Brand: Endress+Hauser (E & H)
Endress+Hauser Liquiline CM444 4-Channel Memosens Multiparameter Transmitter
Description
Overview of the Endress+Hauser Liquiline CM444 Four-Channel Memosens Transmitter
The Endress+Hauser Liquiline CM444 is a field transmitter for digital Memosens sensors, aimed at plants that measure several liquid parameters at one point. In the Technical Information, Endress+Hauser describes the Liquiline CM442, CM444 and CM448 as a family of multiparameter transmitters with up to eight measuring channels; the CM444 sits in the middle, with four Memosens inputs from two modules and room in its slots for current inputs and outputs, relays, digital I/O and a fieldbus module.
As the official trusted supplier and regional supplier for Endress+Hauser, Seven Star LLC proudly supplies the Endress+Hauser Liquiline CM444 to customers across the Sultanate of Oman and the wider GCC. Seven Star LLC provides the Technical Information TI00444C with each offer, so that water, wastewater and process engineers in Muscat, Sohar and Salalah can configure the module set before ordering.
Measuring System of the Endress+Hauser Liquiline CM444
The Endress+Hauser Liquiline CM444 does not measure on its own: it works with Memosens sensors and assemblies. Memosens transfers the signal digitally and contactlessly through an inductive coupling, which gives galvanic isolation, avoids contact corrosion and keeps the connection watertight, and sensors can be calibrated in the laboratory and exchanged hot as plug-and-play. The Technical Information lists measuring points for pH and ORP, conductivity (inductive and conductive), oxygen (optical and amperometric), nitrate and spectral absorption coefficient, turbidity and interface, disinfection, and ion-selective electrodes for ammonium and nitrate.
Inputs are assigned to channels in ascending slot and port order, so that "CH1: 1:1 pH glass" means channel 1 on slot 1, port 1. In the CM444 the basic module BASE2-E supplies two sensor inputs and two current outputs, and a 2DS module adds two more digital sensor inputs. An example order in the manual combines four Memosens inputs, PROFIBUS communication, a web server, two current outputs and two current inputs, with free slots left for relays or digital I/O. Mathematical functions can calculate new measured values from several channels.
Engineering Design of the Endress+Hauser Liquiline CM444
The field housing is made of flame-retardant polycarbonate with EPDM seals and stainless steel clamps, weighs about 2.1 kg, and is rated IP66/67 and NEMA Type 4X. A weather protection cover is recommended for outdoor mounting. The CM444 runs from 100 to 230 V AC or from 24 V DC, with a maximum consumption of 73 VA or 68 W, and the permitted ambient temperature is generally –20 to +55 °C. A 240 × 160 pixel transflective graphic display with a red alarm background is operated by a navigator and soft keys.
Communication options are HART, PROFIBUS DP, Modbus TCP or RS485, PROFINET and EtherNet/IP, with one active fieldbus at a time selected by an activation code, plus an integrated web server for full access to configuration, measured values and diagnostics. With the Ethernet functions via the base module, up to six current outputs can run in parallel in the CM444. A data logbook stores measured values in non-volatile memory and exports to SD card or Ethernet and the Field Data Manager software.
Key Features of the Endress+Hauser Liquiline CM444
This transmitter offers the following capabilities according to the manufacturer’s documentation:
- Four digital Memosens measuring channels in a single field transmitter, with a modular concept for further inputs and outputs.
- Measurement of pH, ORP, conductivity, oxygen, turbidity, nitrate, SAC, chlorine and ions with matching Memosens sensors.
- Choice of cleaning function, controller and alarm relay, with relay modules of two or four contacts.
- Optional current inputs and outputs, digital inputs and outputs, with a limit of eight current inputs and outputs in total.
- Fieldbus options of HART, PROFIBUS DP, Modbus, PROFINET and EtherNet/IP, with a built-in web server.
- Heartbeat diagnostics that grade the health of the device and the condition of the sensor in line with NAMUR categories.
- Measuring range switching for conductivity through digital inputs or fieldbus, using an upgrade code.
- Hardware upgrade kits to extend a Liquiline to more channels without replacing the basic device.
Industrial Applications of the Endress+Hauser Liquiline CM444
The Endress+Hauser Liquiline CM444 is used where several parameters must be monitored and controlled together, such as pH, conductivity and turbidity in water treatment, nitrate, ammonium and oxygen in aeration basins of wastewater plants, chlorine and pH in drinking water, and cooling-water conductivity in power plants. In the Sultanate of Oman, typical sites include desalination and reverse osmosis plants, municipal and industrial wastewater treatment, district cooling and utility systems in the Sohar and Salalah economic zones, and food, beverage and chemical production.
Seven Star LLC supplies the Liquiline platform throughout Oman and the GCC. Buyers can compare the two-channel Endress+Hauser Liquiline CM442 and the Liquiline M CM42, or add the
as a typical sensor.Technical Specifications of the Endress+Hauser Liquiline CM444
The table summarizes the main data of the Endress+Hauser Liquiline CM444 from Endress+Hauser Technical Information TI00444C.
| Parameter | Specification |
|---|---|
| Model | Endress+Hauser Liquiline CM444 |
| Sensor technology | Digital Memosens sensors |
| Memosens inputs | 4 (2 on BASE2-E module plus 2DS module) |
| Fieldbus options | HART, PROFIBUS DP, Modbus TCP/RS485, PROFINET, EtherNet/IP |
| Supply voltage | 100 to 230 V AC or 24 V DC |
| Power consumption | Max. 73 VA (AC); max. 68 W (24 V DC) |
| Ambient temperature | Generally –20 to +55 °C |
| Degree of protection | IP66/67, NEMA Type 4X |
| Display | Graphic, 240 × 160 pixel, backlit |
| Weight | Approx. 2.1 kg |
| Data storage | Data logbook, SD card, Ethernet, Field Data Manager |
Planning the four measuring points
List the sensor type at each measuring point and identify the current outputs, relays and fieldbus needed by the control system. For an expansion, include the existing module layout so the input and output modules can be matched to the available slots.
CM444 manufacturer technical reference
Request a Quote for Endress+Hauser Liquiline CM444
To order the Endress+Hauser Liquiline CM444, send Seven Star LLC the parameters to be measured, the Memosens sensors, required relays, current outputs and fieldbus so that we can prepare a formal RFQ. The Technical Information TI00444C can be downloaded from this page, and our instrumentation division will help you choose the module set and confirm lead time at quotation. In Oman and the GCC, we supply the Endress+Hauser Liquiline CM444 with manufacturer documentation and local support.
Datasheets & Documents
- Datasheet Endress+Hauser Liquiline CM444 Technical Information (TI00444C, CM442/CM444/CM448) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser Liquiline CM444 4-Channel Memosens
Answers from our engineering team on installation, compatibility and integration.
01What is the Endress+Hauser Liquiline CM444?
It is a field transmitter for digital Memosens sensors with four measuring channels, for pH, ORP, conductivity, oxygen, turbidity, nitrate and other liquid analysis parameters.
02Which sensors can be connected to the Liquiline CM444?
Memosens sensors such as pH, ORP, conductive and inductive conductivity, optical and amperometric oxygen, turbidity, nitrate and SAC, chlorine and ion-selective sensors.
03Which communication protocols does the CM444 support?
HART, PROFIBUS DP, Modbus TCP or RS485, PROFINET and EtherNet/IP, with one fieldbus active at a time, plus an integrated web server.
04What are the power supply and protection ratings of the CM444?
It runs from 100 to 230 V AC or 24 V DC, is rated IP66/67 and NEMA Type 4X, and is generally specified for ambient temperatures of -20 to +55 °C.
05Is Seven Star LLC a trusted supplier for Endress+Hauser products?
Yes. Seven Star LLC is a trusted supplier of Endress+Hauser products, supplying instrumentation across Oman and the GCC, with genuine documentation and local technical support.


















Reviews