Brand: AUMA
AUMA SQR 12.2 Modulating Part-Turn Actuator
Description
Overview
AUMA SQR 12.2 is the modulating version of the high-torque SQ 12.2 and offers a tripping torque of 600 Nm to 1,200 Nm. The maximum modulating torque is 600 Nm at S4 – 25 % and 420 Nm at S4 – 50 %, figures that make it suitable for large control butterfly valves in water transmission and cooling circuits. The minimum tripping setting of 600 Nm is double that of the SQR 10.2, which tells you the frame is not meant for light valves.
Seven Star LLC supplies the AUMA SQR 12.2 throughout Oman and the GCC. Large control valves are long-lead items, so we work with customers in Muscat, Sohar and Salalah early to align the actuator, controls and valve documentation.
Slow, Precise Motion at High Torque
Large valves in a control loop need both muscle and finesse. The AUMA SQR 12.2 provides operating times of 16, 22, 32, 45, 63, 84 and 125 seconds for 90 degrees at 50 Hz. At the fastest 16 s ratio the figures are reduced: tripping torque is limited to 900 Nm, S4 – 50 % maximum to 630 Nm and modulating torque to 450 Nm at S4 – 25 % and 315 Nm at S4 – 50 %. From 22 s and slower the full ratings of 1,200 Nm, 840 Nm, 600 Nm and 420 Nm apply.
The minimum pulse on reversal ranges from 180 ms at 16 s to 1,100 ms at 125 s, so a slower ratio gives a coarser minimum correction. With 1,500 permitted starts per hour and a 50 ms same-direction pulse, the drive can follow a controller smoothly, but designers should choose the slowest ratio the process allows to reduce wear and avoid hunting. The S4 – 50 % option is available at every ratio of this frame.
Engineering Design of the AUMA SQR 12.2
The coupling of the AUMA SQR 12.2 takes shafts up to 50 mm cylindrical, 36 mm square and 41 mm two-flat, and the standard F12 flange with F14 option matches large butterfly valve bodies. The 200 mm handwheel needs 22 or 30 turns for a quarter turn, so manual positioning is deliberate and slow, a trait that suits setting and emergency use.
Weight is approximately 35 kg for the standard unit and 43 kg with base and lever, so lifting equipment is recommended. IP68 enclosure protection and KS corrosion protection are standard. The AUMA data reviewed for this frame covers 3-phase and 1-phase AC supply, and the unit pairs with AM or AC controls to provide the analogue or fieldbus positioning interface the loop requires.
Key Features
The AUMA SQR 12.2 brings modulating duty to the large-valve end of the SQ .2 range.
- A tripping torque of 600 Nm to 1,200 Nm with up to 600 Nm modulating torque suits large control valves.
- Seven operating times from 16 s to 125 s allow gentle control of big pipelines.
- A reduced rating at 16 s (900 Nm trip, 450 Nm modulating) is clearly documented, so the speed choice can be made safely.
- Up to 1,500 starts per hour and a 50 ms pulse enable responsive positioning.
- F12/F14 flanges and 50 mm shafts match large butterfly valve interfaces.
- A 200 mm handwheel with 22 or 30 turns gives controlled manual operation.
- IP68 and KS protection suit marine and desert environments.
- AM and AC controls add fieldbus, data logging and diagnostics.
Selection Guidance for the AUMA SQR 12.2
For the AUMA SQR 12.2, the main sizing check is the modulating torque of 600 Nm at S4 – 25 %, which should exceed the valve’s torque under flow with margin. A large butterfly valve under high differential pressure can see a torque peak somewhere in mid-travel, and if that peak is close to the modulating limit, the S4 – 25 % duty rating is at risk.
Tune the controller conservatively. The minimum reversal pulse of 180 ms to 1,100 ms indicates how long the motor must be powered before the output moves, so a controller deadband narrower than the actuator’s step resolution will cause hunting.
Industrial Applications
The AUMA SQR 12.2 is used on control butterfly valves in seawater intake and discharge systems, large chilled-water headers, and water treatment plant inlet control. Power stations use it for cooling-water flow regulation and turbine hall auxiliary systems. Because it holds position with a self-locking gear train and corrects in small steps, it is a good match for pressure-control valves that must hold a setpoint through changing demand.
In Oman and the GCC, Seven Star LLC delivers the SQR 12.2 to EPC contractors, utilities and industrial operators across the GCC.
Next to it in the range are the AUMA SQR 10.2 and AUMA SQR 14.2.
For open-close valves see the AUMA SQ part-turn actuator range, for torque beyond this range see the AUMA GS part-turn gearboxes, and for integral controls see the AUMA MATIC AM/AC integral actuator controls.
Technical Specifications
The following data is AUMA’s published specification for the AUMA SQR 12.2 with a 3-phase AC motor in modulating duty.
| Parameter | Specification |
|---|---|
| Model | AUMA SQR 12.2 (3-phase AC, AUMA NORM) |
| Tripping torque range | 600 Nm – 1,200 Nm (900 Nm maximum at 16 s); S4 – 50 % option up to 840 Nm (630 Nm at 16 s) |
| Modulating torque, max. | 600 Nm at S4 – 25 %, 420 Nm at S4 – 50 % (450 / 315 Nm at 16 s) |
| Operating times for 90° | 16 – 125 s at 50 Hz (12 – 108 s at 60 Hz) |
| Number of starts | 1,500 per hour maximum |
| Pulse duration on reversal | 180 ms – 1,100 ms depending on speed |
| Pulse duration, same direction | 50 ms |
| Valve attachment (EN ISO 5211) | F12 standard, F14 option |
| Valve shaft, max. | 50 mm cylindrical, 36 mm square, 41 mm two-flat |
| Handwheel | Ø 200 mm, 22 or 30 turns for 90° |
| Weight, approx. | 35 kg (43 kg with base and lever) |
| Type of duty | Intermittent duty S4 – 25 %, class C (S4 – 50 % option) |
| Swing angle | 75° to below 105° (standard) |
| Enclosure protection | IP68 |
| Corrosion protection | KS (KX option) |
| Ambient temperature | -30 °C to +70 °C (standard) |
Request a Quote for AUMA SQR 12.2
To receive a quotation for the AUMA SQR 12.2, send Seven Star LLC the valve datasheet, the running and seat torque, the required stroke time and the control signal. We will prepare a formal offer with stock information, and the technical data sheet is linked on this page. In Oman and the GCC, we support each AUMA SQR 12.2 with advice from our instrumentation division.
Datasheets & Documents
- Datasheet AUMA SQR 05.2 - SQR 14.2 Technical Data (3-phase AC, modulating duty) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SQR 12.2 Modulating Part-Turn Actuator
Answers from our engineering team on installation, compatibility and integration.
01What is special about the 16 second ratio of the AUMA SQR 12.2?
At 16 s AUMA limits the maximum tripping torque to 900 Nm and the modulating torque to 450 Nm at S4 - 25 %. Slower ratios release the full 1,200 Nm and 600 Nm.
02What is the slowest operating time of the AUMA SQR 12.2?
The slowest ratio is 125 seconds for 90 degrees at 50 Hz. The minimum reversal pulse at that ratio is 1,100 ms.
03What valve interface does the AUMA SQR 12.2 provide?
The standard flange is EN ISO 5211 F12 with F14 as an option, and the coupling takes shafts up to 50 mm cylindrical, 36 mm square or 41 mm two-flat.
04How heavy is the AUMA SQR 12.2?
About 35 kg with unbored coupling and handwheel and about 43 kg with base and lever. Use lifting aids on elevated platforms.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every actuator is genuine AUMA product supplied with correct documentation and local technical support.