Brand: Honeywell
Honeywell FS10 Multi-Spectral IR Flame Detector
Description
Honeywell FS10 flame detector for paint spray booths and coating lines
The Honeywell FS10 is a multi-spectral infrared flame detector built for liquid paint and powder coating spray booths. It belongs to the Fire Sentry FS System 10 family, and the stand-alone version is the FS10-R Unitized detector, which meets the requirements of NFPA 33 for spray applications. Its job is to see a real fire fast, ignore the electrical arcs and hot surfaces common in finishing lines, and give a two-stage response so the process can be shut down before residues and wet paint ignite.
Seven Star LLC supplies the Honeywell FS10 in Oman and the GCC as an independent supplier in Muscat. This is a specialised detector; it suits coating and finishing installations rather than general plant areas, and we confirm the application with you before quoting.
FS10 and FS10-R: the family explained
Fire Sentry FS System 10 is a complete fire detection and process control system, with an explosion-proof detector and a wall-mounted controller in a NEMA 12 enclosure. The controller has an LCD, LED status lights and three 10-amp mechanical relays to shut down paint flow, electrostatics and the conveyor, and it can operate with one or two detectors. A card controller is also available; the manufacturer asks that you consult the factory for that.
The FS10-R Unitized detector is the stand-alone version of the same technology. It operates with any approved fire alarm panel through its ALARM, ALERT and FAULT relays, so no dedicated controller is required. Make clear in the enquiry whether you need the FS10-R stand-alone detector or the System 10 with controller.
FS10 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Honeywell / FS10 (Fire Sentry FS System 10 and FS10-R) |
| Detector type | Multi-spectral digital electro-optical infrared flame detector |
| Sensors | WideBand IR, NearBand IR and Visible |
| Spectral sensitivity | Near-band IR 0.7 to 1.1 microns; visible 400 to 700 nm; wide-band IR 0.7 to 3.5 microns |
| Field of view | 90 degrees (±45 degrees horizontal and vertical) |
| Sensitivity | Listed as 45 ft and 30 ft to a 1 sq ft gasoline fire |
| Power | 24 VDC; operating current 85 mA |
| Relay output | SPST, normally open, rated 1 A at 24 VDC; ALARM, ALERT and FAULT relays |
| Analog output | One mA output |
| Communications | RS-485 digital interface |
| Alarm response | ALERT for spray gun fireball events; FIRE ALARM declared in 4 to 5 seconds if fire continues |
| Event memory | Last six FirePic events of 8 seconds each; 200 event history entries with time and date |
| Humidity | 10 to 90% RH non-condensing |
| Minimum temperature | -40 °C |
| Enclosure material | 316 stainless steel or copper-free powder-coated aluminium |
| Ratings | NEMA 3, 4 and 4X |
| Conduit entries | 2 x 3/4 in NPT |
| Weight / size | 3.8 lb; 4.81 in diameter, 4.65 in depth |
| Mounting | Optional swivel bracket assembly |
| Warranty | 2 years from date of shipping |
How the FS10 recognises a fire
The sensor array continuously streams spectral data to a microprocessor, which compares what it sees against fire signatures instead of simply reacting to brightness. This is how the detector avoids false alarms from arcs and corona discharge, paint heaters and other background radiant sources, and how it can look through paint, powder or oil residue on its lens. Smoke and solvent mist in a liquid spray booth do not blind it either.
On power-up the detector runs a self-test and energises the FAULT relay to show healthy status, and an LED flashes every ten seconds in normal operation. A built-in through-the-lens test checks the optical path automatically. When a fireball-type event occurs at the spray gun, the ALERT relay operates; if the fire persists, the FIRE ALARM output is declared after about four to five seconds.
FirePic and SnapShot diagnostics
The detector stores pre-fire spectral data in non-volatile memory. FirePic lets you retrieve the recorded data from before an event, which helps investigators decide what caused it, and SnapShot gives a dynamic graphical display of what the detector sees. On the System 10 these records can be downloaded from the RS-232 port of the controller to a PC. This diagnostic record is valuable for insurers and for tuning booth practices after a nuisance trip.
Selection and ordering checklist for the FS10
- Stand-alone FS10-R Unitized detector or System 10 with wall-mounted controller.
- Number of detectors per booth and the required field of view coverage.
- Sensitivity setting required; the manufacturer mentions optional factory sensitivity settings and alarm outputs.
- Enclosure material: 316 stainless steel or copper-free powder-coated aluminium.
- Fire alarm panel or process controller that will take the ALARM, ALERT and FAULT relays.
- Mounting: fixed or with the optional swivel bracket.
- Spare electronics module; the listing names an electronics module for the FS10-R30 series.
Installation and maintenance of the FS10
Position each detector so the 90 degree cone covers the spray area, application zones and any points where residue builds up, and fix it firmly with the bracket aimed correctly. Wire 24 VDC and the relay circuits using the two 3/4 in NPT entries, and test that the FAULT relay shows healthy status after power-up. The detector is intended for indoor use only, per the manufacturer.
Maintenance mostly means keeping the window clean enough for the automatic lens test to pass, checking relay actions against the booth shutdown logic, and periodically exercising the system with a suitable test source. Review the stored events regularly; a pattern of ALERT events can reveal a spray gun or process problem long before a real fire.
Typical applications in Oman and the GCC
The manufacturer lists liquid paint spray lines, aerosol filling, powder coating booths and curing ovens as indoor applications. In Oman and the Gulf these appear in vehicle and equipment refinishing shops, steel fabrication and structural coating plants, furniture and aluminium joinery finishing, and pipe and valve coating lines at industrial estates. High ambient temperatures and dust inside factory buildings make a clean lens and a protected enclosure important.
Information to send with an RFQ
- Application: liquid paint, powder coating, curing oven or aerosol filling.
- Stand-alone FS10-R or full System 10 with controller.
- Number of detectors and booths.
- Fire alarm panel or shutdown system interface requirements.
- Enclosure material and mounting accessories.
- Delivery location and project timeline.
Documents and quotation
A manufacturer brochure for the Fire Sentry FS System 10 and FS10-R is attached on this page. It describes the system, operation and diagnostic features summarised above.
Send the application, version and quantity and we will confirm the exact configuration and available documents before quoting. Seven Star LLC is an independent supplier and not the manufacturer.
Datasheets & Documents
- Catalog Honeywell FS10 Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell FS10 Multi-Spectral IR Flame Detector
Answers from our engineering team on installation, compatibility and integration.
01What is the FS10 designed to detect?
It is a multi-spectral infrared flame detector for liquid paint and powder coating spray booths, using WideBand IR, NearBand IR and visible sensors to recognise fire.
02How does the FS10 respond to a fire?
It gives an ALERT output for a spray gun fireball event. If the fire continues, a FIRE ALARM is declared in 4 to 5 seconds.
03What is the field of view?
The listing gives 90 degrees, which is plus and minus 45 degrees both horizontally and vertically.
04What supply and relay ratings does the FS10-R use?
The listing shows 24 VDC power, 85 mA operating current and SPST normally open relay contacts rated 1 A at 24 VDC.
05What diagnostic data does it keep?
The FS10-R stores the last six FirePic events of 8 seconds each and 200 event history entries with time and date stamps.


















Reviews