Brand: Honeywell
Honeywell ppbRAE 3000+ Portable PID VOC Monitor
Description
Honeywell ppbRAE 3000+ portable VOC monitor: a parts-per-billion PID for hazardous areas
The ppbRAE 3000+ is a handheld photoionisation detector (PID) from the Honeywell RAE Systems range. It measures total volatile organic compounds from 1 ppb up to 10,000 ppm in a single instrument, which is why it is often chosen where one monitor must cover both trace-level screening and high-concentration leak or spill work. The datasheet describes it as a third-generation, patented PID with a 9.8 eV or 10.6 eV UV discharge lamp, a built-in datalogger and a built-in wireless modem. Seven Star LLC supplies the ppbRAE 3000+ in Oman and the GCC as an independent supplier in Muscat.
In day-to-day use the operator draws air through a flexible probe with the internal pump, reads total VOC concentration on a four-line graphic display, and sees STEL, TWA and PEAK values when exposure assessment is needed.
ppbRAE 3000+ technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Honeywell RAE Systems / ppbRAE 3000+ (datasheet DS-1018) |
| Detector | Photoionisation sensor; standard 10.6 eV lamp or optional 9.8 eV lamp |
| Measuring ranges | 0 to 9,999 ppb (1 ppb resolution); 10 to 99 ppm (0.01 ppm); 100 to 999 ppm (0.1 ppm); 1,000 to 9,999 ppm (1 ppm) |
| Response time | T90 under 3 seconds |
| Pump | Internal, integrated; flow 500 cc/min; samples from 100 ft (30 m) horizontally or vertically |
| Correction factor library | 220 compounds |
| Datalogging | 6 months at one-minute intervals as standard |
| Calibration | Two-point or three-point; memory for 8 calibration gases |
| Battery | Rechargeable external field-replaceable Li-ion pack or alkaline adapter; about 16 hours (12 hours alkaline) |
| Display | Graphic, 4 lines, 28 × 43 mm, LED backlight |
| Alarm | 95 dB buzzer at 30 cm and flashing red LED; high, low, STEL and TWA patterns |
| Dimensions / weight | 10 × 3.0 × 2.5 in (25.5 × 7.6 × 6.4 cm); 26 oz (738 g) |
| Ingress protection | IP-67 unit off, IP-65 unit running |
| Operating conditions | –20 to 50 °C; 0 to 95 % RH non-condensing |
| Hazardous-area marking | UL/cUL Class I Div 1 Groups A-D; ATEX Ex II 2G Ex ia IIC/IIB T4; IECEx Ex ia IIC/IIB T4 |
| Warranty | 3 years on the 10.6 eV lamp; 1 year on pump, battery and instrument |
Always check the nameplate of the delivered unit, because certification marks depend on the exact variant and wireless module.
How the ppbRAE 3000+ detects VOCs
A UV lamp ionises organic molecules whose ionisation energy is lower than the photon energy of the lamp, and the resulting ion current is amplified into a reading. The datasheet states the monitor uses Reflex PID technology, humidity compensation through built-in humidity and temperature sensors, and patented sensor and lamp auto-cleaning to reduce maintenance. Because PID responds to many compounds with different sensitivity, the reading is expressed in isobutylene equivalent unless a correction factor for a specific compound is selected from the built-in library of 220 compounds. A PID does not identify a compound; it responds to the total of what the lamp can ionise.
Selecting the lamp, battery and wireless module for the ppbRAE 3000+
- Lamp. The standard 10.6 eV lamp covers the broadest range of common solvents and fuel vapours. The optional 9.8 eV lamp narrows the response and can reduce interference from compounds with ionisation energies between 9.8 and 10.6 eV.
- Battery. The rechargeable Li-ion pack gives about 16 hours of operation; the alkaline adapter gives about 12 hours and is useful on remote jobs without charging.
- Wireless. The radio module supports Bluetooth, RM900 sub-1 GHz or BLE. Real-time connectivity to a command centre up to two miles (3 km) away is described with the optional RAELink3 portable modem, and typical line-of-sight ranges are given as 660 ft (200 m) for EchoView Host and 330 ft (100 m) for ProRAE Guardian with RAELink3 mesh.
- Kit. Choose the monitor-only package or the accessories kit with a hard case, charging cradle, filters and tubing, and optionally a calibration kit with 10 ppm isobutylene gas.
Calibration, bump testing and maintenance of the ppbRAE 3000+
Zero the instrument in clean air, using the organic vapour zeroing kit supplied with the monitor if the ambient air is suspect, then calibrate span with isobutylene in a Tedlar bag or from a cylinder with regulator. The instrument stores eight calibration gases, so one monitor can be used with several response factors. Replace the external filter and porous metal filters when they become dirty, clean the lamp and sensor with the supplied kit, and change the lamp at the intervals recommended by the manufacturer. The datasheet advertises tool-free access to the battery, lamp and sensor in seconds. The instrument is also compatible with the AutoRAE 2 and other RAE docking stations for bump testing and calibration records.
Where the ppbRAE 3000+ sits in the RAE portable range
Within the Honeywell portable PID range the ppbRAE 3000+ is the high-sensitivity VOC monitor. The MiniRAE 3000 and MiniRAE Lite+ are the other handheld VOC monitors, the UltraRAE 3000+ is the compound-specific model for benzene and butadiene. For mixed-gas work with LEL, oxygen and toxic sensors alongside a PID, the MultiRAE or GasAlertMicro 5 PID families apply. The ModRAE platform covers modular cartridge-based detection.
Typical ppbRAE 3000+ applications in Oman and the GCC
The datasheet lists oil and gas, HazMat, industrial safety, civil defence, and environmental and indoor air quality as application areas. In Gulf terms the monitor is used for leak surveys on flanges, valves and pump seals, confined-space pre-entry screening on tanks and vessels, fugitive emission checks around storage and loading areas, soil gas and groundwater remediation work, and industrial hygiene surveys around chemical handling. The IP-67 housing and rubber boot cope with dust, wash-down and the rough handling of turnaround work, and the 3-second response makes walk-through surveys practical in hot weather where operators need to move quickly.
Information to send with a ppbRAE 3000+ RFQ
- Target compounds and the concentration range of interest, so the lamp (9.8 eV or 10.6 eV) can be confirmed.
- Whether wireless connectivity is required and which module (Bluetooth, RM900, BLE).
- Monitor-only, accessories kit or calibration kit, and calibration gas supply arrangements.
- Required hazardous-area marking and quantity.
- Your preferred power option (Li-ion or alkaline adapter) and accessories such as a spare battery or charging cradle.
Documents and quotation for the ppbRAE 3000+
A datasheet for the ppbRAE 3000+ is attached on this page.
Send the variant and kit requirements to Seven Star LLC and we will confirm availability, lead time and any further documents for the quotation.
Other Models in the Honeywell Rae Pid Range
Seven Star LLC supplies models from the Honeywell Rae Pid range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell ppbRAE 3000+ Portable PID VOC Monitor | Fire & Gas Detectors | You are viewing this model |
| Honeywell UltraRAE 3000+ Compound-Specific PID Monitor | Fire & Gas Detectors | View details |
| Honeywell MiniRAE Lite+ Handheld PID VOC Detector | Fire & Gas Detectors | View details |
Datasheets & Documents
- Datasheet Honeywell ppbRAE 3000+ Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell ppbRAE 3000+ Portable PID VOC Monitor
Answers from our engineering team on installation, compatibility and integration.
01What measuring range does the ppbRAE 3000+ cover?
The datasheet gives 1 ppb to 10,000 ppm for VOCs, in four bands: 0 to 9,999 ppb, 10 to 99 ppm, 100 to 999 ppm and 1,000 to 9,999 ppm, with resolutions from 1 ppb to 1 ppm.
02Which lamp does the ppbRAE 3000+ use?
A 10.6 eV UV lamp is standard and a 9.8 eV lamp is optional. The 10.6 eV lamp carries a three-year warranty according to the datasheet.
03How many compounds are in the correction factor list?
The integrated correction factor list contains 220 compounds. The monitor shows gas type, correction factor and concentration on its graphic display.
04Is the ppbRAE 3000+ intrinsically safe?
The datasheet lists UL and cUL Class I Division 1 Groups A-D, ATEX Ex II 2G Ex ia IIC/IIB T4 and IECEx Ex ia IIC/IIB T4. Verify the marking on the nameplate of the unit supplied.
05How long does the battery last?
About 16 hours with the rechargeable Li-ion pack and about 12 hours with the alkaline battery adapter, according to the datasheet.


















Reviews
There are no reviews yet.