Brand: Danfoss
Danfoss 017-152066 RT 17 Room Thermostat -50 to -15 C
Description
Danfoss 017-152066 RT 17 room thermostat for -50 to -15 °C
The Danfoss 017-152066 is an RT 17, a thermostat with a built-in room (air) sensor for deep-freeze temperatures between -50 and -15 °C. The sensor is a finned element that projects below the housing, so no capillary or pocket is required: the whole unit mounts in the cold air space or on a wall near it. The differential is adjustable between 2.2 and 7 °C at the lowest range setting and between 1.5 and 5 °C at the highest setting, and the sensor tolerates 100 °C. Seven Star LLC supplies the 017-152066 in Oman and the GCC as an independent supplier in Muscat.
The Danfoss product page lists 017-511766 as the identical product, and that code appears in the data sheet ordering table.
What 017-152066 and RT 17 mean
| Element | Meaning |
|---|---|
| RT 17 | Thermostat with room sensor, range -50 to -15 °C, vapour charge |
| 017-152066 | Danfoss code number of this version; identical to 017-511766 |
| Room sensor | Finned air sensor integrated in the housing, no capillary tube |
| SPDT | Single-pole changeover contact for cooling control or alarm |
017-152066 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Danfoss 017-152066 (RT 17) |
| Setting range | -50 to -15 °C (-58 to 5 °F) |
| Differential at lowest range setting | 2.2 to 7 °C, adjustable |
| Differential at highest range setting | 1.5 to 5 °C, adjustable |
| Sensor type | Room sensor |
| Maximum sensor temperature | 100 °C (212 °F) |
| Charge | Vapour |
| Reset | Automatic |
| Contact system | Single-pole changeover (SPDT) |
| Contact rating | AC-1 10 A 400 V; AC-3 4 A 400 V; AC-15 3 A 400 V; DC-13 12 W 220 V |
| Cable entry | 2 x Pg 13.5 for 6 to 14 mm cable |
| Enclosure | IP66 (IP54 on versions with external reset); bakelite housing, polyamide cover |
| Ambient temperature | -50 to 70 °C |
| Net weight | 0.798 kg |
| Approvals listed for this code | CCC, CE, EAC, LVD, RoHS, UA |
| Packing | Industrial pack of 12 |
Room sensor behaviour and placement
A room-sensor thermostat measures the temperature of the air around the housing sensor, so its position governs accuracy. Mount it away from evaporator discharge air, door openings and direct radiation, and where air circulates freely around the finned element. In deep freezers the warm element is the housing, which must still stay above the minimum ambient temperature of -50 °C; the data sheet states -50 to 70 °C for the thermostat housing. The vapour charge works only when the sensor is the coldest component, and here the sensor sits in the cold air while the housing and its bellows are at similar or higher temperature, which is consistent with the manufacturer rule for type A units.
The differential determines the temperature swing of the stored goods. A narrow setting such as 2 °C near the top of the range gives tight control but risks short cycling in a small cold room; a wider setting reduces compressor starts. Set the differential on the disc and verify with a reference thermometer, since the mechanical differential is smaller than the thermal one the system experiences.
Place of the 017-152066 in the RT thermostat family
For capillary-sensor duty in similar ranges the RT 9 covers -45 to -15 °C and the RT 13 covers -30 to 0 °C, both with 2 m of capillary. The RT 3 (017-501466) covers -25 to 15 °C with a remote bulb. Only the RT 17 offers the integral room sensor for the -50 °C region. If the air space is large and the sensor must reach into a duct or through an insulated wall, a capillary type is the easier fit.
Selection and ordering checklist for RT 17
- Minimum and maximum air temperature required, within -50 to -15 °C.
- Differential needed to avoid short cycling at the chosen setting.
- Position where the housing can be mounted and sensor exposed to representative air.
- Switching function and load: SPDT contact 10 A 400 V AC-1, 3 A 400 V AC-15.
- Required approvals; this code lists CE, EAC, CCC and UA but no marine class marks.
- Quantity and spare units for service.
Cold-range thermostats compared with the 017-152066
| Type | Code | Range °C | Sensor | Max sensor °C | Differential at highest / lowest setting °C |
|---|---|---|---|---|---|
| RT 17 | 017-152066 | -50 to -15 | Room sensor | 100 | 1.5 to 5 / 2.2 to 7 |
| RT 9 | 017-506666 | -45 to -15 | Remote bulb, 2 m | 150 | 1 to 4.5 / 2.2 to 10 |
| RT 13 | 017-509766 | -30 to 0 | Remote bulb, 2 m | 150 | 1 to 3 / 1.5 to 6 |
| RT 3 | 017-501466 | -25 to 15 | Remote bulb, 2 m | 150 | 1 to 4 / 2.8 to 10 |
The table shows why the RT 17 is chosen mostly for room-air control: it is the only member that reaches -50 °C and the only one with a built-in air sensor, at the cost of a lower sensor temperature limit of 100 °C. During defrost cycles the air near an evaporator can exceed the set range, which the sensor tolerates without damage.
Installation and commissioning
Use the two fixing holes behind the cover and keep the cable entry downward on vibrating or wet sites. Seal both Pg 13.5 glands, since moisture condenses quickly on equipment that is below freezing, and keep drip loops on the wiring. After connecting the SPDT contact, cycle the unit with a test sensor temperature, if available, or confirm the cut-out against a calibrated thermometer.
Applications of the 017-152066 in Oman and the GCC
Deep-freeze rooms for food distribution, blast freezers, pharmaceutical cold chains and medical storage are the typical uses. Oman’s high ambient temperature raises the load on freezer plants, so a robust, adjustable thermostat that can tolerate the housing at up to 70 °C is helpful in plant rooms and unconditioned loading bays.
Information to send with an RFQ for 017-152066
- Code 017-152066 and quantity.
- Target temperature, differential and the space size.
- Mounting location and cable entry arrangement.
- Electrical load.
- Required approvals.
Documents and quotation
The Danfoss RT thermostat data sheet is attached on this page.
Send the code 017-152066 and your temperature requirement and we will confirm availability and a quotation for Oman and the GCC.
Other Models in the Danfoss Rt Thermostat Range
Seven Star LLC supplies models from the Danfoss Rt Thermostat range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Danfoss 017-501466 RT 3 Thermostat -25 to 15 C | Temperature Instrumentation | View details |
| Danfoss 017-152066 RT 17 Room Thermostat -50 to -15 C | Temperature Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet Danfoss 017-152066 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss 017-152066 RT 17 Room Thermostat -50 to -15
Answers from our engineering team on installation, compatibility and integration.
01What range does the Danfoss 017-152066 cover?
The RT 17 covers -50 to -15 degrees C with an adjustable differential of 2.2 to 7 degrees C at the lowest and 1.5 to 5 degrees C at the highest setting.
02Does the RT 17 have a capillary tube?
No. It has a room (air) sensor built into the housing, so no capillary or sensor pocket is needed.
03What is the maximum sensor temperature?
100 degrees C (212 degrees F).
04What is the identical product code?
The Danfoss product page lists 017-511766 as identical to 017-152066.
05What contact and enclosure does it have?
An SPDT contact rated AC-1 10 A 400 V in an IP66 housing with two Pg 13.5 cable entries.