Brand: Honeywell
Honeywell STA77S ST 700 In-Line Absolute Transmitter, 3000 psia
Description
The Honeywell STA77S in-line absolute transmitter for pressures up to 3000 psia
Honeywell offers one 3000 psia absolute transmitter in the ST 700 line, the STA77S. It is an in-line device: instead of a dual-head body with a bracket, the sensing module has a single threaded process connection and a compact stainless body that weighs 3.6 lb (1.6 kg) with an aluminium housing. Range is 0 to 3000 psia (210 barA), minimum span is 30 psia (2.1 barA), and the maximum turndown is 100:1. Output is 4 to 20 mA with HART 7.
Applications that need this combination include high-pressure gas storage, injection and compression, hydraulic systems, and test benches. A low weight and a single connection also make the STA77S a convenient choice where space is tight, for example inside an analyser cabinet or a skid-mounted package.
STA77S parameters
| Parameter | Value |
|---|---|
| Upper range limit | 3000 psia (210 barA) |
| Lower range limit | 0 psia |
| Minimum span | 30 psia (2.1 barA) |
| Maximum turndown | 100:1 |
| Reference accuracy | 0.065 percent of span |
| Stability | 0.02 percent of URL per year, 10 years |
| Reference turndown | 5:1 |
| Breakpoint span C | 600 psia (42 barA) |
| Total performance example | 0.163 percent of span at 600 psia |
| MAWP | 3,000 psia (210 barA) |
| No-burst rule | 2.5 times MAWP plus 1,000 psi |
| Barrier diaphragm and process head | 316L stainless steel or Hastelloy C-276 |
| Connections | Half-inch NPT female, half-inch NPT male, 9/16 Aminco, G half-B male |
| Fill fluid | Silicone 200 or CTFE |
| Weight | 3.6 lb (1.6 kg), aluminium housing |
| Response time | 100 ms |
Where STA77S sits in the ST 700 absolute range
Two features separate the STA77S from the STA745 and STA725. The first is range: 3000 psia against 500 psia and 780 mmHgA. The second is the reference turndown of 5:1, much lower than the 16.7:1 of the STA745, which means that accuracy starts to degrade once the span is below 600 psia (42 barA), one-fifth of the upper range. At a 600 psia span the datasheet gives total performance of 0.163 percent of span.
Compared with the ST 800 in-line equivalent, the STA87L, the STA77S has lower accuracy (0.065 against 0.030 percent standard), a lower maximum turndown (100:1 against 200:1) and HART-only communications, but the same 3000 psia upper limit and the same in-line body style.
Installing the STA77S safely
Select the thread to suit the pipework. For 9/16 Aminco, ensure that the tubing end is cone-and-thread matched. Support the body when a long unsupported tube is used. The STA77S has no vent or drain valve, so any bleeding must be done upstream. Because a pressurised system at 3000 psia stores a great deal of energy, relieve and drain the line before removing the transmitter.
After commissioning, use the HART interface to read the digital process variable, which is the most accurate representation of the sensor measurement, and verify the 4 and 20 mA output with a milliammeter.
Absolute or gauge: is the STA77S the right choice?
At 3000 psia the difference between absolute and gauge reference is about 14.7 psi, which is under 0.5 percent of the range. Many engineers therefore choose a gauge transmitter for high-pressure duty. The STA77S is the better choice when the same transmitter will also see low pressures during evacuation or start-up, when the process is calculated on an absolute basis such as gas density or compressibility, or when the loop is tied to a site that does not want weather-driven barometric movement in the reading.
If your service is purely high pressure with a vented, atmospheric reference, ask us about the ST 700 gauge alternatives such as the STG77S so that you can compare ranges and accuracy side by side.
Uses in oil, gas, water and industry
Oilfield gas-lift manifolds and injection skids, compressed-natural-gas fuelling, hydrogen and nitrogen storage, high-pressure cleaning and descaling units, and hydraulic power packs are all good fits. In water and desalination plants the device can monitor high-pressure reverse-osmosis feed at the lower end of its range.
Pressure-spike protection and safety notes for STA77S
High-pressure absolute service often involves fast transients from pumps, compressors and valve closures. Overpressure is allowed to 1.5 times MAWP, which is 4,500 psia for this model, and the no-burst rule of 2.5 times MAWP plus 1,000 psi applies above 2,000 psi MAWP. Nevertheless, repeated spikes shorten diaphragm life and move calibration, so use a needle valve or snubber on pulsating lines and set damping to suit.
The integral dual-seal design follows ANSI/NFPA 70 and ANSI/ISA 12.27.0, and the family is documented for SIL 2/3 applications. A lightning-protection terminal block with a 5000 A impulse rating at 8/20 microseconds is optional for exposed sites.
Wiring accepts conductors up to 16 AWG and is polarity insensitive. If the plant uses intrinsically safe barriers, remember that the loop supply is limited to 30 VDC and the load can be 0 to 1,440 ohms, so check the barrier voltage drop.
Calibration and service of STA77S
Verify calibration every two years. Replace the display, electronics or sensor module without disturbing agency approvals except in flameproof installations. An optional four-year extended warranty is offered in the datasheet. If the STA77S sees repeated pressure spikes, add a snubber to protect the sensor.
Ordering the STA77S
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For the STA77S supply the thread type, housing, display, approvals and options such as lightning protection.
Documents and quotation
The Honeywell STA700 specification 34-ST-03-120 is attached as the datasheet for the STA77S. Send an RFQ with the part number STA77S, the quantity and delivery location, and we will respond with availability and lead time.
Ordering Checklist for the Honeywell STA77S
Before you ask for a quotation for the Honeywell STA77S, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the pressure transmitters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Other Models in the Honeywell Sta700 Range
Seven Star LLC supplies models from the Honeywell Sta700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STA745 SmartLine ST 700 Absolute Transmitter, 500 psia | Pressure Transmitters | View details |
| Honeywell STA725 SmartLine ST 700 Absolute Pressure Transmitter | Pressure Transmitters | View details |
| Honeywell STA77S ST 700 In-Line Absolute Transmitter, 3000 psia | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell STA77S ST 700 In-Line Absolute Transmitter, 3000 psia Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STA77S ST 700 In-Line Absolute
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STA77S?
0 to 3000 psia (0 to 210 barA) with a 30 psia (2.1 barA) minimum span and turndown up to 100:1.
02How does the STA77S differ from the STA87L?
The STA87L is the ST 800 equivalent with 0.030 percent accuracy, 200:1 turndown and multiple protocols; the STA77S is HART-only with 0.065 percent accuracy and 100:1 turndown.
03What thread options does the STA77S have?
Half-inch NPT female, half-inch NPT male, 9/16 Aminco and G half-B male threaded fittings.
04What are the wetted materials of the STA77S?
The barrier diaphragm and process head are 316L stainless steel or Hastelloy C-276.
05What is the weight of the STA77S?
About 3.6 lb (1.6 kg) with an aluminium housing, much lighter than the 3.8 kg dual-head STA700 models.


















Reviews
There are no reviews yet.