Brand: Endress+Hauser (E & H)
Endress+Hauser FMD72 Deltabar Metallic Electronic dP
Description
FMD72 electronic differential pressure with metallic process membranes
The Endress+Hauser FMD72 applies the electronic differential pressure idea of the Deltabar FMD7x line to media where a metal diaphragm is the better choice. Two sensor modules are mounted at the lower and upper tapping points of a vessel, each with its own fully welded stainless steel membrane and a small silicone oil fill, and a single transmitter combines their digital signals into a level, volume or mass value. Output is 4–20 mA with superimposed HART. Seven Star LLC supplies the FMD72 in Oman and the GCC as an independent supplier in Muscat, and can match the sensor ranges and connections to your tanks.
Compared with the ceramic FMD71, the FMD72 starts at the 400 mbar cell, tolerates lower process temperatures and offers more flush and hygienic connection styles. The membrane is AISI 316L (1.4435) as standard, with Alloy C available on request.
Endress+Hauser FMD72 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser FMD72 (Deltabar FMD72, electronic differential pressure, HART) |
| Sensor principle | Metallic process membrane, silicone oil transfer to a semiconductor Wheatstone bridge |
| Process membrane | AISI 316L (1.4435); Alloy C on request |
| Sensor ranges | 400 mbar, 1, 2, 4, 10 and 40 bar (6 to 600 psi); absolute cells from 1 bar |
| Maximum overpressure (OPL) | Up to 160 bar (2,400 psi) on the 40 bar cell; MWP 100 bar |
| Output signal | 4–20 mA with HART 6.0, two-wire |
| Supply voltage | 13 to 45 V DC (test jumper in Test position) or 12 to 45 V DC (Non-test), non-hazardous area |
| Reference accuracy | ±0.15 % of URL for the 400 mbar cell; ±0.075 % standard and ±0.05 % Platinum from 1 bar; hygienic connections: wider values |
| Process temperature | Internal membrane connections −40 to +125 °C; flush connections −40 to +100 °C; hygienic flush −40 to +130 °C (150 °C for max. 60 min) |
| Vacuum resistance | 0.01 bar abs (0.15 psi abs) with silicone oil under reference conditions |
| Ambient temperature | −40 to +80 °C without display; −20 to +70 °C with display |
| Degree of protection | IP66/68, NEMA 4x/6P |
| Thermal effect (1 bar and above) | ±0.101 % of URL per sensor between −10 and +60 °C |
| Housings | Transmitter T14 aluminium or stainless, T17 316L; sensor housing aluminium or stainless |
How the FMD72 sensors and transmitter work together
When process pressure deflects the metal membrane, the oil behind it carries the force to a silicon measuring element with a Wheatstone bridge. Each sensor module converts the bridge voltage to a digital value. The sensors are separate from the transmitter, so there is no capillary and no oil-filled line between the two tapping points. That removes the temperature-driven error that long capillaries add to conventional diaphragm seal systems, which the manufacturer lists as a main advantage of the design.
The transmitter reads the HP sensor (hydrostatic plus head pressure) and the LP sensor (head pressure only), subtracts them and applies the level, volume or mass calculation. It reports both pressures, both sensor temperatures and the electronics temperature through HART, which is helpful when you need to separate a process change from a sensor fault.
FMD72 sensor ranges and overload limits
| Sensor | URL (gauge) | MWP | OPL | Code gauge / abs |
|---|---|---|---|---|
| 400 mbar | +0.4 bar | 4 bar | 6 bar | 1F / – |
| 1 bar | +1 bar | 6.7 bar | 10 bar | 1H / 2H |
| 2 bar | +2 bar | 13.3 bar | 20 bar | 1K / 2K |
| 4 bar | +4 bar | 18.7 bar | 28 bar | 1M / 2M |
| 10 bar | +10 bar | 26.7 bar | 40 bar | 1P / 2P |
| 40 bar | +40 bar | 100 bar | 160 bar | 1S / 2S |
The maximum differential span equals the URL of the HP sensor. Because the HP module in a closed vessel carries head pressure on top of the hydrostatic load, size it with that sum in mind. The datasheet recommends keeping the ratio between level and head pressure at or below 1:10 to avoid large errors.
Where the FMD72 fits in the Deltabar family
Pick the FMD72 over the FMD71 when the medium attacks ceramic, when the process drops below −25 °C, or when a flush or hygienic metal connection is needed. Pick the FMD71 when the lowest ranges (100 and 250 mbar) or an oil-free ceramic cell are preferred. The FMD78 sits in another branch: a Deltabar S with two diaphragm seals joined by capillaries to a single transmitter, used where process temperatures reach 400 °C or where a remote seal is mandatory. All three produce a level or differential pressure signal, but their sensor concepts and ordering codes differ.
FMD72 selection and ordering checklist
- Gauge or absolute cells, with the HP range covering hydrostatic plus head pressure.
- Reference accuracy: standard (G) or Platinum (D); note that 400 mbar cells only offer the standard class.
- Process connection family: internal membrane thread, flush thread, flange, clamp or hygienic type, with the material the datasheet lists for it.
- Process temperature, which differs for internal, flush and hygienic membrane connections.
- Delta ferrite certificate (option KF) if a limited ferrite content is required; hygienic connections allow the tighter figure.
- Housing material and cable entry (M20, G½ or NPT½), plus hazardous-area approval from the Ex documentation.
- Optional test certificates such as 3.1 material, NACE MR0175, helium leak, pressure and PMI tests.
Installing, commissioning and maintaining the FMD72
Fit the HP sensor at the lower connection and the LP sensor above the highest level, then mount the transmitter on a wall or pipe with its bracket. Keep the cable between sensors and transmitter intact and shorten it only with the supplied kit. Allow flush connections to sit properly in the tapping so the membrane is not shielded by a dead leg.
Perform the position adjustment on the differential value after mounting, set the span and density, and check that the loop reads as expected using the 4–20 mA test terminal. Write protection can be set by switch, software or remotely. Later, compare the two sensor temperatures and pressures against expectation: a gap that should not exist points to blockage, plugging or a damaged membrane on one side.
FMD72 in Oman and GCC industries
Plants in Oman and the GCC use the FMD72 on pressurised and vacuum vessels, tall columns, chemical day tanks and process vessels that see strong sun and cold nights. The all-metal membrane copes with media that would be unsuitable for ceramic, and the flush connections reduce clogging with sticky or crystallising liquids. For hygiene-sensitive services such as food, beverage and water treatment, the hygienic flush connections and the delta ferrite option are relevant. The IP66/68 housing resists dust and humid coastal air.
Information to send with an FMD72 RFQ
- Medium, density and process temperature, including cleaning or sterilising cycles.
- Tank height between tappings, operating pressure and any vacuum.
- Sensor ranges for HP and LP, gauge or absolute.
- Connection type, nominal size, pressure rating and wetted material.
- Hazardous-area class, housing material and cable thread.
- Certificates and tag text required.
Documents and quotation
The Endress+Hauser Technical Information that covers the Deltabar FMD71 and FMD72 is attached on this page as a datasheet, including the range tables and connection data referred to here.
For a quotation on the FMD72, send the part number, the sensor ranges and the connection details. Seven Star LLC will confirm availability and delivery to Oman and the GCC.
Other Models in the Eh Deltabar Electronic Dp Range
Seven Star LLC supplies models from the Eh Deltabar Electronic Dp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser FMD71 Deltabar Electronic dP Transmitter | Pressure Instrumentation | View details |
| Endress+Hauser FMD72 Deltabar Metallic Electronic dP | Pressure Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser FMD72 Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMD72 Deltabar Metallic Electronic dP
Answers from our engineering team on installation, compatibility and integration.
01What membrane material does the FMD72 use?
The standard process membrane is AISI 316L (1.4435). Alloy C is available on request, and process connections come in stainless steel with some in Alloy C276.
02What sensor ranges are available for the FMD72?
Gauge cells are 400 mbar, 1, 2, 4, 10 and 40 bar. Absolute cells are 1, 2, 4, 10 and 40 bar. The differential span cannot exceed the URL of the HP sensor.
03What is the process temperature range of the FMD72?
Internal membrane connections run from −40 to +125 °C, flush connections from −40 to +100 °C, and hygienic flush versions from −40 to +130 °C with a 60-minute excursion to 150 °C.
04Does the FMD72 use capillaries?
No. Two compact sensor modules are cabled to the transmitter, so there are no oil-filled capillaries that add temperature error as in conventional diaphragm seal systems.
05Which communication does the FMD72 support?
It provides 4–20 mA with HART 6.0 on two wires, with burst mode and additional transmitter status supported, and exposes both sensor pressures and temperatures.