Brand: Danfoss
Danfoss 017-140866 RT 5 Pressure Switch 4-17 bar
Description
Danfoss 017-140866 RT 5 pressure switch, 4 to 17 bar
The Danfoss 017-140866 is an RT 5, a mechanical pressure switch for the medium-pressure band from 4 to 17 bar g with an adjustable differential of 1.2 to 4 bar. It is built like the other RT switches around a bellows, a set spring and an SPDT snap contact in an IP66 housing, and this code is supplied with a weld nipple for a 6.5/10 mm tube. Its working pressure is 22 bar g and test pressure 25 bar g, so there is a comfortable margin above the 17 bar top of scale. Seven Star LLC supplies the 017-140866 in Oman and the GCC as an independent supplier in Muscat.
The manufacturer lists 017-525566 as the identical product on its product page.
017-140866 identification and options
| Element | Meaning |
|---|---|
| RT 5 | Pressure type, regulation 4 to 17 bar g, differential 1.2 to 4 bar |
| 017-140866 | Danfoss code number, G 3/8 male connection with weld nipple d 6.5 / D 10 mm |
| RT 5A | Related version of the same range with manual maximum reset (for example 017-504766 per the ordering table) |
| RT 5AL | Neutral-zone version of the same range for floating control |
017-140866 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Danfoss 017-140866 (RT 5) |
| Regulation range | 4 to 17 bar g (58 to 246.6 psig) |
| Differential | 1.2 to 4 bar adjustable (17.4 to 58 psi) |
| Maximum working pressure | 22 bar g (320 psig) |
| Maximum test pressure | 25 bar g (363 psig) |
| Pressure element | Bellows |
| Pressure connection | G 3/8 male, ISO 228-1, with weld nipple d 6.5 / D 10 mm |
| Reset | Automatic |
| Contact system | Single-pole changeover (SPDT), snap action |
| Contact rating | AC-1 10 A 400 V; AC-3 4 A 400 V; AC-15 3 A 400 V; DC-13 12 W 220 V |
| Cable entry | 2 x Pg 13.5 for 6 to 14 mm cable |
| Enclosure | IP66 (IP54 on versions with external reset) |
| Ambient temperature | -50 to 70 °C |
| Terminal wiring | 0.2 to 2.5 mm² solid or flexible; 0.2 to 1.5 mm² with ferrules; tightening torque max 1.5 Nm |
| Net weight | 0.79 kg |
| Approvals listed for this code | BV, CCC, CE, CMIM, EAC, GL, KR, LR, LVD, NKK, RINA, RoHS, TYSK, UA |
| Packing | Industrial pack of 12 |
Choosing set point and differential
For a compressor or pump control the lower knob value is the cut-in pressure and the differential disc adds the pressure span before cut-out. A typical air system running between 6 and 8 bar needs a set point of 6 bar and a differential of 2 bar, comfortably inside the 1.2 to 4 bar differential range of the RT 5. Too small a differential causes short cycling and hunting; too large a differential gives large pressure swings. The manufacturer recommends fine-tuning the mechanical differential after the plant has run for a while, because the thermal and hydraulic response of the real system always adds to it.
The 017-140866 is supplied with a weld nipple for a 6.5/10 mm tube. If the tube connection will be disturbed often for service, a code with a cutting-ring connection (for example in the same RT 5 ordering table) may be easier to maintain.
Where the RT 5 fits in the RT range
The RT 5 covers 4 to 17 bar, overlapping the top of the RT 116 (1 to 10 bar, 017-140166) and the bottom of the RT 117 (10 to 30 bar). For a system with a normal operating pressure around 8 to 12 bar, either an RT 116 or an RT 5 can work, but the RT 5 keeps the set point in the middle of the scale for pressures from 8 to 14 bar. For fail-safe functions, the RT 6 and RT 30 families have double bellows and EN 12263 approval, which the RT 5 does not.
Selection and ordering checklist for RT 5
- Cut-in and cut-out pressures within 4 to 17 bar and the differential between them.
- Highest system or relief pressure, kept below 22 bar g working and 25 bar g test.
- Connection type: weld nipple on this code, or other code numbers with G 3/8 male only or a cutting ring.
- Medium and temperature; the general media window in the data sheet is -50 to 100 °C, and steam needs a water-filled loop.
- Electrical load against contact ratings.
- Class approvals; this code lists BV, GL, KR, LR, NKK and RINA among others.
Installation and maintenance
Fit the switch to a rigid panel or bracket using the two fixing holes under the cover, and keep the cable entries facing downwards on vibrating plant. On steam, insert a water-filled loop; on cold-water lines where frost is possible, let the switch operate on an air cushion to avoid bursting a water-filled element. Pulsating lines need a damping coil. Replace the contact system or the complete switch if the contact has been overloaded; the contact sets are separate parts in the accessories list.
Applications of the 017-140866 in Oman and the GCC
Instrument and service air receivers, cooling-water and chilled-water circuits, boiler feed and fuel-oil systems, refrigeration high-pressure sides and fire-water jockey pump control are the typical applications. In Oman the RT 5 is often seen on marine and offshore utility skids because of its class approvals, and on onshore skids where a robust switch without electronics is preferred in dusty, hot, humid conditions.
Information to send with an RFQ for 017-140866
- Code 017-140866 and quantity.
- Required cut-in and cut-out pressures.
- Medium, temperature and pulsation.
- Connection style and weld nipple requirement.
- Electrical load, voltage and approvals.
Site conditions in Oman for the 017-140866
Field instruments in Oman are exposed to strong sun, high ambient temperature, wind-blown dust and, on coastal plants, salt in the air. When you specify the 017-140866, check the ambient and process temperature limits, the enclosure rating and the wetted and housing materials against the actual installation point, and consider sunshades for transmitters mounted in direct sunlight. Cable entries should be sealed with suitable glands so that dust and moisture cannot enter the housing.
Calibration and verification planning matters as much as selection. Record the range, configuration and tag data of each 017-140866 at commissioning, define a check interval that suits the criticality of the loop, and keep the certificates with the plant documentation so that audits and shutdown work can proceed without delay.
Documents and quotation
The Danfoss RT pressure switch data sheet is attached on this page, with ordering tables, material list and setting notes.
Send the code 017-140866 and your set points and we will confirm availability and a quotation for Oman and the GCC.
Other Models in the Danfoss Rt Pressure Switch Range
Seven Star LLC supplies models from the Danfoss Rt Pressure Switch range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Danfoss 017-140166 RT 116 Pressure Switch 1-10 bar | Pressure Instrumentation | View details |
| Danfoss 017-140766 RT 121 Vacuum Pressure Switch | Pressure Instrumentation | View details |
| Danfoss 017-140866 RT 5 Pressure Switch 4-17 bar | Pressure Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet Danfoss 017-140866 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss 017-140866 RT 5 Pressure Switch 4-17 bar
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Danfoss 017-140866?
The RT 5 covers 4 to 17 bar g with an adjustable differential of 1.2 to 4 bar.
02What are its working and test pressures?
The maximum working pressure is 22 bar g and the maximum test pressure is 25 bar g.
03What connection does this code have?
A G 3/8 male thread to ISO 228-1 with a weld nipple of d 6.5 / D 10 mm.
04What contact and enclosure does it have?
An SPDT snap-action contact rated AC-1 10 A 400 V, in an IP66 housing with two Pg 13.5 cable entries.
05Which approvals does the product page list?
BV, CCC, CE, CMIM, EAC, GL, KR, LR, LVD, NKK, RINA, RoHS, TYSK and UA are listed for code 017-140866.