Brand:

Danfoss EV210BW Direct-Operated Drinking Water Solenoid Valve

Description

EV210BW direct-operated drinking water solenoid valve, DN 1.5 to 6

The Danfoss EV210BW is a small direct-operated 2/2-way solenoid valve with an Eco brass body and EPDM seals for drinking-water and neutral-liquid service. It opens at zero differential pressure, has connections from G1/8 to G3/8 and orifices from 1.5 to 6 mm, and works at differential pressures up to 10 bar depending on orifice and coil. Seven Star LLC supplies the EV210BW in Oman and the GCC as an independent supplier in Muscat; the sections below set out the ranges, pressure limits and checks needed before ordering.

EV210BW technical specifications

Parameter Specification
Manufacturer / part number Danfoss EV210BW (series; orifice 1.5, 2, 3, 4.5 and 6 mm)
Function 2/2-way, direct operated; NC (1.5–6 mm) and NO (1.5–4.5 mm)
Body material Eco brass
Connections G1/8, G1/4 and G3/8 (ISO 228/1)
Kv value 0.08, 0.15, 0.30, 0.55 and 0.70 m³/h for 1.5, 2, 3, 4.5 and 6 mm
Differential pressure 0 to 10 bar; minimum opening differential 0 bar
Working and test pressure Up to 10 bar and 15 bar
Seals EPDM, for drinking water
Media temperature −30 to 90 °C
Ambient temperature Up to 50 °C
Viscosity Up to 50 cSt

Pressure limits by orifice and coil

The datasheet gives the permitted differential pressure by orifice and coil type. NC valves with 1.5, 2 and 3 mm orifices run 0 to 10 bar on all listed AC and DC coils. The NC 4.5 mm orifice runs 0 to 10 bar on AC coils and 0 to 4.5 bar on BB/BE DC coils (0 to 9 bar on BG DC). The NC 6 mm orifice is limited to 0 to 4 bar on BB/BE AC and 0 to 2 bar on BB/BE DC, rising to 6 and 4.5 bar with BG coils. For NO valves, 1.5 and 2 mm remain at 10 bar, 3 mm drops to 5 bar and 4.5 mm to 2 bar. Always check the combination of orifice, function and coil.

How direct operation works

In the NC version a spring presses the valve plate on the orifice when the coil is off. Energising the coil lifts the armature and plate off the orifice and the valve opens regardless of pressure, so it operates at zero or even very low differential pressure; the datasheet gives an example of about 0.08 l/min through the 1.5 mm valve at only 10 mbar. The NO version is open when the coil is de-energised. Because the full force to move the plate comes from the coil, orifices are small and larger orifices are limited in pressure, as the table above shows.

Choosing between the EV210BW and larger valves

The EV210BW suits flows of a few litres per minute, coffee and beverage machines, dosing and water-treatment sampling. For higher flows in the same drinking-water family use the EV250BW with assisted lift (DN 10 to 22) or the servo-operated EV220BW (DN 15 to 50). For aggressive or dirty fluids, the EV212B with isolating diaphragm and stainless body is the appropriate step.

Coil options and power consumption

The valve body is ordered without a coil. The clip-on coils named in the datasheet include BB024AS (24 V, 50 Hz, 11 W, 19 VA, code 018F7358), BB230AS (220–230 V, 50 Hz, 11 W, 19 VA, code 018F7351), the DC coils BB012DS (12 V DC, 13 W, code 018F7396) and BB024DS (24 V DC, 16 W, code 018F7397), and the BE240CS coil (018F6783) with a −25 to 55 °C ambient range. The AC coils are rated for −40 to 80 °C ambient and the DC coils for −40 to 50 °C, so a hot enclosure favours AC coils.

Switching times

As a small direct-operated valve, the EV210BW opens in about 10 to 20 ms in the datasheet figures (indicative for water), which makes it suitable for short dosing pulses and fast filling cycles. Because the armature moves the plate directly, the valve also tolerates the frequent switching typical of dispensing equipment, provided the coil temperature stays inside its rating.

Selection and ordering checklist

  • Orifice size from the required flow and Kv value.
  • NC or NO function; NO is limited to 4.5 mm.
  • Differential pressure and coil type, checked against the table.
  • Connection thread G1/8, G1/4 or G3/8.
  • Coil voltage; clip-on BB, BE or BG coils.
  • Water quality and temperature up to 90 °C.

Installation, commissioning and maintenance

Fit a filter of around 50 mesh in front of the valve, mount at the permitted angle shown in the datasheet and follow the flow arrow. Exercise the valve at least every 24 hours in water service, keep water hardness at 6 to 18 °dH and conductivity at 50 to 800 µS/cm, and avoid stagnant warm water above 25 °C in the valve, as these measures limit scaling and dezincification. Treat the coil as hot during continuous operation.

Typical applications in Oman and the GCC

In the Gulf the valve appears in water dispensers, ice machines, small treatment skids, laboratory and sampling lines, humidifiers and cooling-water control on compact machines. Hard desalinated or mixed supply water makes the filter and exercise routine important, and ambient temperature near hot equipment should be kept under 50 °C.

Information to send with an RFQ

  • Orifice, connection and NC or NO function.
  • Coil voltage, frequency and AC or DC.
  • Pressure, flow and temperature.
  • Quantity and delivery location in Oman or the GCC.

Site conditions in Oman for the EV210BW

Valves and their accessories in Oman work in demanding conditions: high ambient temperatures, direct sun on outdoor pipe racks, dust, and corrosive coastal air at many oil, gas and water sites. When you specify the EV210BW, confirm the pressure and temperature ratings, body and trim materials and any sour-service or hazardous-area requirements against the actual line data, and check that seals and soft parts suit the process medium and the full temperature range.

For reliable operation, plan access for maintenance, define which spare parts are kept on site, and record the configuration of each installed EV210BW. Sending the complete process data sheet with your RFQ allows the selection to be checked before the order is placed.

Documents and quotation

A Danfoss datasheet for the EV210BW solenoid valve is attached on this page.

Send the orifice, function and coil data and we will confirm the matching valve.

Datasheets & Documents
  • PDF Datasheet Danfoss EV210BW Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss EV210BW Direct-Operated Drinking Water

Answers from our engineering team on installation, compatibility and integration.

01Does the EV210BW need a minimum pressure difference?
No. The minimum opening differential pressure is 0 bar, so it can operate at very low pressure.
02Which orifice sizes are available?
1.5, 2, 3, 4.5 and 6 mm for NC valves, and 1.5 to 4.5 mm for NO valves.
03What is the body material?
Eco brass with EPDM seals, intended for drinking water.
04What is the maximum working pressure?
Up to 10 bar, with the actual limit depending on orifice, function and coil.
05What media temperature is allowed?
Media temperature is -30 to 90 degrees C and ambient temperature up to 50 degrees C.