Brand: Endress+Hauser (E & H)
Endress+Hauser CA80TN Liquiline System Total Nitrogen Analyzer
Description
CA80TN Liquiline System total nitrogen analyzer from Endress+Hauser
The Endress+Hauser CA80TN is a colorimetric wet-chemical analyzer for the almost continuous determination of total nitrogen in liquid media, using digestion and UV photometry of the resulting nitrate. It is a member of the Liquiline System CA80 family: a cabinet analyzer with an integrated controller, a graphic display and optional digital Memosens sensor inputs. Seven Star LLC, an independent supplier in Muscat, supplies the CA80TN in Oman and the GCC, and this page explains what the analyzer measures, how it is configured and what to confirm before ordering.
Typical uses named in the manufacturer documentation: Monitoring of the wastewater treatment plant outlet, control of the water quality of surface waters, monitoring of industrial wastewater and control of industrial wastewater treatment.
CA80TN technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / CA80TN |
| Measured variable | Total nitrogen [mg/l, ppm] |
| Measuring range | CA80TN-**S5: 0 to 20 mg/l total-N; -**S6: 0 to 50 mg/l; -**S7: 0 to 250 mg/l |
| Maximum measured error | 0 to 20 mg/l: 0.1 mg/l or 3 %; 0 to 50: 0.25 mg/l or 3 %; 0 to 100: 1 mg/l or 3 %; 0 to 250: 4 mg/l or 5 % of measured value |
| Limit of detection | 0.06 mg/l N (undiluted range, laboratory conditions) |
| Repeatability | 0 to 20 mg/l: 0.04 mg/l or 2 %; 0 to 50: 0.1 mg/l or 2 %; 0 to 100: 0.4 mg/l or 3 %; 0 to 250: 2 mg/l or 5 % |
| Measuring interval | Continuous (approx. 55 min), adjustable 45 min to 24 h |
| Digestion time | 30 min, adjustable 15 to 120 min |
| Sample requirement | 32 ml without dilution module; 17 ml sample plus about 17 ml dilution water with it |
| Reagent requirement | RB 1.35 ml and RK 0.9 ml per measurement; a reagent set lasts about 3 months at a 1-hour interval |
| Calibration | Every 4 days; about 330 ml standard a month |
| Maintenance | Once weekly (visual check), about 1 hour a month |
| Supply / power | 100 to 120 V AC or 200 to 240 V AC, 50/60 Hz; 180 VA |
| Ambient temperature | +5 to +40 °C |
| Sample | 4 to 40 °C, low solids content, aqueous, homogenized |
| Degree of protection | IP55 / TYPE 3R (cabinet) |
How the CA80TN measures
The CA80TN converts the nitrogen compounds in the sample to nitrate by digestion and then measures nitrate by UV photometry, following the approach of the HJ636 standard. A pulsed long-life strobe lamp sends light through the cuvette; a beam splitter feeds a measuring detector and a reference detector, each behind a filter for its own wavelength. The reference signal is subtracted from the measuring signal and corrected by a factor that reduces the influence of turbidity.
The resulting difference is converted to total nitrogen. The documentation notes that this dependency is non-linear, which the analyzer handles internally. The digestion step is adjustable from 15 to 120 minutes, with a default of 30 minutes.
Controller, inputs, outputs and communication of the CA80TN
The analyzer is more than a single-parameter box. The controller supports one measuring channel for the analyzer itself plus, optionally, one to four digital Memosens sensor inputs (cable length up to 100 m), two passive 0/4 to 20 mA inputs and binary inputs. Outputs are two active 0/4 to 20 mA outputs as standard (four or six with additional modules), an alarm relay and optional extension relays. Fieldbus and network options are PROFIBUS DP, Modbus RS485, Modbus TCP, EtherNet/IP and PROFINET, and a web server gives browser access to configuration, measured values, diagnostics and logbooks. Alarm current follows NAMUR NE 43 with a factory failure current of 21.5 mA.
Data handling is thorough: ring or stack logbooks for analog values, events, calibration, hardware, versions, operations and diagnostics, with an SD card for software updates, configuration backup and logbook export. Up to six virtual process values can be calculated from the measured values and sent to an output or fieldbus. Configuration is possible from the front display, FieldCare, Field Data Manager software and the web server.
Where the CA80TN sits in the CA80 family
The CA80TN measures total nitrogen; ammonium is covered by the CA80AM and nitrite by the CA80NO within the same family. Together with the CA80TP for total phosphorus and the CA80COD for oxygen demand, it completes the nutrient and load profile at a wastewater outlet.
Because it digests the sample, the CA80TN has a measuring cycle of nearly an hour and calibrates every four days, which suits compliance and trend monitoring rather than fast loop control.
Selection and ordering checklist for the CA80TN
- Range code S5, S6 or S7 depending on expected total-N, and whether the dilution module is needed.
- Whether the sample can be taken directly or needs the optional Y strainer for particle-laden streams.
- Reagent supply for the RB and RK reagents and their storage.
- Cabinet or open version and the base or post option.
- Outputs, relays, fieldbus and optional Memosens inputs.
- Sampling point distance and height difference.
Installation, commissioning and maintenance of the CA80TN
The housing can be mounted on a wall, on a base (indoors only) or on a post accessory. The documentation asks you to protect the analyzer from additional heating, mechanical vibration and corrosive gases such as hydrogen sulfide, to keep it where air can circulate at the front, and to make sure the waste line drains freely without siphoning. Pay attention to the maximum height difference and distance to the sampling point, and keep the sample line short. Open versions without a door belong only in a closed room or protective cabinet.
After commissioning, calibration interval, cleaning and reagent exchange are set on the display. Weekly visual inspection and roughly one hour a month cover routine maintenance, with calibration every four days using about 330 ml of standard a month. Reagents last about three months at a one-hour interval. Counters monitor reagent, hoses and dispensers, and a leak sensor inside the housing and photometer temperature monitoring raise diagnostic messages, so keep spare hoses and reagent sets on site before they run out.
Typical CA80TN applications in Oman and the GCC
In Oman and the GCC the CA80TN is aimed at sewage treatment outlets, treated-effluent reuse schemes, industrial wastewater from food, fertilizer and petrochemical plants, and surface-water compliance points. A nitrogen-nutrient limit in a discharge permit is the usual reason to specify it. Place the cabinet in a ventilated shelter because the ambient limit is +5 to +40 °C.
Information to send with your CA80TN RFQ
- The full order code or the exact range and options needed (measuring range, dilution, cabinet or outdoor, hose heater, fieldbus).
- Sample description: temperature, solids, expected concentration and distance from the sampling point.
- Power supply (100 to 120 V AC, 200 to 240 V AC or 24 V DC where offered) and area ambient range.
- Required outputs, relays and fieldbus, plus any Memosens sensors to be connected.
- Reagent, standard and spare-part needs for the first year of operation.
Documents and quotation
The Endress+Hauser Technical Information for the CA80TN is attached on this page as a datasheet. Send the part number and your sample and site details, and we will confirm configuration, reagent supply, lead time and availability for Oman and the GCC.
Other Models in the Eh Liquiline Ca80 Range
Seven Star LLC supplies models from the Eh Liquiline Ca80 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CA80COD Liquiline System COD Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80PH Liquiline System Orthophosphate Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80TN Liquiline System Total Nitrogen Analyzer | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser CA80TN Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CA80TN Liquiline System Total
Answers from our engineering team on installation, compatibility and integration.
01What does the CA80TN measure?
It measures total nitrogen in aqueous samples by digestion followed by UV photometry of nitrate, in ranges up to 250 mg/l total-N.
02What ranges are available on the CA80TN?
Order code S5 covers 0 to 20 mg/l, S6 covers 0 to 50 mg/l and S7 covers 0 to 250 mg/l total nitrogen.
03How long does one CA80TN measurement take?
The measuring interval is continuous at about 55 minutes and adjustable from 45 minutes to 24 hours, with a default digestion time of 30 minutes.
04How often must the CA80TN be calibrated?
The documentation gives a calibration interval of 4 days, with a weekly visual check and about an hour of maintenance a month.
05Does the CA80TN need a Y strainer?