Brand: Yokogawa
Yokogawa SC450G-A-U FM Conductivity Converter
Description
Why SC450G-A-U exists
Plants that follow North American area-classification rules cannot always install a general purpose analyser converter next to the process. Yokogawa SC450G-A-U answers that gap. It is the AC-powered EXAxt 450 conductivity and resistivity converter with the FM U type, meaning it holds FM nonincendive approval for Class I, Division 2, Groups A to D, T6 within -20 to 55 C ambient.
For Gulf projects that were engineered by US or Canadian contractors, the U type often appears in the instrument index because the specification quotes Division 2. SC450G-A-U is therefore a typical RFQ line from EPC bid lists, and it is the exact orderable string rather than a generic converter name.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Reading the SC450G-A-U code
- SC450G is the converter family for conductivity and resistivity measurement.
- A is the power code: AC supply, 100 to 240 V AC.
- U is the type code: FM version, nonincendive.
- No option is part of the base code, so mounting, awning hood or tag plate are written as slash options where allowed.
SC450G-A-U performance and electrical data
| Parameter | Value |
|---|---|
| Approval | FM3611 Class I, Div. 2, Groups A, B, C, D, T6, Ta -20 to 55 C |
| Supply | 90 to 264 V AC, ratings 100 to 240 V AC, 50 or 60 Hz plus or minus 5 percent, 15 VA |
| Input | Two- or four-electrode, square wave, cell constant 0.005 to 50.0 per cm, 60 m maximum cable |
| Conductivity range | 0.000 uS/cm to 2000 mS/cm |
| Accuracy | 0.5 percent of reading; temperature 0.3 C; mA tolerance 0.02 mA |
| Outputs | 2 x 4-20 mA with HART 5; 4 x SPDT relays 250 V AC 5 A |
| Burn-out | 21.0 mA up or 3.6 mA down per NAMUR NE43 |
| Housing | Cast aluminium, IP66 / NEMA 4X / CSA Type 3S, 144 x 144 mm, about 1.5 kg |
| EMC / safety | EN 61326-1 Class A, EN 61010-1, UL 61010-1, CAN/CSA C22.2 No. 61010-1 |
| Altitude | 2000 m or less |
How SC450G-A-U differs from SC450G-A-A and SC450G-D-U
Three numbers separate the neighbours. First, the approval: SC450G-A-U adds the FM nonincendive Division 2 rating that SC450G-A-A lacks. Second, the closure of cable entries: plugs in NEMA 4X form versus IP66 glands. Third, the option list, because six options are barred on the U type. Compared with SC450G-D-U, the difference is again power: 15 VA at 100 to 240 V AC against 10 W at 12 to 24 V DC.
The measurement electronics are not altered by the U type, so accuracy, compensation tables and the touchscreen behave exactly as on the general purpose unit.
Operating interface and measuring functions
Although the label is about area classification, most of the day-to-day value of SC450G-A-U is in how the converter is operated. The touch display shows the primary variable in large digits, the secondary variables in small digits, the tag number, the process description and the status of the contact outputs. A trend page can be set anywhere between 15 minutes and 2 weeks, and the zoom view reports average, maximum and minimum values of the interval. Eight languages are built in: English, French, German, Italian, Spanish, Swedish, Portuguese and Japanese.
On the measurement side the converter offers cell fouling monitoring, temperature compensation by the NaCl table of IEC 60746-3 or by two user coefficients, and matrix compensation with 13 stored matrices and 2 user matrices of 100 points each. Steam, condensate and boiler-water functions include cation, ammonia and morpholine conductivity, and the USP chapter 645 behaviour is implemented for pharmaceutical water. Calibration is semi-automatic against OIML KCl buffer tables with a stability check, or manual to a grab sample.
Control functions deserve a mention for classified areas, because the relays can run PID duty-cycle or pulse-frequency control to a dosing pump while the HART signal on mA1 carries up to four process variables to an asset-management system such as PRM or AMS. The fail-safe contact is S4, and the hold function freezes outputs during maintenance.
Applications in Oman and GCC facilities
SC450G-A-U is chosen where the instrument specification mentions FM Division 2: gas processing trains, tank-farm water-treatment areas, and utility blocks built to American standards. The conductivity measurement itself serves boiler feedwater, condensate polishing, demineralised plant outlets and cooling water. Because the converter is rated T6, surface temperature stays low enough for most Division 2 gases, which suits many classified-area spec sheets in oil and gas projects.
Selection and installation
For Division 2 locations you must follow the local code and the control drawing supplied with the product; this page does not replace the instruction manual. Fit conduit or glands that meet your code in place of the plugs. Because /U, /PM and /H5 are not offered, plan a mounting method with /UM, or fabricate your own plate. During commissioning, configure the cell constant and temperature element first, then calibrate with the OIML KCl tables, and finally set relays and the HART variables.
Keep the cover closed when the unit is energised; the label on the housing says do not open when energised.
Maintenance notes
Maintenance consists of sensor cleaning and calibration records in the logbook. Replace plugs if damaged so the NEMA 4X claim is preserved. Do not modify the unit in the field, since that could void the area approval. Keep a record of the serial number and the approval label alongside the loop drawing, because inspectors in classified areas ask for it, and store spare plugs with the instrument kit so that an opened entry can be closed again without delay during a shutdown. Verify the supply fuse rating and the earth connection at every planned inspection as well.
Documents and quotation
The datasheet for SC450G-A-U is attached. Please send an RFQ to Seven Star LLC with SC450G-A-U, the quantity, the area classification and the delivery location so we can reply with availability.
Other Models in the SC450G Range
Seven Star LLC supplies models from the SC450G range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa SC450G-A-A Conductivity Converter, AC | Liquid Analytical Systems | View details |
| Yokogawa SC450G-D-A Conductivity Converter, 24 V DC | Liquid Analytical Systems | View details |
| Yokogawa SC450G-A-U FM Conductivity Converter | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Yokogawa SC450G-A-U FM Conductivity Converter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa SC450G-A-U FM Conductivity Converter
Answers from our engineering team on installation, compatibility and integration.
01What approval does SC450G-A-U carry?
The U type has FM nonincendive approval to FM3611: Class I, Division 2, Groups A, B, C and D, temperature class T6, for ambient temperatures from -20 to 55 C.
02Which options are not available with SC450G-A-U?
The datasheet states that /U pipe and wall hardware, /PM panel hardware, /H5 awning hood and the /AFTG, /ANSI and /AM20 conduit adapters are not specified for the FM U version. /UM universal kit and /SCT tag plate remain.
03How are unused cable entries closed on SC450G-A-U?
NEMA 4X close-up plugs are mounted in the unused entries and can be replaced with conduit fittings as required, whereas the general purpose type receives IP66 cable glands.
04Does the FM label make SC450G-A-U intrinsically safe?
No. The listing is nonincendive for Class I, Division 2 only, which the datasheet notes as nonincendive for FM only. It does not certify the converter for Zone 0 or Division 1 service.
05What supply does SC450G-A-U need?
The A power code means 100 to 240 V AC, acceptable 90 to 264 V AC, 50 or 60 Hz within 5 percent, consuming about 15 VA. A 12 to 24 V DC unit would be SC450G-D-U.