Brand:

Sitelab UVF-Trilogy PAHs Analyzer

Description

Overview

The Sitelab UVF-Trilogy PAHs Analyzer (Model No. 7200-004-PAHS) is a benchtop ultraviolet fluorescence instrument built to screen for polycyclic aromatic hydrocarbons across the C10–C22 carbon range, targeting the 16 EPA-regulated PAH compounds including benzo[a]pyrene. Seven Star LLC supplies the Sitelab UVF-Trilogy PAHs Analyzer to environmental laboratories, remediation contractors, and industrial site operators across Oman and the wider GCC region who need low-ppb PAH screening on soil and water samples without the multi-week turnaround of GC/MS confirmatory testing. Every Sitelab UVF-Trilogy PAHs Analyzer arrives factory calibrated using Sitelab’s own PAH reference standards, so laboratory staff and field technicians can generate quantitative results as soon as the unit is set up. With fast quotation turnaround and technical support, Seven Star LLC proudly supplies the Sitelab UVF-Trilogy across Oman and the wider GCC, backed by genuine stock, manufacturer-standard calibration data, and responsive local technical support.

Working Principle

The Sitelab UVF-Trilogy PAHs Analyzer excites a solvent-extracted sample with an ultraviolet LED tuned to the PAHS module’s specific wavelength and optical filter, measuring the fluorescence response of the aromatic ring structures characteristic of polycyclic aromatic hydrocarbons. The instrument achieves a minimum detection limit of 0.05 ppm, placing it in the low ppb detection range needed for regulatory PAH screening, and results from the Sitelab UVF-Trilogy PAHs Analyzer compare well to EPA Method 8270 and other GC/MS test methods as the sum of the 16 regulated PAH compounds, as well as the draft Method 8670 that has been circulated specifically for UVF-based PAH measurement. Because PAHs are combustion byproducts that persist strongly in soil and sediment, the analyzer’s sensitivity down to the low-ppb range is essential for meeting the stringent screening levels regulators typically apply to these compounds.

Engineering Design

The Sitelab UVF-Trilogy PAHs Analyzer shares the same rugged benchtop housing as the rest of the Trilogy family: an intuitive touch screen interface, storage for up to 18 calibrations in onboard memory, and a snap-in UV module bay so the PAHS module can be paired with GRO, EDRO, or TPH Oil modules on the same chassis. Every unit ships with a glass sample cuvette and solvent dispenser bottle included, and spare quartz cuvettes are available separately under part number QCUV-10MM. For work away from Seven Star’s client sites in Oman, the optional heavy-duty waterproof field case (part number 7200-UVFCASE) adds a rechargeable 120V battery so the Sitelab UVF-Trilogy PAHs Analyzer can be deployed to a coal ash impoundment, asphalt plant, or contaminated sediment sampling location.

Key Features

The Sitelab UVF-Trilogy PAHs Analyzer detects target PAHs at a minimum detection limit of 0.05 ppm, well into the low-ppb range regulators expect for compounds like benzo[a]pyrene. Calibration is matrix-specific—part number CAL-060M is a methanol-based kit for soil analysis and CAL-060H is a hexane-based kit for water analysis—letting the PAHS Analyzer be tuned precisely to the sample type under investigation. The touch screen interface simplifies sample measurement, calibration, and mode selection, and a full PAH screening result is available in minutes rather than the multi-week turnaround typical of outside GC/MS laboratory analysis.

Industrial Applications

Seven Star positions the Sitelab UVF-Trilogy PAHs Analyzer for fuel oil and waste oil contamination screening, asphalt and sealcoat product testing, creosote and coal tar site investigations, coal ash impoundment monitoring, and contaminated sediment and storm water runoff assessment. Oman’s road construction and asphalt production industry, along with power generation facilities handling coal ash and former manufactured gas plant sites across the GCC, all generate PAH screening requirements that the Sitelab UVF-Trilogy PAHs Analyzer can address on site rather than waiting on laboratory GC/MS confirmatory results. Marine terminal operators and port authorities investigating creosote-treated piling contamination also rely on the PAHs Analyzer to triage sediment sampling programs before committing to expensive laboratory analysis of every sample.

SpecificationDetail
Model Number7200-004-PAHS
Detection TechnologyUltraviolet fluorescence (UVF)
Target Analyte RangeTarget polycyclic aromatic hydrocarbons (PAHs), C10–C22
Minimum Detection Limit0.05 ppm
Regulated Compounds16+ EPA-regulated PAHs, including benzo[a]pyrene
Sample TypesSoil and water; fuel oils, waste oils, asphalts, creosote, coal ash, coal tars, sediment, storm water
Reference MethodsCorrelates with EPA Method 8270, other GC/MS methods, and draft Method 8670
Calibration KitsCAL-060M (methanol, soil) and CAL-060H (hexane, water)
Calibration StorageUp to 18 calibrations in onboard memory
InterfaceIntuitive touch screen
Sample AccessoriesGlass cuvette and solvent dispenser bottle included
PlatformUVF-Trilogy benchtop analyzer with snap-in PAHS UV module
Optional Field CasePart No. 7200-UVFCASE, waterproof case with rechargeable 120V battery

Because PAH contamination frequently coexists with diesel-range or oil-range hydrocarbons at the same site, the Sitelab UVF-Trilogy PAHs Analyzer’s snap-in module design lets clients add EDRO or TPH Oil modules to the same chassis, or step up to the four-module Fingerprinting Analyzer for complete forensic characterization of a mixed petroleum and PAH release. Seven Star’s technical team can help environmental consultancies in Oman and across the GCC determine the right module configuration for a given site’s contamination profile before purchase. With regional stock and engineering support in Muscat, Seven Star LLC distributes the Sitelab UVF-Trilogy to laboratories, industrial facilities, and research institutions throughout Oman, Muscat, and the Sohar and Salalah economic zones, backed by regional stock and manufacturer-standard support.

Because many PAH compounds bind tightly to soil organic matter and sediment particles, sample preparation and extraction efficiency matter as much as the analytical instrument itself. Sitelab’s calibration kits and extraction procedures for the Sitelab UVF-Trilogy PAHs Analyzer are designed around this behavior, giving consultants and laboratory technicians in Oman and the GCC a screening workflow that produces results consistent with the sample preparation practices used in confirmatory GC/MS laboratory testing, rather than a shortcut that sacrifices data quality for speed.

Request a Quote for Sitelab UVF-Trilogy PAHs Analyzer

Seven Star LLC supplies the Sitelab UVF-Trilogy PAHs Analyzer and the complete family of Sitelab UVF hydrocarbon test equipment to environmental consultants, remediation contractors, and industrial operators across Oman and the wider GCC region. For pricing, calibration kits, or technical guidance on selecting the right UVF module configuration for your PAH screening program, contact our engineering team for a tailored quotation and application support. Backed by genuine manufacturer documentation, Seven Star LLC guarantees genuine Sitelab UVF-Trilogy stock with full manufacturer warranty and regional technical support.

Other Models in the Sitelab UVF-Trilogy Analyzers Range

Seven Star LLC supplies models from the Sitelab UVF-Trilogy Analyzers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Sitelab UVF-Trilogy EDRO AnalyzerLiquid Analytical SystemsView details
Sitelab UVF-Trilogy GRO AnalyzerLiquid Analytical SystemsView details
Sitelab UVF-Trilogy PAHs AnalyzerLiquid Analytical SystemsYou are viewing this model
Sitelab UVF-Trilogy TPH Oil AnalyzerLiquid Analytical SystemsView details
Sitelab UVF-Trilogy Fingerprinting AnalyzerLiquid Analytical SystemsView details
About brand
Sitelab Corporation is a U.S.-based manufacturer specializing in portable and benchtop ultraviolet fluorescence (UVF) instruments for on-site petroleum hydrocarbon testing in soil, sediment, and water. Sitelab's UVF technology gives environmental consultants, remediation contractors, and oil and gas operators a fast, field-deployable alternative to laboratory gas chromatography, with results that correlate closely with EPA Methods 1664, 9071B, and standard GC/GC-MS test methods. The product line spans the rugged handheld UVF-500D screening analyzer to the benchtop UVF-Trilogy platform, whose interchangeable UV modules target gasoline-range, diesel-range, PAH, and total petroleum hydrocarbon contamination for underground storage tank closures, spill response, produced water compliance, and Phase II environmental site assessments. Seven Star LLC supplies genuine Sitelab hydrocarbon analyzers and calibration standards to environmental and oil and gas operators across Oman and the wider GCC region.

Frequently Asked Questions

What carbon range does the Sitelab UVF-Trilogy PAHs Analyzer detect?
The PAHs Analyzer (Model 7200-004-PAHS) detects target polycyclic aromatic hydrocarbons from C10 to C22, including the 16 EPA-regulated PAH compounds such as benzo[a]pyrene.
What is the minimum detection limit of the PAHS module?
The PAHS module has a minimum detection limit of 0.05 ppm, placing it in the low-ppb range required for regulatory PAH screening.
How do PAHs Analyzer results compare to laboratory methods?
Results compare well to EPA Method 8270 and other GC/MS test methods as the sum of the 16 regulated PAH compounds, as well as the draft Method 8670.
Which calibration kits does the PAHs Analyzer use?
Part number CAL-060M is a methanol-based kit for soil analysis and CAL-060H is a hexane-based kit for water analysis.
Is Seven Star LLC an experienced supply partner for Sitelab products?
Yes, Seven Star LLC is an experienced supplier of Sitelab, supplying genuine Sitelab UVF-Trilogy with full manufacturer warranty and technical support across Oman and the GCC.