a natural fit for combustion air and flue-gas draft transmitters, where the range is a few hundred millimetres of water column and the loop must survive heat soak on a boiler casing. In water and wastewater, it measures differential across screens, sand filters and membrane pre-filters. In manufacturing halls across the GCC it serves HVAC air handling, spray-booth balance and dust-collector monitoring.
Square-root extraction is available in the display, so low-head orifice and venturi runs can be shown directly in flow units while the analog output still carries differential pressure.
Choosing and pairing STD725
Pick the STD725 when the maximum differential never exceeds 400 inH2O. If the line can see surge pressure from valve closure, remember that over-range protection is 1.5 times the 4,500 psi MAWP rating but that the sensor is happiest when static pressure stays within the process head limits of the chosen head material. Zinc-plated carbon steel heads are not recommended for water service; specify 316 stainless steel heads there.
Matching spares is simple: the meter body, display and electronics are modular, so an existing STD700 installation can take an STD725 meter body without changing the housing. Confirm the approval label you need (flameproof or intrinsically safe) at ordering.
Mounting, piping and commissioning STD725
Mount on a two-inch pipe with the supplied bracket in carbon steel, 304 or 316 stainless. For gas service put the transmitter above the taps and slope impulse lines upward; for liquid service put it below. Seal vent and drain plugs with PTFE tape, torque the process head bolts evenly, and keep low-range impulse lines short to avoid head errors.
After wiring, apply the supply (10.8 to 42.4 VDC), allow the 2.5 second start-up test, set zero with the process equalised, then verify span at one or two points. The device accepts up to 16 AWG conductors.
Maintenance, diagnostics and spares
Calibration verification is suggested every two years. Diagnostics split into critical items such as electronics module fault or meter body memory corruption and non-critical items such as display failure, all readable through the display, a Honeywell Versatilis handheld or Field Device Manager. Keep one spare electronics module and one display on the shelf; both can be swapped on site without recalibration of the meter body.
Buyer questions on STD725
What range does the Honeywell STD725 cover? The STD725 covers plus or minus 400 inH2O (plus or minus 1000 mbar) with a minimum span of 4 inH2O (10 mbar), giving up to 100:1 turndown.
What is the accuracy of the STD725? Reference accuracy is up to 0.05 percent of span with stability of 0.020 percent of URL per year over ten years, from the STD700 datasheet.
Does the STD725 use HART? Yes, it provides two-wire 4 to 20 mA with HART 7 digital communication and a choice of Honeywell standard or NAMUR NE 43 failure levels.
Which housing and ingress rating does the STD725 have? The standard housing is powder-coated low-copper aluminium rated Type 4X, IP66 and IP67, with an all-stainless housing as an option.
How is the STD725 different from the STD735? The STD725 spans 400 inH2O while the STD735 spans 100 psi, so the STD725 suits low differentials and the STD735 suits higher-pressure lines.
Documents and quotation
The Honeywell STD700 specification (34-ST-03-121) lists the STD725 range limits, accuracy formulas, approvals and dimensional drawings, and we can share it with your RFQ.
To request a quotation for Honeywell STD725, send the part number, required quantity, calibrated range, output option and hazardous area approval to Seven Star LLC. We will confirm availability and lead time.
Other Models in the STD700 Range
Seven Star LLC supplies models from the STD700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STD725 SmartLine STD700 Differential Pressure Transmitter | Pressure Transmitters | You are viewing this model |
| Honeywell STD735 SmartLine STD700 Differential Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STD775 SmartLine STD700 High Range DP Transmitter | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Honeywell STD725 SmartLine STD700 Differential Pressure Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STD725 SmartLine STD700 Differential
Answers from our engineering team on installation, compatibility and integration.
01What range does the Honeywell STD725 cover?
The STD725 covers plus or minus 400 inH2O (plus or minus 1000 mbar) with a minimum span of 4 inH2O (10 mbar), giving up to 100:1 turndown.
02What is the accuracy of the STD725?
Reference accuracy is up to 0.05 percent of span with stability of 0.020 percent of URL per year over ten years, from the STD700 datasheet.
03Does the STD725 use HART?
Yes, it provides two-wire 4 to 20 mA with HART 7 digital communication and a choice of Honeywell standard or NAMUR NE 43 failure levels.
04Which housing and ingress rating does the STD725 have?
The standard housing is powder-coated low-copper aluminium rated Type 4X, IP66 and IP67, with an all-stainless housing as an option.
05How is the STD725 different from the STD735?
The STD725 spans 400 inH2O while the STD735 spans 100 psi, so the STD725 suits low differentials and the STD735 suits higher-pressure lines.


















Reviews